Skip to content

KLIMAIRE vs Waykar: heat pump ratings compared

Against heat pumps of the same size and type, a typical KLIMAIRE model beats 55% and a typical Waykar model 34%. KLIMAIRE rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

KLIMAIRE

55%

of similar heat pumps beaten by its typical model

About average

25 models listed

Waykar

34%

of similar heat pumps beaten by its typical model

Well below average

26 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FKLIMAIRE: Beats 50%Waykar: Beats 25%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FKLIMAIRE: Beats 48%Waykar: Beats 36%
  • Winter-long heating efficiencyHSPF2KLIMAIRE: Beats 60%Waykar: Beats 51%
  • Summer-long cooling efficiencySEER2KLIMAIRE: Beats 61%Waykar: Beats 34%
  • Hot-day cooling efficiencyEER2KLIMAIRE: Beats 52%Waykar: Beats 26%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    KLIMAIRE
    76%
    Waykar
    69%
  • Xcel CC

    KLIMAIRE
    72%
    Waykar
    62%
  • CEE Advanced

    KLIMAIRE
    0%
    Waykar
    0%
  • ENERGY STAR CC

    KLIMAIRE
    0%
    Waykar
    0%

All-around best, ductless up to 1.5 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

KLIMAIRE

  1. 1KMIP218-H225-4KLIMAIRE1.5 tons · 18,000 Btu/h · DuctlessCold-climate pick, score 68.6Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    80% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    24.0 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Good
    72.2score / 100Heating 69 · Cooling 76
  2. 2KOIQ12H2-45Twith ductless indoor unit KIWQ12H2-45TKLIMAIRE1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 59.5Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    24.0 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Good
    67.7score / 100Heating 60 · Cooling 76
  3. 3KOIQ12H1-45Twith ductless indoor unit KIWQ12H1-45TKLIMAIRE1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 58.9Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    23.0 (SEER2)
    Good
    Hot-day cooling
    13.0 (EER2)
    Good
    65.0score / 100Heating 59 · Cooling 71

Waykar

  1. 1TSHWE230-09K-32-Owith ductless indoor unit TSHWE230-09K-32-IWaykarAlso listed as TSHWA230-09K-32-O1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 42.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    80% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.5 (EER2)
    Good
    46.6score / 100Heating 42 · Cooling 51
  2. 2TSHWE230-09K-Owith ductless indoor unit TSHWE230-09K-IWaykarAlso listed as TSHWA230-09K-O1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 50.4Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    74% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Below the middle
    43.9score / 100Heating 50 · Cooling 37
  3. 3TSHWE115-09K-32-Owith ductless indoor unit TSHWE115-09K-32-IWaykarAlso listed as TSHWA115-09K-32-O1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 42.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    80% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    20.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Below the middle
    39.7score / 100Heating 42 · Cooling 37

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view