Skip to content

Puremind vs THERMAL ZONE: heat pump ratings compared

Against heat pumps of the same size and type, a typical Puremind model beats 37% and a typical THERMAL ZONE model 30%. Puremind rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Puremind

37%

of similar heat pumps beaten by its typical model

Well below average

95 models listed

THERMAL ZONE

30%

of similar heat pumps beaten by its typical model

Well below average

101 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FPuremind: Beats 24%THERMAL ZONE: Beats 40%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FPuremind: Beats 40%THERMAL ZONE: Beats 26%
  • Winter-long heating efficiencyHSPF2Puremind: Beats 51%THERMAL ZONE: Beats 23%
  • Summer-long cooling efficiencySEER2Puremind: Beats 44%THERMAL ZONE: Beats 24%
  • Hot-day cooling efficiencyEER2Puremind: Beats 28%THERMAL ZONE: Beats 31%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Puremind
    47%
    THERMAL ZONE
    8%
  • Xcel CC

    Puremind
    53%
    THERMAL ZONE
    8%
  • CEE Advanced

    Puremind
    0%
    THERMAL ZONE
    0%
  • ENERGY STAR CC

    Puremind
    0%
    THERMAL ZONE
    8%

All-around best, ducted 3.5–4.5 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Puremind

  1. 1PTF48B1-EBH4Uwith ducted air handler PTF48B1-EBH4UPuremindAlso listed as PTF60B1-EBH4U, ATF48B1-EBH4U, ATF60B1-EBH4U, CTF48B1-EBH4U and 1 more4.5 tons · 53,000 Btu/h · DuctedCold-climate pick, score 42.8Meets none of the standards tracked here
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.2 (HSPF2)
    Good
    Cooling efficiency
    17.0 (SEER2)
    Good
    Hot-day cooling
    8.0 (EER2)
    Below the middle
    38.0score / 100Heating 43 · Cooling 33
  2. 2PTF48B1-BBH4Uwith ducted air handler PTF48B1-BBH4UPuremindAlso listed as ATF48B1-BBH4U, CTF48B1-BBH4U4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 44.1Meets none of the standards tracked here
    Heat kept at 5°F
    75% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    9.0 (EER2)
    Below the middle
    34.5score / 100Heating 44 · Cooling 25
  3. 3PTF60B1-BBH4Uwith ducted air handler PTF60B1-BBH4UPuremindAlso listed as ATF60B1-BBH4U, CTF60B1-BBH4U4.5 tons · 54,000 Btu/h · DuctedCold-climate pick, score 42.8Meets none of the standards tracked here
    Heat kept at 5°F
    74% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Good
    Cooling efficiency
    14.3 (SEER2)
    Below the middle
    Hot-day cooling
    8.0 (EER2)
    Below the middle
    27.5score / 100Heating 43 · Cooling 12

THERMAL ZONE

  1. 1TZID60H520ZCwith ducted air handler TZID48H520ZATHERMAL ZONE4 tons · 47,500 Btu/h · DuctedCold-climate pick, score 64.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    17.5 (SEER2)
    Good
    Hot-day cooling
    11.3 (EER2)
    Good
    64.4score / 100Heating 64 · Cooling 65
  2. 2TZP15AY48AJ2Nwith ducted air handler 98-888+TXV+RDS+TDR+E30B5DTHERMAL ZONE4 tons · 45,000 Btu/h · DuctedNot a cold-climate pick: keeps 53% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    53% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Great
    Winter efficiency
    7.8 (HSPF2)
    Below the middle
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    54.8score / 100Heating 53 · Cooling 57
  3. 3TZP15AY42AJ2Nwith ducted air handler 98-888+TXV+RDS+TDR+E30B5DTHERMAL ZONE3.5 tons · 39,000 Btu/h · DuctedNot a cold-climate pick: keeps 50% of its heat at 5°FMeets CEE 2025, ENERGY STAR CC
    Heat kept at 5°F
    51% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    7.8 (HSPF2)
    Below the middle
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    52.8score / 100Heating 49 · Cooling 57

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view