Skip to content

Kerr vs Mirage: heat pump ratings compared

Against heat pumps of the same size and type, a typical Kerr model beats 66% and a typical Mirage model 48%. Kerr rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Kerr

66%

of similar heat pumps beaten by its typical model

Well above average

38 models listed

Mirage

48%

of similar heat pumps beaten by its typical model

About average

34 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FKerr: Beats 59%Mirage: Beats 43%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FKerr: Beats 77%Mirage: Beats 41%
  • Winter-long heating efficiencyHSPF2Kerr: Beats 78%Mirage: Beats 50%
  • Summer-long cooling efficiencySEER2Kerr: Beats 64%Mirage: Beats 56%
  • Hot-day cooling efficiencyEER2Kerr: Beats 62%Mirage: Beats 37%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Kerr
    79%
    Mirage
    77%
  • Xcel CC

    Kerr
    90%
    Mirage
    65%
  • CEE Advanced

    Kerr
    3%
    Mirage
    0%
  • ENERGY STAR CC

    Kerr
    90%
    Mirage
    38%

All-around best, ductless 2 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Kerr

  1. 1A-KHP24SA-1with ductless indoor unit B-KHP24SA-1KerrAlso listed as A-ZKP24SA-12 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 89.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.34 (COP at 5°F)
    Top 10%
    Winter efficiency
    13.5 (HSPF2)
    Top 10%
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    13.0 (EER2)
    Great
    76.4score / 100Heating 88 · Cooling 65
  2. 2A-KSP24SA-1with ductless indoor unit B-KSP24SA-1Kerr2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 38.9Meets Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.01 (COP at 5°F)
    Good
    Winter efficiency
    8.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.0 (EER2)
    Below the middle
    20.9score / 100Heating 39 · Cooling 3

Mirage

  1. 1OMZH241Cwith ductless indoor unit CGFH241CMirage2 tons · 23,000 Btu/h · DuctlessCold-climate pick, score 62.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.4 (HSPF2)
    Great
    Cooling efficiency
    22.5 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    58.4score / 100Heating 63 · Cooling 54
  2. 2OMZH241C*with ductless indoor unit IMZH241CMirage2 tons · 23,000 Btu/h · DuctlessCold-climate pick, score 36.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    74% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    48.3score / 100Heating 37 · Cooling 60
  3. 3OPWH241Cwith ductless indoor unit OPWH241CMirageAlso listed as OPWH241C2 tons · 24,000 Btu/h · DuctlessNot a cold-climate pick: keeps 65% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    65% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    39.1score / 100Heating 43 · Cooling 35

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view