Skip to content

DIYCOOL vs Maestrale: heat pump ratings compared

Against heat pumps of the same size and type, a typical DIYCOOL model beats 54% and a typical Maestrale model 64%. Maestrale rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

DIYCOOL

54%

of similar heat pumps beaten by its typical model

About average

24 models listed

Maestrale

64%

of similar heat pumps beaten by its typical model

Well above average

24 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FDIYCOOL: Beats 53%Maestrale: Beats 29%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FDIYCOOL: Beats 51%Maestrale: Beats 72%
  • Winter-long heating efficiencyHSPF2DIYCOOL: Beats 63%Maestrale: Beats 71%
  • Summer-long cooling efficiencySEER2DIYCOOL: Beats 60%Maestrale: Beats 79%
  • Hot-day cooling efficiencyEER2DIYCOOL: Beats 47%Maestrale: Beats 61%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    DIYCOOL
    79%
    Maestrale
    100%
  • Xcel CC

    DIYCOOL
    71%
    Maestrale
    100%
  • CEE Advanced

    DIYCOOL
    4%
    Maestrale
    0%
  • ENERGY STAR CC

    DIYCOOL
    75%
    Maestrale
    33%

All-around best, ductless 2 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

DIYCOOL

  1. 1EZ-24ZPL-HP230Bwith ductless indoor unit EZ-24W-MBDIYCOOL2 tons · 24,000 Btu/h · DuctlessNot a cold-climate pick: keeps 67% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    22.7 (SEER2)
    Good
    Hot-day cooling
    12.7 (EER2)
    Good
    56.2score / 100Heating 38 · Cooling 74
  2. 2EZ-27Z-M3BDIYCOOL2 tons · 26,000 Btu/h · DuctlessCold-climate pick, score 42.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.0 (HSPF2)
    Below the middle
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Good
    50.4score / 100Heating 33 · Cooling 68
  3. 3EZ-24Z-HP230Bwith ductless indoor unit EZ-24W-HP230BDIYCOOL2 tons · 24,000 Btu/h · DuctlessNot a cold-climate pick: keeps 68% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    68% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.08 (COP at 5°F)
    Good
    Winter efficiency
    8.7 (HSPF2)
    Below the middle
    Cooling efficiency
    18.9 (SEER2)
    Below the middle
    Hot-day cooling
    9.7 (EER2)
    Below the middle
    26.1score / 100Heating 36 · Cooling 17

Maestrale

  1. 1TSA24MAQU1J0X24-Owith ductless indoor unit TSA24MAQU1J0X24-IMaestraleAlso listed as TSA24MAQU1JOX24-0, TSA24MAQU1J0X24-0, TSA24MAQU1J0X24-O2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 58.0Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    93% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    22.5 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    56.1score / 100Heating 58 · Cooling 54

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view