- Insights
- Manufacturers
- Bladex
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Bladex heat pump efficiency: 56 outdoor models compared
Bladex has 56 heat pump outdoor models certified with this refrigerant group, in 141 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Bladex makes. Bladex has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 56
- AHRI certifications
- 141
- Efficiency index
- 56%
- Typical model vs same-size, same-type peers (75 models)
- Meet CEE 2025
- 66.1%
- 37 models
How Bladex compares with comparable models
- Bladex
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index75 models scored | 56% | Not ranked | — |
| COP at 5°F75 models scored | 45% | Not ranked | 1.90 |
| Capacity retention at 5°F75 models scored | 61% | Not ranked | 79% |
| HSPF275 models scored | 68% | Not ranked | 9.5 |
| SEER275 models scored | 60% | Not ranked | 20.0 |
| EER275 models scored | 49% | Not ranked | 10.7 |
| Heating capacity at 5°F75 models scored | 61% | Not ranked | 22,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 66.1% | 37 |
| CEE 2026 Tier 1 (Split ASHP) | 62.5% | 35 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 57.1% | 32 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Bladex (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 5 | 51% | 41% | 52% | 53% |
| Ducted, 2 tons | 2 | 50% | 62% | 84% | 47% |
| Ducted, 2.5–3 tons | 17 | 62% | 41% | 82% | 67% |
| Ducted, 3.5–4.5 tons | 12 | 57% | 37% | 79% | 71% |
| Non-ducted, up to 1.5 tons | 17 | 47% | 53% | 54% | 46% |
| Non-ducted, 2 tons | 3 | 41% | 53% | 47% | 38% |
| Non-ducted, 2.5–3 tons | 13 | 67% | 51% | 71% | 68% |
| Non-ducted, 3.5–4.5 tons | 6 | 56% | 34% | 58% | 65% |
Every Bladex model in the market
- Bladex models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top Bladex models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1B40X-36SPHP1S*Bladex | 3 tons36,000 Btu/h · Non-ducted | 103% | 2.00 | 10.9 | 37,000 | 22.4 | CEE 25CEE 26Xcel | 3 | 214232423 | Non-ducted, 2.5–3 tons | 91.1 |
| 2BS25-06HFN1-ODUBladexwith ductless indoor unit BWM-EPB-06HWIU | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 7,500 | 26.5 | CEE 25CEE 26Xcel | 2 | 214312550 | Non-ducted, up to 1.5 tons | 89.3 |
| 3B40XS-36SPHP1Bladex | 3 tons36,000 Btu/h · Non-ducted | 100% | 1.95 | 10.9 | 36,000 | 21.0 | CEE 25CEE 26Xcel | 3 | 213307893 | Non-ducted, 2.5–3 tons | 87.0 |
| 4BS25-24HFN1-ODUBladexwith ductless indoor unit BWM-EPB-24HWIU | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 25,000 | 21.5 | CEE 25CEE 26Xcel | 2 | 214312554 | Non-ducted, 2 tons | 84.5 |
| 5B30K-27SPHP1*Bladex | 2.5 tons27,000 Btu/h · Non-ducted | 103% | 1.92 | 10.0 | 27,800 | 21.8 | CEE 25CEE 26Xcel | 3 | 214232414 | Non-ducted, 2.5–3 tons | 83.1 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1BS25-06HFN1-ODUBladexwith ductless indoor unit BWM-EPB-06HWIU | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 26.5 | 15.8 | CEE 25CEE 26Xcel | 2 | 214312550 | Non-ducted, up to 1.5 tons | 92.0 | 89.3 | 94.7 | 89.3 |
| 2BS25-09HFN1-ODUBladexwith ductless indoor unit BWM-EPB-09HWIU | 1 ton9,000 Btu/h · Non-ducted | 88% | 1.97 | 11.5 | 28.1 | 16.2 | CEE 25CEE 26Xcel | 2 | 214312551 | Non-ducted, up to 1.5 tons | 87.0 | 76.2 | 97.9 | 76.2 |
| 3B40X-36SPHP1S*Bladex | 3 tons36,000 Btu/h · Non-ducted | 103% | 2.00 | 10.9 | 22.4 | 12.5 | CEE 25CEE 26Xcel | 3 | 214232423 | Non-ducted, 2.5–3 tons | 86.4 | 91.1 | 81.8 | 91.1 |
| 4BS25-24HFN1-ODUBladexwith ductless indoor unit BWM-EPB-24HWIU | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 21.5 | 13.0 | CEE 25CEE 26Xcel | 2 | 214312554 | Non-ducted, 2 tons | 84.3 | 84.5 | 84.1 | 84.5 |
| 5B40XS-36SPHP1BladexAlso listed as B40X-36SPHP1S | 3 tons36,000 Btu/h · Ducted | 100% | 1.90 | 10.0 | 19.4 | 12.0 | CEE 25CEE 26Xcel | 3 | 213307894 | Ducted, 2.5–3 tons | 83.7 | 79.9 | 87.5 | 79.9 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | BS25-24HFN1-ODU | 2.21 | Non-ducted, 2 tons | 91% | 214312554 |
