Dettson heat pump efficiency: 10 outdoor models compared
Dettson has 10 heat pump outdoor models certified with this refrigerant group, in 36 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Dettson makes. Dettson has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 10
- AHRI certifications
- 36
- Efficiency index
- 52%
- Typical model vs same-size, same-type peers (10 models)
- Meet CEE 2025
- 60%
- 6 models
How Dettson compares with comparable models
- Dettson
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index10 models scored | 52% | Not ranked | — |
| COP at 5°F10 models scored | 55% | Not ranked | 2.00 |
| Capacity retention at 5°F10 models scored | 71% | Not ranked | 82% |
| HSPF210 models scored | 78% | Not ranked | 9.6 |
| SEER210 models scored | 42% | Not ranked | 15.4 |
| EER210 models scored | 30% | Not ranked | 10.6 |
| Heating capacity at 5°F10 models scored | 80% | Not ranked | 25,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 60% | 6 |
| CEE 2026 Tier 1 (Split ASHP) | 60% | 6 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 80% | 8 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 100% | 10 |
Sizes and duct types offered
- Dettson (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 3 | 51% | 69% | 66% | 34% |
| Ducted, 2 tons | 2 | 57% | 57% | 84% | 42% |
| Ducted, 2.5–3 tons | 3 | 49% | 47% | 79% | 39% |
| Ducted, 3.5–4.5 tons | 2 | 53% | 45% | 88% | 58% |
Every Dettson model in the market
- Dettson models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top Dettson models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1EVD-36-ODettson · EVD serieswith ducted air handler MAC36H2124E | 3 tons35,000 Btu/h · Ducted | 82% | 2.00 | 10.0 | 32,000 | 15.2 | CEE 25CEE 26XcelES CC | 9 | 213160483 | Ducted, 2.5–3 tons | 78.6 |
| 2MHD-24Dettson · MHD serieswith ducted air handler MHD-CC2.0-17.5-M | 2 tons23,000 Btu/h · Ducted | 93% | 2.08 | 9.8 | 23,000 | 15.2 | XcelES CC | 2 | 210365428 | Ducted, 2 tons | 75.6 |
| 3EVD-48-ODettson · EVD serieswith ducted air handler EVD-48-I | 4 tons47,000 Btu/h · Ducted | 92% | 1.90 | 9.4 | 46,000 | 15.6 | ES CC | 2 | 210365435 | Ducted, 3.5–4.5 tons | 73.8 |
| 4EVD-60-ODettson · EVD serieswith ducted air handler EVD-60-I | 4.5 tons55,000 Btu/h · Ducted | 82% | 1.91 | 9.4 | 48,500 | 15.3 | ES CC | 2 | 210365436 | Ducted, 3.5–4.5 tons | 71.3 |
| 5EVD-30-ODettsonwith ducted air handler *G8J936+TD | 2.5 tons29,800 Btu/h · Ducted | 86% | 1.85 | 9.5 | 27,000 | 15.2 | CEE 25CEE 26XcelES CC | 7 | 213369636 | Ducted, 2.5–3 tons | 69.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1EVD-36-O-SDettson · EVD serieswith ducted air handler EVD-36-I | 3 tons35,000 Btu/h · Ducted | 97% | 1.80 | 9.5 | 16.3 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 213488871 | Ducted, 2.5–3 tons | 68.5 | 68.9 | 68.1 | 68.9 |
| 2EVD-24-ODettson · EVD serieswith ducted air handler EVD-24-I | 2 tons24,000 Btu/h · Ducted | 94% | 1.91 | 10.0 | 17.4 | 11.7 | CEE 25CEE 26XcelES CC | 4 | 210365432 | Ducted, 2 tons | 65.8 | 66.5 | 65.1 | 66.5 |
