Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
GCHV vs KeplerX: heat pump ratings compared
Against heat pumps of the same size and type, a typical GCHV model beats 38% and a typical KeplerX model 42%. KeplerX rates slightly higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
GCHV
38%
of similar heat pumps beaten by its typical model
Well below average20 models listed
KeplerX
42%
of similar heat pumps beaten by its typical model
Below average20 models listed
- Efficiency on a 5°F dayCOP at 5°FGCHV: Beats 39%KeplerX: Beats 34%
- Heating power kept at 5°FCapacity at 5°F vs 47°FGCHV: Beats 37%KeplerX: Beats 41%
- Winter-long heating efficiencyHSPF2GCHV: Beats 28%KeplerX: Beats 52%
- Summer-long cooling efficiencySEER2GCHV: Beats 30%KeplerX: Beats 58%
- Hot-day cooling efficiencyEER2GCHV: Beats 51%KeplerX: Beats 26%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- GCHV
- 20%
- KeplerX
- 35%
Xcel CC
- GCHV
- 20%
- KeplerX
- 25%
CEE Advanced
- GCHV
- 0%
- KeplerX
- 0%
ENERGY STAR CC
- GCHV
- 10%
- KeplerX
- 0%
All-around best, ducted 3.5–4.5 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 3.5–4.5 tons (39,000–56,999 Btu/h cooling). What size is my system?
GCHV
- 1COT-D60HNR8-GA01(J0)with ducted air handler CAH-D48HNR8-FMD(J0)GCHV4 tons · 47,500 Btu/h · DuctedCold-climate pick, score 64.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 17.5 (SEER2)
- Good
- Hot-day cooling
- 11.3 (EER2)
- Good
- 2COT-D48HNR8-GA01(J0)with ducted air handler CAH-D60HNR8-FMD(J0)GCHV4.5 tons · 55,500 Btu/h · DuctedCold-climate pick, score 64.7Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 8.6 (HSPF2)
- Good
- Cooling efficiency
- 17.0 (SEER2)
- Good
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
KeplerX
- 1K18HVH48WD2RKeplerX4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 60.3Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 93% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 11.2 (EER2)
- Good
- 2K18HVH60WD2RKeplerX4.5 tons · 55,000 Btu/h · DuctedCold-climate pick, score 56.9Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.82 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 18.5 (SEER2)
- Great
- Hot-day cooling
- 10.6 (EER2)
- Below the middle
- 3K20HVH48WD2VN3with ducted air handler K20HVH48WD2HN3KeplerX4 tons · 48,000 Btu/h · DuctedNot a cold-climate pick: keeps 60% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 60% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.35 (COP at 5°F)
- Great
- Winter efficiency
- 8.1 (HSPF2)
- Good
- Cooling efficiency
- 18.5 (SEER2)
- Great
- Hot-day cooling
- 9.7 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view