- Insights
- Manufacturers
- AIR TECH
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AIR TECH heat pump efficiency: 5 outdoor models compared
AIR TECH has 5 heat pump outdoor models certified with this refrigerant group, in 11 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes AIR TECH makes. AIR TECH has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 5
- AHRI certifications
- 11
- Efficiency index
- 60%
- Typical model vs same-size, same-type peers (8 models)
- Meet CEE 2025
- 100%
- 5 models
How AIR TECH compares with comparable models
- AIR TECH
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index8 models scored | 60% | Not ranked | — |
| COP at 5°F8 models scored | 58% | Not ranked | 2.10 |
| Capacity retention at 5°F8 models scored | 59% | Not ranked | 70% |
| HSPF28 models scored | 37% | Not ranked | 9.0 |
| SEER28 models scored | 84% | Not ranked | 23.0 |
| EER28 models scored | 53% | Not ranked | 12.5 |
| Heating capacity at 5°F8 models scored | 60% | Not ranked | 25,200 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 5 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 5 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100% | 5 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- AIR TECH (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, 2.5–3 tons | 1 | 67% | 79% | 52% | 81% |
| Ducted, 3.5–4.5 tons | 1 | 56% | 41% | 53% | 81% |
| Ducted, 5 tons and up | 1 | 54% | 26% | 49% | 88% |
| Non-ducted, up to 1.5 tons | 2 | 53% | 38% | 29% | 80% |
| Non-ducted, 2.5–3 tons | 1 | 77% | 98% | 48% | 84% |
| Non-ducted, 3.5–4.5 tons | 1 | 69% | 95% | 33% | 86% |
| Non-ducted, 5 tons and up | 1 | 50% | 50% | 8% | 89% |
Every AIR TECH model in the market
- AIR TECH models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top AIR TECH models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ATVO36NGUG2AIR TECH | 3 tons36,000 Btu/h · Non-ducted | 70% | 2.40 | 9.0 | 25,200 | 23.0 | CEE 25CEE 26Xcel | 3 | 214056553 | Non-ducted, 2.5–3 tons | 65.5 |
| 2ATVO36NGUG2AIR TECH | 3 tons36,000 Btu/h · Ducted | 70% | 2.10 | 8.3 | 25,200 | 18.5 | CEE 25CEE 26Xcel | 3 | 214056552 | Ducted, 2.5–3 tons | 62.5 |
| 3ATVO48NGUG2AIR TECH | 4 tons48,000 Btu/h · Non-ducted | 70% | 2.20 | 9.2 | 33,600 | 22.0 | CEE 25CEE 26Xcel | 3 | 214056550 | Non-ducted, 3.5–4.5 tons | 57.5 |
| 4ATVO60NGUG2AIR TECH | 5 tons60,000 Btu/h · Ducted | 70% | 1.80 | 7.8 | 42,000 | 17.0 | None | 3 | 214056547 | Ducted, 5 tons and up | 55.0 |
| 5ATVO48NGUG2AIR TECH | 4 tons48,000 Btu/h · Ducted | 70% | 1.90 | 8.1 | 33,600 | 17.1 | Xcel | 3 | 214056549 | Ducted, 3.5–4.5 tons | 52.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ATVO36NGUG2AIR TECH | 3 tons36,000 Btu/h · Non-ducted | 70% | 2.40 | 9.0 | 23.0 | 13.0 | CEE 25CEE 26Xcel | 3 | 214056553 | Non-ducted, 2.5–3 tons | 77.0 | 65.5 | 88.5 | 65.5 |
| 2ATVO48NGUG2AIR TECH | 4 tons48,000 Btu/h · Non-ducted | 70% | 2.20 | 9.2 | 22.0 | 11.5 | CEE 25CEE 26Xcel | 3 | 214056550 | Non-ducted, 3.5–4.5 tons | 69.0 | 57.5 | 80.4 | 57.5 |
| 3ATVO36NGUG2AIR TECH | 3 tons36,000 Btu/h · Ducted | 70% | 2.10 | 8.3 | 18.5 | 11.5 | CEE 25CEE 26Xcel | 3 | 214056552 | Ducted, 2.5–3 tons | 67.0 | 62.5 | 71.5 | 62.5 |
| 4ATSO12NAMG2AIR TECHwith ductless indoor unit ATSW12NAMG2 | 1 ton12,000 Btu/h · Non-ducted | 75% | 1.85 | 9.0 | 24.0 | 12.5 | CEE 25CEE 26Xcel | 1 | 214010063 | Non-ducted, up to 1.5 tons | 56.9 | 46.5 | 67.2 | 46.5 |
