Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Cooper&Hunter vs PolarWave: heat pump ratings compared
Against heat pumps of the same size and type, a typical Cooper&Hunter model beats 64% and a typical PolarWave model 51%. Cooper&Hunter rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Cooper&Hunter
64%
of similar heat pumps beaten by its typical model
Well above average63 models listed
PolarWave
51%
of similar heat pumps beaten by its typical model
About average20 models listed
- Efficiency on a 5°F dayCOP at 5°FCooper&Hunter: Beats 65%PolarWave: Beats 52%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCooper&Hunter: Beats 62%PolarWave: Beats 44%
- Winter-long heating efficiencyHSPF2Cooper&Hunter: Beats 73%PolarWave: Beats 58%
- Summer-long cooling efficiencySEER2Cooper&Hunter: Beats 65%PolarWave: Beats 57%
- Hot-day cooling efficiencyEER2Cooper&Hunter: Beats 58%PolarWave: Beats 42%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Cooper&Hunter
- 86%
- PolarWave
- 75%
Xcel CC
- Cooper&Hunter
- 73%
- PolarWave
- 65%
CEE Advanced
- Cooper&Hunter
- 8%
- PolarWave
- 0%
ENERGY STAR CC
- Cooper&Hunter
- 71%
- PolarWave
- 70%
Top cold-climate picks, ductless up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Cooper&Hunter
- 1CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VICooper&Hunter0.5 tons · 6,000 Btu/h · DuctlessKeeps 110% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 110% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.40 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 14.8 (HSPF2)
- Top 10%
- 2CH-RES09-230VOwith ductless indoor unit CH-RSH09MMCCooper&Hunter1 ton · 9,000 Btu/h · DuctlessKeeps 96% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 96% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.27 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.9 (HSPF2)
- Top 10%
- 3CH-RES18-230VOwith ductless indoor unit CH-RSH16MMCCooper&Hunter1.5 tons · 16,000 Btu/h · DuctlessKeeps 77% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 77% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.16 (COP at 5°F)
- Great
- Seasonal efficiency
- 13.5 (HSPF2)
- Top 10%
PolarWave
- 1EZ-18ZPL-HP230Bwith ductless indoor unit EZ-18W-MBPolarWave1.5 tons · 18,000 Btu/h · DuctlessKeeps 71% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.44 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 11.5 (HSPF2)
- Top 10%
- 2EZ-18Z-M2BPolarWave1.5 tons · 18,000 Btu/h · DuctlessKeeps 74% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.31 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 10.0 (HSPF2)
- Good
- 3EZ-12ZPL-HP115Bwith ductless indoor unit EZ-12WPL-HP115BPolarWave1 ton · 12,000 Btu/h · DuctlessKeeps 70% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.09 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.2 (HSPF2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view