1HVAC heat pump efficiency: 87 outdoor models compared
1HVAC has 87 heat pump outdoor models certified with this refrigerant group, in 1,190 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes 1HVAC makes. 1HVAC has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 87
- AHRI certifications
- 1,190
- Efficiency index
- 54%
- Typical model vs same-size, same-type peers (109 models)
- Meet CEE 2025
- 63.2%
- 55 models
How 1HVAC compares with comparable models
- 1HVAC
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index109 models scored | 54% | Not ranked | — |
| COP at 5°F109 models scored | 44% | Not ranked | 1.90 |
| Capacity retention at 5°F109 models scored | 62% | Not ranked | 77% |
| HSPF2111 models scored | 61% | Not ranked | 9.2 |
| SEER2111 models scored | 59% | Not ranked | 18.0 |
| EER2111 models scored | 43% | Not ranked | 11.0 |
| Heating capacity at 5°F109 models scored | 61% | Not ranked | 23,400 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 63.2% | 55 |
| CEE 2026 Tier 1 (Split ASHP) | 59.8% | 52 |
| CEE Advanced Tier (Split ASHP) | 1.1% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 55.2% | 48 |
| DOE Cold Climate Heat Pump Challenge | 1.1% | 1 |
| ENERGY STAR Cold Climate | 41.4% | 36 |
Sizes and duct types offered
- 1HVAC (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 9 | 57% | 43% | 62% | 62% |
| Ducted, 2 tons | 10 | 58% | 43% | 66% | 65% |
| Ducted, 2.5–3 tons | 18 | 54% | 44% | 66% | 61% |
| Ducted, 3.5–4.5 tons | 22 | 53% | 41% | 71% | 66% |
| Non-ducted, up to 1.5 tons | 21 | 55% | 50% | 59% | 60% |
| Non-ducted, 2 tons | 6 | 51% | 52% | 59% | 48% |
| Non-ducted, 2.5–3 tons | 17 | 53% | 40% | 51% | 51% |
| Non-ducted, 3.5–4.5 tons | 8 | 47% | 36% | 46% | 52% |
Every 1HVAC model in the market
- 1HVAC models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top 1HVAC models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ACIQ-06ZPL-HP230B1HVAC · ACIQwith ductless indoor unit ACIQ-06W-HH-MC | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 7,500 | 26.5 | CEE 25CEE 26XcelES CC | 2 | 210857294 | Non-ducted, up to 1.5 tons | 89.3 |
| 2ACIQ-24ZPL-HP230B1HVAC · ACIQwith ductless indoor unit ACIQ-24FM-HH-MB | 2 tons24,000 Btu/h · Non-ducted | 102% | 2.10 | 11.0 | 25,000 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 207825525 | Non-ducted, 2 tons | 87.1 |
| 3ACIQ-18-HPB1HVAC · ACIQ serieswith ducted air handler ACIQ-18W-WM | 1.5 tons18,000 Btu/h · Ducted | 99% | 2.30 | 10.8 | 18,800 | 19.3 | CEE 25CEE 26XcelES CC | 5 | 213433229 | Ducted, up to 1.5 tons | 86.9 |
| 4ACIQ-48ZPL-HP230B1HVAC · ACIQwith ducted air handler ACIQ-48CD-HH-MB | 4 tons48,000 Btu/h · Ducted | 88% | 2.02 | 10.3 | 46,000 | 14.3 | None | 3 | 210857302 | Ducted, 3.5–4.5 tons | 86.4 |
| 5ACIQ-60ZPL-HP230B1HVAC · ACIQwith ducted air handler ACIQ-60CD-HH-MB | 4.5 tons55,000 Btu/h · Ducted | 93% | 1.97 | 9.5 | 53,000 | 15.8 | ES CC | 2 | 210857303 | Ducted, 3.5–4.5 tons | 82.0 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ACIQ-06ZPL-HP230B1HVAC · ACIQwith ductless indoor unit ACIQ-06W-HH-MC | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 26.5 | 15.8 | CEE 25CEE 26XcelES CC | 2 | 210857294 | Non-ducted, up to 1.5 tons | 92.0 | 89.3 | 94.7 | 89.3 |
| 2SC-09ZPL-HP2301HVACwith ductless indoor unit SC-09WPL-HP230 | 1 ton9,000 Btu/h · Non-ducted | 144% | 1.91 | 11.0 | 27.0 | 16.6 | CEE 25CEE 26Xcel | 1 | 208650726 | Non-ducted, up to 1.5 tons | 88.7 | 80.1 | 97.3 | 80.1 |
| 3ACIQ-09ZPL-HP230B1HVAC · ACIQwith ductless indoor unit ACIQ-09W-HH-MB | 1 ton9,000 Btu/h · Non-ducted | 94% | 1.97 | 11.5 | 28.1 | 16.2 | CEE 25CEE 26XcelES CC | 5 | 207825512 | Non-ducted, up to 1.5 tons | 87.7 | 77.4 | 97.9 | 77.4 |
| 4ACIQ-09ZPL-HP230B1HVAC · ACIQwith ducted air handler ACIQ-09CD-HH-MB | 1 ton9,000 Btu/h · Ducted | 108% | 1.90 | 12.0 | 20.2 | 13.2 | CEE 25CEE 26XcelES CC | 5 | 207825519 | Ducted, up to 1.5 tons | 85.2 | 74.9 | 95.5 | 74.9 |
