Skip to content

Custom Comfort vs Panasonic: heat pump ratings compared

Against heat pumps of the same size and type, a typical Custom Comfort model beats 65% and a typical Panasonic model 47%. Custom Comfort rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

Custom Comfort

65%

of similar heat pumps beaten by its typical model

Well above average

20 models listed

Panasonic

47%

of similar heat pumps beaten by its typical model

About average

36 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCustom Comfort: Beats 50%Panasonic: Beats 40%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCustom Comfort: Beats 83%Panasonic: Beats 50%
  • Winter-long heating efficiencyHSPF2Custom Comfort: Beats 84%Panasonic: Beats 57%
  • Summer-long cooling efficiencySEER2Custom Comfort: Beats 65%Panasonic: Beats 48%
  • Hot-day cooling efficiencyEER2Custom Comfort: Beats 51%Panasonic: Beats 39%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Custom Comfort
    75%
    Panasonic
    53%
  • Xcel CC

    Custom Comfort
    85%
    Panasonic
    36%
  • CEE Advanced

    Custom Comfort
    5%
    Panasonic
    0%
  • ENERGY STAR CC

    Custom Comfort
    100%
    Panasonic
    36%

All-around best, ducted 2.5–3 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Showing Ducted, 2.5–3 tons (27,000–38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

Custom Comfort

  1. 1CCOXHAMZ327HPCustom Comfort2.5 tons · 27,000 Btu/h · DuctedCold-climate pick, score 80.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    101% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.8 (EER2)
    Great
    81.9score / 100Heating 80 · Cooling 83
  2. 2CCOXHAMZ436HPCustom Comfort3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 63.7Meets none of the standards tracked here
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.70 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.7 (EER2)
    Good
    71.2score / 100Heating 64 · Cooling 79
  3. 3CCOXHASZ36CHPwith ducted air handler CCOXHASD36Custom Comfort3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 79.9Meets ENERGY STAR CC
    Heat kept at 5°F
    86% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.98 (COP at 5°F)
    Good
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    16.5 (SEER2)
    Good
    Hot-day cooling
    9.0 (EER2)
    Below the middle
    58.3score / 100Heating 80 · Cooling 37

Panasonic

  1. 1CU-HE36YAHK6with ducted air handler CS-HE36YAHK6Panasonic3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 78.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    86% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.97 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    56.1score / 100Heating 75 · Cooling 38
  2. 2CU-HE30YAHK6with ducted air handler CS-HE30YAC6Panasonic2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 67.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.7 (HSPF2)
    Great
    Cooling efficiency
    15.5 (SEER2)
    Below the middle
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    52.6score / 100Heating 68 · Cooling 37
  3. 3CU-E36YAHK6with ducted air handler CS-HE36YAHK6Panasonic3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 58% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    58% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Good
    Winter efficiency
    8.5 (HSPF2)
    Good
    Cooling efficiency
    16.9 (SEER2)
    Good
    Hot-day cooling
    10.1 (EER2)
    Below the middle
    46.5score / 100Heating 47 · Cooling 46

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view