| 5ATVO48NGUG2AIR TECH | 4 tons48,000 Btu/h · Ducted | 70% | 1.90 | 8.1 | 17.1 | 10.5 | Xcel | 3 | 214056549 | Ducted, 3.5–4.5 tons | 56.0 | 52.8 | 59.2 | 52.8 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ATVO36NGUG2 | 2.40 | Non-ducted, 2.5–3 tons | 98% | 214056553 |
| Capacity retention at 5°F | ATVO60NGUG2 | 70% | Ducted, 5 tons and up | 88% | 214056547 |
| HSPF2 | ATVO48NGUG2 | 8.1 | Ducted, 3.5–4.5 tons | 49% | 214056549 |
| SEER2 | ATVO60NGUG2 | 17.0 | Ducted, 5 tons and up | 86% | 214056547 |
| EER2 | ATVO36NGUG2 | 13.0 | Non-ducted, 2.5–3 tons | 93% | 214056553 |
| Heating capacity at 5°F | ATVO60NGUG2 | 42,000 Btu/h | Ducted, 5 tons and up | 93% | 214056547 |
AIR TECH size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, 2.5–3 tons | 62.5(50 is the typical model of its size class)ATVO36NGUG21 of 1 models qualify · AHRI 214056552 | 67.0(50 is the typical model of its size class)ATVO36NGUG21 of 1 models have all five ratings · AHRI 214056552 |
| Ducted, 3.5–4.5 tons | 52.8(50 is the typical model of its size class)ATVO48NGUG21 of 1 models qualify · AHRI 214056549 | 56.0(50 is the typical model of its size class)ATVO48NGUG21 of 1 models have all five ratings · AHRI 214056549 |
| Ducted, 5 tons and up | 55.0(50 is the typical model of its size class)ATVO60NGUG21 of 1 models qualify · AHRI 214056547 | 53.9(50 is the typical model of its size class)ATVO60NGUG21 of 1 models have all five ratings · AHRI 214056547 |
| Non-ducted, up to 1.5 tons | 46.5(50 is the typical model of its size class)ATSO12NAMG2with ductless indoor unit ATSW12NAMG22 of 2 models qualify · AHRI 214010063 | 56.9(50 is the typical model of its size class)ATSO12NAMG2with ductless indoor unit ATSW12NAMG22 of 2 models have all five ratings · AHRI 214010063 |
| Non-ducted, 2.5–3 tons | 65.5(50 is the typical model of its size class)ATVO36NGUG21 of 1 models qualify · AHRI 214056553 | 77.0(50 is the typical model of its size class)ATVO36NGUG21 of 1 models have all five ratings · AHRI 214056553 |
| Non-ducted, 3.5–4.5 tons | 57.5(50 is the typical model of its size class)ATVO48NGUG21 of 1 models qualify · AHRI 214056550 | 69.0(50 is the typical model of its size class)ATVO48NGUG21 of 1 models have all five ratings · AHRI 214056550 |
| Non-ducted, 5 tons and up | 36.0(50 is the typical model of its size class)ATVO60NGUG21 of 1 models qualify · AHRI 214056546 | 49.5(50 is the typical model of its size class)ATVO60NGUG21 of 1 models have all five ratings · AHRI 214056546 |
Newest AIR TECH certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| ATVO36NGUG2AIR TECH | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.30 | 70% | 8.9 | 20.8 | CEE 25CEE 26Xcel | 3 | 214056554 |
| ATVO48NGUG2AIR TECH | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 70% | 8.9 | 19.6 | CEE 25CEE 26Xcel | 3 | 214056551 |
| ATVO60NGUG2AIR TECH | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 8.8 | 19.0 | CEE 25CEE 26Xcel | 3 | 214056548 |
| ATSO18NAMG2AIR TECHwith ductless indoor unit ATSW18NAMG2 | 1.5 tons18,000 Btu/h · Non-ducted | 1.85 | 72% | 8.5 | 23.0 | CEE 25CEE 26Xcel | 1 | 214010066 |
| ATSO12NAMG2AIR TECHwith ductless indoor unit ATSW12NAMG2 | 1 ton12,000 Btu/h · Non-ducted | 1.85 | 75% | 9.0 | 24.0 | CEE 25CEE 26Xcel | 1 | 214010063 |
Compare AIR TECH
AIR TECH includes these brand names as listed in AHRI: AIR TECH. Standards are checked against published thresholds; program rules beyond ratings are not checked.