| 5ACIQ-24ZPL-HP230B1HVAC · ACIQwith ductless indoor unit ACIQ-24W-HH-MC | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 21.5 | 13.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 210857298 | Non-ducted, 2 tons | 84.3 | 84.5 | 84.1 | 87.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ACIQ-24ZPL-HP230B | 2.21 | Non-ducted, 2 tons | 91% | 210857298 |
| Capacity retention at 5°F | SC-09ZPL-HP230 | 144% | Non-ducted, up to 1.5 tons | 99% | 208650726 |
| HSPF2 | ACIQ-48ZPL-HP230B | 10.3 | Ducted, 3.5–4.5 tons | 99% | 210857302 |
| SEER2 | ES-27Z-M3B | 24.6 | Non-ducted, 2.5–3 tons | 99% | 210857368 |
| EER2 | SC-09ZPL-HP230 | 16.6 | Non-ducted, up to 1.5 tons | 99% | 208650726 |
| Heating capacity at 5°F | ACIQ-60ZPL-HP230B | 56,500 Btu/h | Non-ducted, 3.5–4.5 tons | 99% | 210857306 |
1HVAC size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class)ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM8 of 9 models qualify · AHRI 213433229 | 85.2(50 is the typical model of its size class)ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB9 of 9 models have all five ratings · AHRI 207825519 |
| Ducted, 2 tons | 80.7(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB9 of 9 models qualify · AHRI 207825522 | 80.8(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB10 of 10 models have all five ratings · AHRI 207825522 |
| Ducted, 2.5–3 tons | 79.9(50 is the typical model of its size class)ACIQ-36ZPL-HP230Bwith ducted air handler ACIQ-36CD-HH-MB14 of 19 models qualify · AHRI 210857301 | 75.4(50 is the typical model of its size class)HVH837GKA2*with indoor coil EN(A,D,W)4X60L24**+WALLCON and furnace *95CSU0802120A18 of 18 models have all five ratings · AHRI 210470878 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class)ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MB14 of 22 models qualify · AHRI 210857302 | 82.0(50 is the typical model of its size class)ACIQ-48Z-HH-M5B21 of 21 models have all five ratings · AHRI 207825574 |
| Ducted, 5 tons and up | No models in this size class | 41.7(50 is the typical model of its size class)ACIQ-60-EHPBwith ducted air handler ACIQ-60AHB1 of 1 models have all five ratings · AHRI 213433223 |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC11 of 21 models qualify · AHRI 210857294 | 92.0(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC21 of 21 models have all five ratings · AHRI 210857294 |
| Non-ducted, 2 tons | 87.1(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24FM-HH-MB3 of 6 models qualify · AHRI 207825525 | 84.3(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24W-HH-MC6 of 6 models have all five ratings · AHRI 210857298 |
| Non-ducted, 2.5–3 tons | 79.3(50 is the typical model of its size class)ACIQ-36Z-HH-M4B9 of 17 models qualify · AHRI 207825570 | 82.8(50 is the typical model of its size class)ACIQ-36Z-HH-M4B15 of 17 models have all five ratings · AHRI 207825570 |
| Non-ducted, 3.5–4.5 tons | 76.8(50 is the typical model of its size class)ACIQ-60ZPL-HP230Bwith ductless indoor unit ACIQ-60FM-HH-MB5 of 8 models qualify · AHRI 210857306 | 77.9(50 is the typical model of its size class)ACIQ-48Z-HH-M5B8 of 8 models have all five ratings · AHRI 207825573 |
Newest 1HVAC certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| SC-27Z-HH-M4B1HVAC · Extreme Heat | 2 tons23,200 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 90% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 215742357 |
| ACIQ-30-HPB1HVAC · ACIQ Serieswith ducted air handler ACIQ-30-AHB | 2.5 tons30,000 Btu/h · Ducted | 1.80 | 73% | 8.9 | 16.2 | CEE 25CEE 26XcelES CC | 6 | 215570366 |
| EZ-36-HP1HVAC · EZ Serieswith ducted air handler EZ-36-AH | 3 tons36,000 Btu/h · Ducted | 1.86 | 99% | 9.5 | 16.0 | CEE 25CEE 26XcelES CC | 1 | 215463873 |
| ACIQ-PHH1760000K000V1HVAC · Extreme Heat Inverter Rooftop | 4.5 tons56,000 Btu/h · Ducted | 1.80 | 79% | 8.3 | 17.0 | XcelES CC | 1 | 215387221 |
| ACIQ-PHH1748000K000V1HVAC · Extreme Heat Inverter Rooftop | 4 tons47,000 Btu/h · Ducted | 1.80 | 98% | 8.5 | 17.8 | CEE 25CEE 26XcelES CC | 1 | 215387220 |
Compare 1HVAC
1HVAC includes these brand names as listed in AHRI: 1HVAC. Standards are checked against published thresholds; program rules beyond ratings are not checked.