- Insights
- Manufacturers
- cool-living
Both views use the same certified data. This device remembers your choice.
cool-living heat pump efficiency: 5 outdoor models compared
cool-living has 5 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes cool-living makes. cool-living has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 5
- AHRI certifications
- 5
- Efficiency index
- 41%
- Typical model vs same-size, same-type peers (5 models)
- Meet CEE 2025
- 100%
- 5 models
How cool-living compares with comparable models
- cool-living
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index5 models scored | 41% | Not ranked | — |
| COP at 5°F5 models scored | 23% | Not ranked | 1.80 |
| Capacity retention at 5°F5 models scored | 44% | Not ranked | 70% |
| HSPF25 models scored | 37% | Not ranked | 9.0 |
| SEER25 models scored | 47% | Not ranked | 20.0 |
| EER25 models scored | 47% | Not ranked | 12.5 |
| Heating capacity at 5°F5 models scored | 42% | Not ranked | 9,100 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 5 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 5 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 60% | 3 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- cool-living (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 4 | 39% | 22% | 33% | 47% |
| Non-ducted, 2 tons | 1 | 48% | 31% | 50% | 47% |
Every cool-living model in the market
- cool-living models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 179 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 354 | 1.85 | 1.89 | 2.00 | 2.40 | 2.63 |
| Ducted, 1.5 tons | 802 | 1.75 | 1.85 | 2.00 | 2.20 | 2.52 |
| Ducted, 2 tons | 791 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 758 | 1.70 | 1.80 | 1.90 | 2.10 | 2.44 |
| Ducted, 3 tons | 674 | 1.68 | 1.73 | 1.90 | 2.06 | 2.34 |
| Ducted, 3.5 tons | 662 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 373 | 1.70 | 1.80 | 1.91 | 2.02 | 2.50 |
| Ducted, 4.5 tons | 575 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 29 | 1.80 | 1.80 | 1.86 | 1.90 | 2.10 |
| Non-ducted, 0.5 tons | 774 | 1.75 | 1.80 | 1.94 | 2.09 | 2.19 |
| Non-ducted, 1 ton | 1,135 | 1.75 | 1.80 | 1.89 | 2.07 | 2.24 |
| Non-ducted, 1.5 tons | 946 | 1.75 | 1.80 | 1.87 | 2.07 | 2.20 |
| Non-ducted, 2 tons | 598 | 1.78 | 1.80 | 1.83 | 2.00 | 2.21 |
| Non-ducted, 2.5 tons | 327 | 1.75 | 1.80 | 1.84 | 1.86 | 2.02 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.80 | 1.90 | 2.00 | 2.07 |
| Non-ducted, 3.5 tons | 71 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 269 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 106 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 31 | 1.89 | 2.00 | 2.07 | 2.30 | 2.40 |
Source: AHRI Directory · as of
Top cool-living models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CL-12HA2-OUTcool-living · TPROwith ductless indoor unit CL-12HA2-IN | 1 ton12,000 Btu/h · Non-ducted | 76% | 1.80 | 9.5 | 9,100 | 23.0 | CEE 25CEE 26Xcel | 1 | 213968905 | Non-ducted, up to 1.5 tons | 49.6 |
| 2CL-12HA1-OUTcool-livingwith ductless indoor unit CL-12HA1-IN | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.80 | 8.5 | 8,600 | 19.0 | CEE 25CEE 26Xcel | 1 | 213928542 | Non-ducted, up to 1.5 tons | 30.5 |
