- Insights
- Manufacturers
- Connect M
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Connect M heat pump efficiency: 5 outdoor models compared
Connect M has 5 heat pump outdoor models certified with this refrigerant group, in 9 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Connect M makes. Connect M has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 5
- AHRI certifications
- 9
- Efficiency index
- 55%
- Typical model vs same-size, same-type peers (5 models)
- Meet CEE 2025
- 60%
- 3 models
How Connect M compares with comparable models
- Connect M
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index5 models scored | 55% | Not ranked | — |
| COP at 5°F5 models scored | 53% | Not ranked | 1.91 |
| Capacity retention at 5°F5 models scored | 76% | Not ranked | 82% |
| HSPF25 models scored | 83% | Not ranked | 9.5 |
| SEER25 models scored | 52% | Not ranked | 15.6 |
| EER25 models scored | 28% | Not ranked | 10.0 |
| Heating capacity at 5°F5 models scored | 83% | Not ranked | 32,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 60% | 3 |
| CEE 2026 Tier 1 (Split ASHP) | 60% | 3 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 60% | 3 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 100% | 5 |
Sizes and duct types offered
- Connect M (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 52% | 76% | 58% | 37% |
| Ducted, 2 tons | 1 | 66% | 33% | 87% | 72% |
| Ducted, 2.5–3 tons | 1 | 53% | 68% | 93% | 36% |
| Ducted, 3.5–4.5 tons | 2 | 53% | 45% | 88% | 58% |
Every Connect M model in the market
- Connect M models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top Connect M models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CNTM16DHP36AAConnect M · CNTM Serieswith ducted air handler CNTMDCC36AA | 3 tons35,000 Btu/h · Ducted | 82% | 2.00 | 10.0 | 32,000 | 15.2 | CEE 25CEE 26XcelES CC | 2 | 215748028 | Ducted, 2.5–3 tons | 78.6 |
| 2CNTM16DHP48AAConnect M · CNTM Serieswith ducted air handler CNTM16DAH48AA | 4 tons47,000 Btu/h · Ducted | 92% | 1.90 | 9.4 | 46,000 | 15.6 | ES CC | 2 | 215748025 | Ducted, 3.5–4.5 tons | 73.8 |
| 3CNTM16DHP60AAConnect M · CNTM Serieswith ducted air handler CNTM16DAH60AA | 4.5 tons55,000 Btu/h · Ducted | 82% | 1.91 | 9.4 | 48,500 | 15.3 | ES CC | 2 | 215748026 | Ducted, 3.5–4.5 tons | 71.3 |
| 4CNTM16DHP24AAConnect M · CNTM Serieswith ducted air handler CNTM16DAH24AA | 2 tons24,000 Btu/h · Ducted | 94% | 1.91 | 10.0 | 22,600 | 17.4 | CEE 25CEE 26XcelES CC | 1 | 215748023 | Ducted, 2 tons | 66.5 |
| 5CNTM16DHP18AAConnect M · CNTM Serieswith ducted air handler CNTMDCC24AA | 1.5 tons18,000 Btu/h · Ducted | 79% | 2.20 | 9.5 | 15,000 | 16.1 | CEE 25CEE 26XcelES CC | 2 | 215748027 | Ducted, up to 1.5 tons | 63.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CNTM16DHP24AAConnect M · CNTM Serieswith ducted air handler CNTM16DAH24AA | 2 tons24,000 Btu/h · Ducted | 94% | 1.91 | 10.0 | 17.4 | 11.7 | CEE 25CEE 26XcelES CC | 1 | 215748023 | Ducted, 2 tons | 65.8 | 66.5 | 65.1 | 66.5 |
| 2CNTM16DHP18AAConnect M · CNTM Serieswith ducted air handler CNTM16DAH18AA | 1.5 tons18,000 Btu/h · Ducted | 87% | 2.04 | 9.3 | 18.0 | 12.4 | CEE 25CEE 26XcelES CC | 2 | 215748022 | Ducted, up to 1.5 tons | 63.4 | 60.4 | 66.3 | 63.7 |
