Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Kerr vs Mirage: heat pump ratings compared
Against heat pumps of the same size and type, a typical Kerr model beats 66% and a typical Mirage model 48%. Kerr rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Kerr
66%
of similar heat pumps beaten by its typical model
Well above average38 models listed
Mirage
48%
of similar heat pumps beaten by its typical model
About average34 models listed
- Efficiency on a 5°F dayCOP at 5°FKerr: Beats 59%Mirage: Beats 43%
- Heating power kept at 5°FCapacity at 5°F vs 47°FKerr: Beats 77%Mirage: Beats 41%
- Winter-long heating efficiencyHSPF2Kerr: Beats 78%Mirage: Beats 50%
- Summer-long cooling efficiencySEER2Kerr: Beats 64%Mirage: Beats 56%
- Hot-day cooling efficiencyEER2Kerr: Beats 62%Mirage: Beats 37%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Kerr
- 79%
- Mirage
- 77%
Xcel CC
- Kerr
- 90%
- Mirage
- 65%
CEE Advanced
- Kerr
- 3%
- Mirage
- 0%
ENERGY STAR CC
- Kerr
- 90%
- Mirage
- 38%
All-around best, ductless up to 1.5 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Kerr
- 1A-KHP06SA-1with ductless indoor unit B-KHP06SA-1Kerr0.5 tons · 6,000 Btu/h · DuctlessCold-climate pick, score 96.7Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 110% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.40 (COP at 5°F)
- Top 10%
- Winter efficiency
- 14.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 25.5 (SEER2)
- Top 10%
- Hot-day cooling
- 18.0 (EER2)
- Top 10%
- 2A-KZP06SA-1with ductless indoor unit B-ZKP06SA-1KerrAlso listed as A-ZKP06SA-10.5 tons · 6,000 Btu/h · DuctlessCold-climate pick, score 87.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 150% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 15.6 (HSPF2)
- Top 10%
- Cooling efficiency
- 35.0 (SEER2)
- Top 10%
- Hot-day cooling
- 17.4 (EER2)
- Top 10%
- 3A-KZPO9SA-1with ductless indoor unit B-ZKPO9SA-1KerrAlso listed as A-ZKP09SA-11 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 85.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 113% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 14.6 (HSPF2)
- Top 10%
- Cooling efficiency
- 33.3 (SEER2)
- Top 10%
- Hot-day cooling
- 17.0 (EER2)
- Top 10%
Mirage
- 1OGFH181CMirage1.5 tons · 18,000 Btu/h · DuctlessCold-climate pick, score 68.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 80% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Great
- Cooling efficiency
- 24.0 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Good
- 2OMZH121Cwith ductless indoor unit OMZH121CMirageAlso listed as OMZH121C1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 59.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 24.0 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Good
- 3OMZH120Cwith ductless indoor unit OMZH120CMirageAlso listed as OMZH120C1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 58.9Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 23.0 (SEER2)
- Good
- Hot-day cooling
- 13.0 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view