Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Bestcold vs K&A: heat pump ratings compared
Against heat pumps of the same size and type, a typical Bestcold model beats 46% and a typical K&A model 30%. Bestcold rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Bestcold
46%
of similar heat pumps beaten by its typical model
About average79 models listed
K&A
30%
of similar heat pumps beaten by its typical model
Well below average23 models listed
- Efficiency on a 5°F dayCOP at 5°FBestcold: Beats 45%K&A: Beats 31%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBestcold: Beats 43%K&A: Beats 39%
- Winter-long heating efficiencyHSPF2Bestcold: Beats 48%K&A: Beats 33%
- Summer-long cooling efficiencySEER2Bestcold: Beats 51%K&A: Beats 27%
- Hot-day cooling efficiencyEER2Bestcold: Beats 39%K&A: Beats 28%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Bestcold
- 68%
- K&A
- 17%
Xcel CC
- Bestcold
- 66%
- K&A
- 17%
CEE Advanced
- Bestcold
- 1%
- K&A
- 0%
ENERGY STAR CC
- Bestcold
- 10%
- K&A
- 0%
All-around best, ductless up to 1.5 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Bestcold
- 1MYTW18NA23BCH24-OBestcold1.5 tons · 18,000 Btu/h · DuctlessCold-climate pick, score 68.6Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 80% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Great
- Cooling efficiency
- 24.0 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Good
- 2MYTW12NA23BCH24ES-Owith ductless indoor unit MYTD12NA23BCH24ES-IBestcoldAlso listed as MYTD12NA23BCH24-O1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 59.5Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 24.0 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Good
- 3MYTW12NA13BCH24ES-Owith ductless indoor unit MYTD12NA13BCH24ES-IBestcoldAlso listed as MYTD12NA13BCH24-O1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 58.9Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 23.0 (SEER2)
- Good
- Hot-day cooling
- 13.0 (EER2)
- Good
K&A
- 1MAJESTIC-12K110V-S2with ductless indoor unit MAJESTIC-12K110V-S2K&A1 ton · 11,500 Btu/h · DuctlessNot a cold-climate pick: keeps 69% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 17.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.5 (EER2)
- Below the middle
- 2MAJESTIC-18K220V-S2with ductless indoor unit MAJESTIC-18K220V-S2K&A1.5 tons · 17,000 Btu/h · DuctlessNot a cold-climate pick: keeps 57% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 58% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 17.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.5 (EER2)
- Below the middle
- 3MAJESTIC-12K220V-S2with ductless indoor unit MAJESTIC-12K220V-S2K&A1 ton · 11,500 Btu/h · DuctlessNot a cold-climate pick: keeps 60% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 61% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.75 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 17.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.5 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view