| 3CNTM16DHP36AAConnect M · CNTM Serieswith ducted air handler CNTM16DAH36AA | 3 tons36,000 Btu/h · Ducted | 86% | 1.97 | 9.5 | 16.0 | 10.0 | CEE 25CEE 26XcelES CC | 2 | 215748024 | Ducted, 2.5–3 tons | 56.1 | 74.7 | 37.6 | 78.6 |
| 4CNTM16DHP60AAConnect M · CNTM Serieswith ducted air handler CNTM16DAH60AA | 4.5 tons55,000 Btu/h · Ducted | 82% | 1.91 | 9.4 | 15.3 | 8.8 | ES CC | 2 | 215748026 | Ducted, 3.5–4.5 tons | 53.3 | 71.3 | 35.3 | 71.3 |
| 5CNTM16DHP48AAConnect M · CNTM Serieswith ducted air handler CNTM16DAH48AA | 4 tons47,000 Btu/h · Ducted | 92% | 1.90 | 9.4 | 15.6 | 8.2 | ES CC | 2 | 215748025 | Ducted, 3.5–4.5 tons | 53.2 | 73.8 | 32.6 | 73.8 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CNTM16DHP18AA | 2.20 | Ducted, up to 1.5 tons | 76% | 215748027 |
| Capacity retention at 5°F | CNTM16DHP48AA | 92% | Ducted, 3.5–4.5 tons | 92% | 215748025 |
| HSPF2 | CNTM16DHP36AA | 10.0 | Ducted, 2.5–3 tons | 93% | 215748028 |
| SEER2 | CNTM16DHP24AA | 17.4 | Ducted, 2 tons | 67% | 215748023 |
| EER2 | CNTM16DHP18AA | 12.4 | Ducted, up to 1.5 tons | 72% | 215748022 |
| Heating capacity at 5°F | CNTM16DHP60AA | 48,500 Btu/h | Ducted, 3.5–4.5 tons | 95% | 215748026 |
Connect M size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 63.7(50 is the typical model of its size class)CNTM16DHP18AAwith ducted air handler CNTMDCC24AA1 of 1 models qualify · AHRI 215748027 | 63.4(50 is the typical model of its size class)CNTM16DHP18AAwith ducted air handler CNTM16DAH18AA1 of 1 models have all five ratings · AHRI 215748022 |
| Ducted, 2 tons | 66.5(50 is the typical model of its size class)CNTM16DHP24AAwith ducted air handler CNTM16DAH24AA1 of 1 models qualify · AHRI 215748023 | 65.8(50 is the typical model of its size class)CNTM16DHP24AAwith ducted air handler CNTM16DAH24AA1 of 1 models have all five ratings · AHRI 215748023 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class)CNTM16DHP36AAwith ducted air handler CNTMDCC36AA1 of 1 models qualify · AHRI 215748028 | 56.1(50 is the typical model of its size class)CNTM16DHP36AAwith ducted air handler CNTM16DAH36AA1 of 1 models have all five ratings · AHRI 215748024 |
| Ducted, 3.5–4.5 tons | 73.8(50 is the typical model of its size class)CNTM16DHP48AAwith ducted air handler CNTM16DAH48AA2 of 2 models qualify · AHRI 215748025 | 53.3(50 is the typical model of its size class)CNTM16DHP60AAwith ducted air handler CNTM16DAH60AA2 of 2 models have all five ratings · AHRI 215748026 |
Newest Connect M certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CNTM16DHP60AAConnect M · CNTM Serieswith ducted air handler CNTMDCC60AA | 4.5 tons53,000 Btu/h · Ducted | 1.80 | 85% | 8.6 | 14.5 | ES CC | 2 | 215748030 |
| CNTM16DHP48AAConnect M · CNTM Serieswith ducted air handler CNTMDCC48AA | 4 tons46,000 Btu/h · Ducted | 1.80 | 78% | 9.0 | 14.3 | ES CC | 2 | 215748029 |
| CNTM16DHP36AAConnect M · CNTM Serieswith ducted air handler CNTMDCC36AA | 3 tons35,000 Btu/h · Ducted | 2.00 | 82% | 10.0 | 15.2 | CEE 25CEE 26XcelES CC | 2 | 215748028 |
| CNTM16DHP18AAConnect M · CNTM Serieswith ducted air handler CNTMDCC24AA | 1.5 tons18,000 Btu/h · Ducted | 2.20 | 79% | 9.5 | 16.1 | CEE 25CEE 26XcelES CC | 2 | 215748027 |
| CNTM16DHP24AAConnect M · CNTM Serieswith ducted air handler CNTM16DAH24AA | 2 tons24,000 Btu/h · Ducted | 1.91 | 94% | 10.0 | 17.4 | CEE 25CEE 26XcelES CC | 1 | 215748023 |
Compare Connect M