Skip to content

SLIMAIR vs TGM: heat pump ratings compared

Against heat pumps of the same size and type, a typical SLIMAIR model beats 60% and a typical TGM model 45%. SLIMAIR rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

SLIMAIR

60%

of similar heat pumps beaten by its typical model

Well above average

48 models listed

TGM

45%

of similar heat pumps beaten by its typical model

Below average

77 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FSLIMAIR: Beats 60%TGM: Beats 48%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FSLIMAIR: Beats 59%TGM: Beats 42%
  • Winter-long heating efficiencyHSPF2SLIMAIR: Beats 73%TGM: Beats 41%
  • Summer-long cooling efficiencySEER2SLIMAIR: Beats 61%TGM: Beats 45%
  • Hot-day cooling efficiencyEER2SLIMAIR: Beats 53%TGM: Beats 42%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    SLIMAIR
    90%
    TGM
    58%
  • Xcel CC

    SLIMAIR
    77%
    TGM
    55%
  • CEE Advanced

    SLIMAIR
    2%
    TGM
    1%
  • ENERGY STAR CC

    SLIMAIR
    79%
    TGM
    21%

All-around best, ducted 3.5–4.5 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

SLIMAIR

  1. 1SHC6Z48AC2AGSLIMAIR4 tons · 45,000 Btu/h · DuctedCold-climate pick, score 77.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.6 (HSPF2)
    Top 10%
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    85.1score / 100Heating 78 · Cooling 92
  2. 2SHC6Z48AH2AGSLIMAIR4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 82.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    83.9score / 100Heating 83 · Cooling 85
  3. 3SHC6Z55AH2AGSLIMAIR4.5 tons · 53,000 Btu/h · DuctedCold-climate pick, score 81.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    87% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.7 (HSPF2)
    Top 10%
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    82.0score / 100Heating 81 · Cooling 83

TGM

  1. 1OTV18HN048Awith ducted air handler OTA18C006ATGMAlso listed as OTV18HN060A4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 72.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Great
    Winter efficiency
    9.2 (HSPF2)
    Great
    Cooling efficiency
    18.5 (SEER2)
    Great
    Hot-day cooling
    11.5 (EER2)
    Good
    72.6score / 100Heating 72 · Cooling 73
  2. 2MTVC2OCN060Awith ducted air handler MTA20C048ATGM4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 60.1Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    18.5 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    72.6score / 100Heating 60 · Cooling 85
  3. 3GMRSHT42AS5TGM3.5 tons · 42,000 Btu/h · DuctedCold-climate pick, score 55.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    86% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    69.1score / 100Heating 56 · Cooling 83

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view