Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
BULLETPROOF AC vs First Co.: heat pump ratings compared
Against heat pumps of the same size and type, a typical BULLETPROOF AC model beats 44% and a typical First Co. model 11%. BULLETPROOF AC rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
BULLETPROOF AC
44%
of similar heat pumps beaten by its typical model
Below average21 models listed
First Co.
11%
of similar heat pumps beaten by its typical model
Well below average21 models listed
- Efficiency on a 5°F dayCOP at 5°FBULLETPROOF AC: Beats 55%First Co.: Beats 34%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBULLETPROOF AC: Beats 39%First Co.: Beats 12%
- Winter-long heating efficiencyHSPF2BULLETPROOF AC: Beats 42%First Co.: Beats 1%
- Summer-long cooling efficiencySEER2BULLETPROOF AC: Beats 40%First Co.: Beats 0%
- Hot-day cooling efficiencyEER2BULLETPROOF AC: Beats 44%First Co.: Beats 12%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- BULLETPROOF AC
- 38%
- First Co.
- 0%
Xcel CC
- BULLETPROOF AC
- 38%
- First Co.
- 0%
CEE Advanced
- BULLETPROOF AC
- 0%
- First Co.
- 0%
ENERGY STAR CC
- BULLETPROOF AC
- 0%
- First Co.
- 0%
All-around best, ducted 2 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
BULLETPROOF AC
- 1BPAC2TCwith ducted air handler BPAC2TAHBULLETPROOF ACAlso listed as BPAC2THP20S2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 67.2Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 9.4 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 13.3 (EER2)
- Top 10%
- 2BPAC2THP14Swith ducted air handler BPAC2TAH14SBULLETPROOF AC2 tons · 23,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 52% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 7.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 14.3 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Below the middle
- 3BPAC2TPUHP15SBULLETPROOF AC2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 25.4Meets none of the standards tracked here
- Heat kept at 5°F
- 77% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.64 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.2 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 9.9 (EER2)
- Below the middle
First Co.
- 124WHHPBAwith ducted air handler 37CLX(*,Q,W)First Co.2 tons · 23,000 Btu/h · DuctedNot a cold-climate pick: keeps 56% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 55% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.8 (HSPF2)
- Below the middle
- Cooling efficiency
- 13.5 (SEER2)
- Below the middle
- Hot-day cooling
- 12.0 (EER2)
- Good
- 2EHE24***D***BFirst Co.Also listed as EHE24***E***B2 tons · 24,400 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 51% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 6.3 (HSPF2)
- Below the middle
- Cooling efficiency
- 11.9 (SEER2)
- Below the middle
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
- 3EHE30***D***BFirst Co.Also listed as EHE30***E***B2 tons · 26,400 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 51% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.3 (HSPF2)
- Below the middle
- Cooling efficiency
- 11.9 (SEER2)
- Below the middle
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view