| Capacity retention at 5°F | B30K-27SPHP1* | 103% | Non-ducted, 2.5–3 tons | 97% | 214232414 |
| HSPF2 | BS25-06HFN1-ODU | 13.6 | Non-ducted, up to 1.5 tons | 98% | 214312550 |
| SEER2 | B50G-48SPHP1Also listed as B50G-48SPHP1 | 20.9 | Ducted, 3.5–4.5 tons | 99% | 212920657 |
| EER2 | BS25-09HFN1-ODU | 16.2 | Non-ducted, up to 1.5 tons | 98% | 214312551 |
| Heating capacity at 5°F | BCUC30-55ODU2024GA-X | 53,000 Btu/h | Ducted, 3.5–4.5 tons | 98% | 214377796 |
Bladex size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 63.7(50 is the typical model of its size class)BX30U-18HPHYHAwith ducted air handler BLC-24HWAC14 of 5 models qualify · AHRI 212367432 | 63.4(50 is the typical model of its size class)BX30U-18HPHYHAwith ducted air handler BLA-18HWAHU15 of 5 models have all five ratings · AHRI 212367437 |
| Ducted, 2 tons | 67.3(50 is the typical model of its size class)BX24-HP15ECOwith ducted air handler BLC-24HWAC12 of 2 models qualify · AHRI 212528004 | 65.8(50 is the typical model of its size class)BX30-24HPHYHAwith ducted air handler BLA-24HWAHU12 of 2 models have all five ratings · AHRI 212367438 |
| Ducted, 2.5–3 tons | 80.4(50 is the typical model of its size class)B30K-27SPHP1Also listed as B30K-27SPHP113 of 17 models qualify · AHRI 212920652 | 83.7(50 is the typical model of its size class)B40XS-36SPHP1Also listed as B40X-36SPHP1S17 of 17 models have all five ratings · AHRI 213307894 |
| Ducted, 3.5–4.5 tons | 82.0(50 is the typical model of its size class)BCUC30-55ODU2024GA-Xwith ducted air handler BDI-60HWFN17 of 12 models qualify · AHRI 214377796 | 82.0(50 is the typical model of its size class)B50G-48SPHP1Also listed as B50G-48SPHP112 of 12 models have all five ratings · AHRI 212920657 |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class)BS25-06HFN1-ODUwith ductless indoor unit BWM-EPB-06HWIU8 of 17 models qualify · AHRI 214312550 | 92.0(50 is the typical model of its size class)BS25-06HFN1-ODUwith ductless indoor unit BWM-EPB-06HWIU17 of 17 models have all five ratings · AHRI 214312550 |
| Non-ducted, 2 tons | 84.5(50 is the typical model of its size class)BS25-24HFN1-ODUwith ductless indoor unit BWM-EPB-24HWIU1 of 3 models qualify · AHRI 214312554 | 84.3(50 is the typical model of its size class)BS25-24HFN1-ODUwith ductless indoor unit BWM-EPB-24HWIU3 of 3 models have all five ratings · AHRI 214312554 |
| Non-ducted, 2.5–3 tons | 91.1(50 is the typical model of its size class)B40X-36SPHP1S*10 of 13 models qualify · AHRI 214232423 | 86.4(50 is the typical model of its size class)B40X-36SPHP1S*13 of 13 models have all five ratings · AHRI 214232423 |
| Non-ducted, 3.5–4.5 tons | 80.5(50 is the typical model of its size class)B50G-48SPHP14 of 6 models qualify · AHRI 212920656 | 78.8(50 is the typical model of its size class)B50G-48SPHP1*6 of 6 models have all five ratings · AHRI 214232426 |
Newest Bladex certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| BX31U-42HPHYHABladexwith ducted air handler BLCB-36B18AC-UNC | 3 tons35,000 Btu/h · Ducted | 1.85 | 83% | 8.6 | 15.5 | CEE 25CEE 26Xcel | 5 | 214489074 |
| BS17-24HFN1-ODUBladexwith ductless indoor unit BWM17FD-24HWIU | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 63% | 8.0 | 16.7 | None | 1 | 214489069 |
| BS17-18HFN1-ODUBladexwith ductless indoor unit BWM17FC-18HWIU | 1.5 tons17,000 Btu/h · Non-ducted | 1.84 | 56% | 8.7 | 18.3 | None | 1 | 214489068 |
| BS17-12HFN1-ODUBladexwith ductless indoor unit BWM17FB-12HWIU | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 59% | 8.8 | 17.6 | None | 1 | 214489067 |
| BS17-09HFN1-ODUBladexwith ductless indoor unit BWM17FB-09HWIU | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 59% | 8.8 | 17.6 | None | 1 | 214489066 |
Compare Bladex
Bladex includes these brand names as listed in AHRI: Bladex. Standards are checked against published thresholds; program rules beyond ratings are not checked.