CLASSIC vs DUOHOME: heat pump ratings compared
Against heat pumps of the same size and type, a typical CLASSIC model beats 41% and a typical DUOHOME model 57%. DUOHOME rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
CLASSIC
41%
of similar heat pumps beaten by its typical model
Below average40 models listed
DUOHOME
57%
of similar heat pumps beaten by its typical model
Above average39 models listed
- Efficiency on a 5°F dayCOP at 5°FCLASSIC: Beats 37%DUOHOME: Beats 61%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCLASSIC: Beats 43%DUOHOME: Beats 48%
- Winter-long heating efficiencyHSPF2CLASSIC: Beats 37%DUOHOME: Beats 66%
- Summer-long cooling efficiencySEER2CLASSIC: Beats 45%DUOHOME: Beats 63%
- Hot-day cooling efficiencyEER2CLASSIC: Beats 40%DUOHOME: Beats 47%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- CLASSIC
- 65%
- DUOHOME
- 87%
Xcel CC
- CLASSIC
- 65%
- DUOHOME
- 74%
CEE Advanced
- CLASSIC
- 3%
- DUOHOME
- 0%
ENERGY STAR CC
- CLASSIC
- 20%
- DUOHOME
- 0%
All-around best, ducted 2.5–3 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 2.5–3 tons (27,000–38,999 Btu/h cooling). What size is my system?
CLASSIC
- 1GMRSHC36AS4CLASSIC3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 52.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 11.7 (EER2)
- Good
- 2TMRHC36AS4CLASSIC3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 47.5Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
DUOHOME
- 1D5OD30-36HFN10-M1-DDUOHOMEAlso listed as D5OD30-36HFN10-M1D-D3 tons · 35,000 Btu/h · DuctedCold-climate pick, score 60.6Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 9.2 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Good
- 2DOX630-36HFN10-M3Xwith ducted air handler DVBC-36HWFN10-MC3E-DDUOHOME3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 73.1Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 105% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.3 (HSPF2)
- Top 10%
- Cooling efficiency
- 17.4 (SEER2)
- Good
- Hot-day cooling
- 11.7 (EER2)
- Good
- 3DOD30-30HFN10-M3Xwith ducted air handler DVBC-30HWFN10-MC3E-DDUOHOME2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 68.7Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 96% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.96 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 16.8 (SEER2)
- Good
- Hot-day cooling
- 11.7 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.