Check a heat pump’s certified ratings

Type the outdoor unit’s model number from its nameplate, or the AHRI reference number from your quote. You will see its ratings, how it compares with others of its size, and the rebate standards it meets.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Partial model numbers work. AHRI numbers find the pairing listed for each model.

Ducted, 2 tons: every model, highest efficiency on a 5°f day first

One size class at a time, so the numbers compare directly.
  1. 26A5HP5024A1with indoor coil D(A,C,E)36C3J+TDR and furnace A951X060BU4SATrane (sold as Ameristar)2 tons · 21,600 Btu/h · DuctedTop 10%2.79
  2. 275TWR4030A1with indoor coil DH36T4J and furnace L8X1B060U3XSATrane2 tons · 26,200 Btu/h · DuctedTop 10%2.78
  3. 285TWX5024A1with indoor coil D(A,C,E)36C3J+TDR and furnace S9V2B080D4PSBTrane2 tons · 21,000 Btu/h · DuctedTop 10%2.78
  4. 295A6H4030A1with indoor coil DH36T4J and furnace L8X1B060U3XSATrane (sold as American Standard)2 tons · 26,200 Btu/h · DuctedTop 10%2.77
  5. 30A5HP5030A1with indoor coil D(A,C,E)36C3J+TDR and furnace A801X080CM5SDTrane (sold as Runtru)2 tons · 26,200 Btu/h · DuctedTop 10%2.77
  6. 31H5H0V24*K*AAA*with indoor coil D(A,C,E)37A3J+TDR and furnace *80CSU0401712BCarrier (sold as HEIL)2 tons · 23,000 Btu/h · DuctedTop 10%2.76
  7. 32H5H6S24*K*AAA*with indoor coil D(A,C,E)37A3J+TDR and furnace *96MSN0802120ACarrier (sold as HEIL)2 tons · 21,800 Btu/h · DuctedTop 10%2.76
  8. 33N5H5S24*K*AAA*with indoor coil D(A,C,E)37A3J+TDR and furnace *96MSN0802120ACarrier (sold as HEIL)2 tons · 21,800 Btu/h · DuctedTop 10%2.76
  9. 34RD16AY24AJVCwith ducted air handler PE(S,T)34JRheem (sold as RUUD)2 tons · 22,000 Btu/h · DuctedTop 10%2.76
  10. 35AOH-24U3R25Ewith ducted air handler AE*S+CM36B2Z+TXV+TDRHisense2 tons · 23,000 Btu/h · DuctedTop 10%2.75
  11. 36A5HP4030A1with indoor coil D(A,C,E)36C3J+TDR and furnace A801X060AM3SDTrane (sold as Ameristar)2 tons · 25,200 Btu/h · DuctedTop 10%2.75
  12. 37R5H5S24*K*AAA*with indoor coil D(A,C,E)36B3J+TDR and furnace *80MS(N,L)0902120ACarrier (sold as Tempstar)2 tons · 21,600 Btu/h · DuctedTop 10%2.74
  13. 387HP14F24P-**Awith indoor coil D(A,C,E)36D3J+TDR and furnace 80G1UH090BE16Lennox (sold as Concord)2 tons · 24,000 Btu/h · DuctedTop 10%2.74
  14. 39NS21H24MA5-**Awith indoor coil D(A,C,E)24C3Z+TXV+TDR and furnace NF96U070S3BGE Appliances (sold as GE)2 tons · 21,400 Btu/h · DuctedTop 10%2.73
  15. 40A7HP14F24P-**Awith indoor coil D(A,C,E)30B4J+TDR and furnace A80UH1E090B16Lennox (sold as Armstrong Air)2 tons · 24,000 Btu/h · DuctedTop 10%2.72
  16. 41WLP15AY30AJ2Nwith ducted air handler AE*S+DM36A3J+TDRWHIRLPOOL2 tons · 26,800 Btu/h · DuctedTop 10%2.72
  17. 42235SAN024**AA*with ducted air handler PE(S,T)34JCarrier (sold as Bryant Heating and Cooling Systems)2 tons · 21,400 Btu/h · DuctedTop 10%2.70
  18. 43246SAN024**AA*with ducted air handler PE(S,T)34JCarrier (sold as Bryant Heating and Cooling Systems)2 tons · 21,400 Btu/h · DuctedTop 10%2.70
  19. 44GH5SAN524**AA*with ducted air handler PE(S,T)34JCarrier (sold as Bryant Heating and Cooling Systems)2 tons · 21,400 Btu/h · DuctedTop 10%2.70
  20. 45A5HP4024A1with indoor coil D(A,C,E)36C3J+TDR and furnace A951X060BU4SATrane (sold as Ameristar)2 tons · 22,000 Btu/h · DuctedTop 10%2.70
  21. 46BOVA-36RTB-M20Swith ducted air handler L(E,G)M24FJBosch2 tons · 21,400 Btu/h · DuctedTop 10%2.69
  22. 4737MUHAQ24AA3+TIC2025-0016with ducted air handler L(E,G)M36DJCarrier2 tons · 23,200 Btu/h · DuctedTop 10%2.69
  23. 48HSA1424S1-**Awith indoor coil D(A,C,E)24B4J+TDR and furnace GDD80C090B4MPCentury2 tons · 21,600 Btu/h · DuctedTop 10%2.69
  24. 49NS16H24SA5-**Awith indoor coil D(A,C,E)24B4J+TDR and furnace NF80D090S4BGE Appliances (sold as GE)2 tons · 21,600 Btu/h · DuctedTop 10%2.69
  25. 50HSA1424S1-**Awith indoor coil D(A,C,E)24B4J+TDR and furnace GDD80C090B4MPLennox (sold as Comfort-Aire)2 tons · 21,600 Btu/h · DuctedTop 10%2.69

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What size is my system?

Tons and Btu

A heat pump’s size is its rated cooling output, in Btu per hour. Installers talk in tons: one ton is 12,000 Btu per hour, so a 3-ton unit is about 36,000.

Where to find yours: the nameplate sticker on the outdoor unit lists the model number. Many model numbers include the size in thousands of Btu, such as 24 (2 tons), 36 (3 tons) or 48 (4 tons). Your quote or AHRI certificate also lists it. Look up a model number

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Size classes used here

  • Up to 1.5 tonsunder 21,000 Btu/h
  • 2 tons21,000–26,999 Btu/h
  • 2.5–3 tons27,000–38,999 Btu/h
  • 3.5–4.5 tons39,000–56,999 Btu/h
  • 5 tons and up57,000 Btu/h and up

The advanced view lists every model with filters for brand, standard, size and type, sortable by any rating.

Open the advanced view