Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ARCTIC KING heat pump efficiency: 5 outdoor models compared
ARCTIC KING has 5 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes ARCTIC KING makes. ARCTIC KING has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 5
- AHRI certifications
- 5
- Efficiency index
- 35%
- Typical model vs same-size, same-type peers (2 models)
- Meet CEE 2025
- 20%
- 1 model
How ARCTIC KING compares with comparable models
- ARCTIC KING
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index2 models scored | 35% | Not ranked | — |
| COP at 5°F2 models scored | 40% | Not ranked | 1.85 |
| Capacity retention at 5°F2 models scored | 28% | Not ranked | 64% |
| HSPF25 models scored | 29% | Not ranked | 9.0 |
| SEER25 models scored | 23% | Not ranked | 17.0 |
| EER25 models scored | 27% | Not ranked | 9.0 |
| Heating capacity at 5°F2 models scored | 29% | Not ranked | 15,900 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 20% | 1 |
| CEE 2026 Tier 1 (Split ASHP) | 20% | 1 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- ARCTIC KING (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, 2 tons | 2 | 35% | 40% | 15% | 37% |
| Non-ducted, 2.5–3 tons | 1 | — | — | 58% | 17% |
| Non-ducted, 3.5–4.5 tons | 2 | — | — | 27% | 12% |
Every ARCTIC KING model in the market
- ARCTIC KING models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top ARCTIC KING models
Cold-climate picks
No ARCTIC KING model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MOD33-24HFN1-MT0WARCTIC KING · MOD Serieswith ductless indoor unit MSAG11D-23HRFN1-MU0W | 2 tons24,000 Btu/h · Non-ducted | 64% | 1.90 | 8.5 | 21.0 | 13.0 | CEE 25CEE 26 | 1 | 207821945 | Non-ducted, 2 tons | 56.4 | 35.1 | 77.8 | Not a pick |
| 2MOX430-24HFN1-MQ0WARCTIC KINGwith ductless indoor unit MSAFD-24HRDN1-MQ0W | 2 tons24,000 Btu/h · Non-ducted | 63% | 1.80 | 8.0 | 16.7 | 8.9 | None | 1 | 207821946 | Non-ducted, 2 tons | 12.7 | 20.2 | 5.2 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | MOD33-24HFN1-MT0W | 1.90 | Non-ducted, 2 tons | 55% | 207821945 |
| Capacity retention at 5°F | MOD33-24HFN1-MT0W | 64% | Non-ducted, 2 tons | 29% | 207821945 |
| HSPF2 | MOD30U-36HFN1-M | 9.3 | Non-ducted, 2.5–3 tons | 57% | 205823044 |
| SEER2 | MOD33-24HFN1-MT0W | 21.0 | Non-ducted, 2 tons | 66% | 207821945 |
| EER2 | MOD33-24HFN1-MT0W | 13.0 | Non-ducted, 2 tons | 84% | 207821945 |
| Heating capacity at 5°F | MOD33-24HFN1-MT0W | 16,700 Btu/h | Non-ducted, 2 tons | 35% | 207821945 |
ARCTIC KING size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, 2 tons | None on this board (0 of 2 models qualify) | 56.4(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ductless indoor unit MSAG11D-23HRFN1-MU0W2 of 2 models have all five ratings · AHRI 207821945 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 1 models have all five ratings) |
| Non-ducted, 3.5–4.5 tons | None on this board (0 of 2 models qualify) | None on this board (0 of 2 models have all five ratings) |
Newest ARCTIC KING certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| MOX430-24HFN1-MQ0WARCTIC KINGwith ductless indoor unit MSAFD-24HRDN1-MQ0W | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 63% | 8.0 | 16.7 | None | 1 | 207821946 |
| MOD33-24HFN1-MT0WARCTIC KING · MOD Serieswith ductless indoor unit MSAG11D-23HRFN1-MU0W | 2 tons24,000 Btu/h · Non-ducted | 1.90 | 64% | 8.5 | 21.0 | CEE 25CEE 26 | 1 | 207821945 |
| MOD30U-36HFN1-MARCTIC KINGwith ductless indoor unit MCD-36HRFN1-M(C) | 3 tons36,000 Btu/h · Non-ducted | — | — | 9.3 | 17.5 | None | 1 | 205823044 |
| MOE30U-48HFN1-MARCTIC KINGwith ductless indoor unit MCD-48HRFN1-M(D) | 4 tons48,000 Btu/h · Non-ducted | — | — | 9.0 | 16.8 | None | 1 | 205823042 |
| MOE30U-48HFN1-M-[X]ARCTIC KINGwith ductless indoor unit MUE-48HRFN1-M(C) | 4 tons48,000 Btu/h · Non-ducted | — | — | 9.2 | 17.0 | None | 1 | 205823041 |
Compare ARCTIC KING