CLASSIC vs DUOHOME: heat pump ratings compared
Against heat pumps of the same size and type, a typical CLASSIC model beats 41% and a typical DUOHOME model 57%. DUOHOME rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
CLASSIC
41%
of similar heat pumps beaten by its typical model
Below average40 models listed
DUOHOME
57%
of similar heat pumps beaten by its typical model
Above average39 models listed
- Efficiency on a 5°F dayCOP at 5°FCLASSIC: Beats 37%DUOHOME: Beats 61%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCLASSIC: Beats 43%DUOHOME: Beats 48%
- Winter-long heating efficiencyHSPF2CLASSIC: Beats 37%DUOHOME: Beats 66%
- Summer-long cooling efficiencySEER2CLASSIC: Beats 45%DUOHOME: Beats 63%
- Hot-day cooling efficiencyEER2CLASSIC: Beats 40%DUOHOME: Beats 47%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- CLASSIC
- 65%
- DUOHOME
- 87%
Xcel CC
- CLASSIC
- 65%
- DUOHOME
- 74%
CEE Advanced
- CLASSIC
- 3%
- DUOHOME
- 0%
ENERGY STAR CC
- CLASSIC
- 20%
- DUOHOME
- 0%
All-around best, ducted up to 1.5 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
CLASSIC
- 1TMRHC18AS2CLASSIC1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 44.0Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 22.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Good
- 2GMRSHC18AS2CLASSIC1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 39.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 76% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.86 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 11.7 (EER2)
- Good
DUOHOME
- 1DOX230-09HFN10-M1with ducted air handler DTJ-09HWFN10-M1-DDUOHOME1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 81.3Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.32 (COP at 5°F)
- Great
- Winter efficiency
- 11.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.7 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Great
- 2DOX430-18HFN10-M1with ducted air handler DTJ-18HWFN10-M1-DDUOHOME1.5 tons · 17,500 Btu/h · DuctedCold-climate pick, score 69.8Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Winter efficiency
- 11.3 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 13.3 (EER2)
- Top 10%
- 3D3OX430-18HFN10-M1-DDUOHOME1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 72.6Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 77% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Good