| 3CL-09HA1-OUTcool-livingwith ductless indoor unit CL-09HA1-IN | 1 ton9,000 Btu/h · Non-ducted | 70% | 1.75 | 8.5 | 7,000 | 19.0 | CEE 25CEE 26Xcel | 1 | 213928541 | Non-ducted, up to 1.5 tons | 22.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CL-12HA2-OUTcool-living · TPROwith ductless indoor unit CL-12HA2-IN | 1 ton12,000 Btu/h · Non-ducted | 76% | 1.80 | 9.5 | 23.0 | 13.0 | CEE 25CEE 26Xcel | 1 | 213968905 | Non-ducted, up to 1.5 tons | 61.3 | 49.6 | 73.1 | 49.6 |
| 2CL-18HA2-OUTcool-living · TPROwith ductless indoor unit CL-18HA2-IN | 1.5 tons18,000 Btu/h · Non-ducted | 66% | 1.80 | 9.0 | 22.0 | 13.0 | CEE 25CEE 26 | 1 | 213968906 | Non-ducted, up to 1.5 tons | 49.2 | 31.3 | 67.1 | Not a pick |
| 3CL-24HA2-OUTcool-living · TPROwith ductless indoor unit CL-24HA2-IN | 2 tons23,000 Btu/h · Non-ducted | 67% | 1.80 | 9.0 | 20.0 | 12.5 | CEE 25CEE 26 | 1 | 213968907 | Non-ducted, 2 tons | 47.6 | 38.9 | 56.3 | Not a pick |
| 4CL-12HA1-OUTcool-livingwith ductless indoor unit CL-12HA1-IN | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.80 | 8.5 | 19.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 213928542 | Non-ducted, up to 1.5 tons | 24.8 | 30.5 | 19.1 | 30.5 |
| 5CL-09HA1-OUTcool-livingwith ductless indoor unit CL-09HA1-IN | 1 ton9,000 Btu/h · Non-ducted | 70% | 1.75 | 8.5 | 19.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 213928541 | Non-ducted, up to 1.5 tons | 20.7 | 22.4 | 19.1 | 22.4 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CL-24HA2-OUT | 1.80 | Non-ducted, 2 tons | 31% | 213968907 |
| Capacity retention at 5°F | CL-12HA2-OUT | 76% | Non-ducted, up to 1.5 tons | 62% | 213968905 |
| HSPF2 | CL-12HA2-OUT | 9.5 | Non-ducted, up to 1.5 tons | 58% | 213968905 |
| SEER2 | CL-12HA2-OUT | 23.0 | Non-ducted, up to 1.5 tons | 73% | 213968905 |
| EER2 | CL-12HA2-OUT | 13.0 | Non-ducted, up to 1.5 tons | 68% | 213968905 |
| Heating capacity at 5°F | CL-18HA2-OUT | 11,900 Btu/h | Non-ducted, up to 1.5 tons | 67% | 213968906 |
cool-living size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 49.6(50 is the typical model of its size class)CL-12HA2-OUTwith ductless indoor unit CL-12HA2-IN3 of 4 models qualify · AHRI 213968905 | 61.3(50 is the typical model of its size class)CL-12HA2-OUTwith ductless indoor unit CL-12HA2-IN4 of 4 models have all five ratings · AHRI 213968905 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 47.6(50 is the typical model of its size class)CL-24HA2-OUTwith ductless indoor unit CL-24HA2-IN1 of 1 models have all five ratings · AHRI 213968907 |
Newest cool-living certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CL-24HA2-OUTcool-living · TPROwith ductless indoor unit CL-24HA2-IN | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 67% | 9.0 | 20.0 | CEE 25CEE 26 | 1 | 213968907 |
| CL-18HA2-OUTcool-living · TPROwith ductless indoor unit CL-18HA2-IN | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 66% | 9.0 | 22.0 | CEE 25CEE 26 | 1 | 213968906 |
| CL-12HA2-OUTcool-living · TPROwith ductless indoor unit CL-12HA2-IN | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 76% | 9.5 | 23.0 | CEE 25CEE 26Xcel | 1 | 213968905 |
| CL-12HA1-OUTcool-livingwith ductless indoor unit CL-12HA1-IN | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 213928542 |
| CL-09HA1-OUTcool-livingwith ductless indoor unit CL-09HA1-IN | 1 ton9,000 Btu/h · Non-ducted | 1.75 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 213928541 |
Compare cool-living
cool-living includes these brand names as listed in AHRI: cool-living. Standards are checked against published thresholds; program rules beyond ratings are not checked.