| 3EVD-18-ODettson · EVD serieswith ducted air handler EVD-18-I | 1.5 tons18,000 Btu/h · Ducted | 87% | 2.04 | 9.3 | 18.0 | 12.4 | CEE 25CEE 26XcelES CC | 4 | 210365431 | Ducted, up to 1.5 tons | 63.4 | 60.4 | 66.3 | 63.7 |
| 4MHD-24Dettson · MHD serieswith ducted air handler MHD-CC2.0-17.5-M | 2 tons23,000 Btu/h · Ducted | 93% | 2.08 | 9.8 | 15.2 | 11.7 | XcelES CC | 2 | 210365428 | Ducted, 2 tons | 60.0 | 75.6 | 44.4 | 75.6 |
| 5EVD-36-ODettson · EVD serieswith ducted air handler EVD-36-I | 3 tons36,000 Btu/h · Ducted | 86% | 1.97 | 9.5 | 16.0 | 10.0 | CEE 25CEE 26XcelES CC | 9 | 210365434 | Ducted, 2.5–3 tons | 56.1 | 74.7 | 37.6 | 78.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | MHD-18 | 2.21 | Ducted, up to 1.5 tons | 79% | 210365427 |
| Capacity retention at 5°F | EVD-48-O | 92% | Ducted, 3.5–4.5 tons | 92% | 210365435 |
| HSPF2 | EVD-36-O | 10.0 | Ducted, 2.5–3 tons | 93% | 213160483 |
| SEER2 | EVD-24-O | 17.4 | Ducted, 2 tons | 67% | 210365432 |
| EER2 | EVD-18-O | 12.4 | Ducted, up to 1.5 tons | 72% | 210365431 |
| Heating capacity at 5°F | EVD-36-O-S | 38,000 Btu/h | Ducted, 2.5–3 tons | 96% | 213488871 |
Dettson size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 65.2(50 is the typical model of its size class)EVD-24-O*with ducted air handler MAC24H1418E3 of 3 models qualify · AHRI 213386698 | 63.4(50 is the typical model of its size class)EVD-18-Owith ducted air handler EVD-18-I3 of 3 models have all five ratings · AHRI 210365431 |
| Ducted, 2 tons | 75.6(50 is the typical model of its size class)MHD-24with ducted air handler MHD-CC2.0-17.5-M2 of 2 models qualify · AHRI 210365428 | 65.8(50 is the typical model of its size class)EVD-24-Owith ducted air handler EVD-24-I2 of 2 models have all five ratings · AHRI 210365432 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class)EVD-36-Owith ducted air handler MAC36H2124E3 of 3 models qualify · AHRI 213160483 | 68.5(50 is the typical model of its size class)EVD-36-O-Swith ducted air handler EVD-36-I3 of 3 models have all five ratings · AHRI 213488871 |
| Ducted, 3.5–4.5 tons | 73.8(50 is the typical model of its size class)EVD-48-Owith ducted air handler EVD-48-I2 of 2 models qualify · AHRI 210365435 | 53.3(50 is the typical model of its size class)EVD-60-Owith ducted air handler EVD-60-I2 of 2 models have all five ratings · AHRI 210365436 |
Newest Dettson certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| EVD-30-ODettson · EVD Serieswith ducted air handler MAC36H1724E | 2.5 tons29,000 Btu/h · Ducted | 1.80 | 73% | 8.5 | 15.2 | CEE 25CEE 26XcelES CC | 7 | 218469227 |
| EVD-36-O-SDettson · EVD serieswith ducted air handler EVD-36-I | 3 tons35,000 Btu/h · Ducted | 1.80 | 97% | 9.5 | 16.3 | CEE 25CEE 26XcelES CC | 3 | 213488871 |
| EVD-24-ODettson · EVD serieswith ducted air handler MAC24H1418E | 2 tons24,000 Btu/h · Ducted | 2.00 | 80% | 9.8 | 16.1 | CEE 25CEE 26XcelES CC | 4 | 213386699 |
| EVD-24-O*Dettson · EVD serieswith ducted air handler MAC24H1418E | 1.5 tons20,000 Btu/h · Ducted | 2.00 | 80% | 10.2 | 16.3 | CEE 25CEE 26XcelES CC | 1 | 213386698 |
| EVD-36-ODettsonwith ducted air handler *G8J936+TD | 3 tons34,600 Btu/h · Ducted | 1.80 | 77% | 8.5 | 15.2 | CEE 25CEE 26XcelES CC | 9 | 213369639 |
Compare Dettson