Skip to content

DNAIR heat pump efficiency: 5 outdoor models compared

DNAIR has 5 heat pump outdoor models certified with this refrigerant group, in 9 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes DNAIR makes. DNAIR has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
5
AHRI certifications
9
Efficiency index
49%
Typical model vs same-size, same-type peers (5 models)
Meet CEE 2025
80%
4 models

How DNAIR compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
DNAIR against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of DNAIR’s own modelsDNAIR is strongest on HSPF2 (its typical model beats 78% of comparable models) and weakest on EER2 (26%).
  • DNAIR
  • Middle half of its models
  • Other ranked manufacturers
DNAIR

Source: AHRI Directory, NEEP · as of

Average peer percentile of DNAIR’s models
RatingBeats comparable modelsRankRaw median
Efficiency index5 models scored49%Not ranked—
COP at 5°F5 models scored50%Not ranked1.95
Capacity retention at 5°F5 models scored68%Not ranked80%
HSPF25 models scored78%Not ranked9.5
SEER25 models scored39%Not ranked15.5
EER25 models scored26%Not ranked10.5
Heating capacity at 5°F5 models scored74%Not ranked27,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
DNAIR’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • DNAIR (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons152%76%58%37%
Ducted, 2 tons151%37%77%58%
Ducted, 2.5–3 tons253%56%91%41%
Ducted, 3.5–4.5 tons137%25%74%21%

Every DNAIR model in the market

DNAIR’s 5 models with a known size and duct type, over the shape of the whole catalog.
DNAIR models by size and ratingColoured: DNAIR · grey shapes: all 11,475 models · lines: catalog medians by size
  • DNAIR models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 5 dnair models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top DNAIR models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 DNAIR cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1DNHP0036H-CDNAIRwith ducted air handler DNCL0036H-E3 tons35,000 Btu/h · Ducted82%2.0010.032,00015.2CEE 25CEE 26Xcel2213350749Ducted, 2.5–3 tons78.6
2DNHP0030H-CDNAIRwith ducted air handler DNCL0030H-E2.5 tons30,000 Btu/h · Ducted82%1.859.727,00015.5CEE 25CEE 26Xcel2213350748Ducted, 2.5–3 tons67.8
3DNHP0024H-CDNAIRwith ducted air handler DNHU0024H-E2 tons24,000 Btu/h · Ducted94%1.9110.022,60017.4CEE 25CEE 26Xcel2213350743Ducted, 2 tons66.5
4DNHP0018H-CDNAIRwith ducted air handler DNCL0018H-E1.5 tons18,000 Btu/h · Ducted79%2.209.515,00016.1CEE 25CEE 26Xcel2213350746Ducted, up to 1.5 tons63.7
5DNHP0048H-CDNAIRwith ducted air handler DNCL0048H-E4 tons46,000 Btu/h · Ducted78%1.809.040,00014.3None1213350750Ducted, 3.5–4.5 tons57.4

All-around best

Top 5 DNAIR models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1DNHP0024H-CDNAIRwith ducted air handler DNHU0024H-E2 tons24,000 Btu/h · Ducted94%1.9110.017.411.7CEE 25CEE 26Xcel2213350743Ducted, 2 tons65.866.565.166.5
2DNHP0018H-CDNAIRwith ducted air handler DNHU0018H-E1.5 tons18,000 Btu/h · Ducted87%2.049.318.012.4CEE 25CEE 26Xcel2213350742Ducted, up to 1.5 tons63.460.466.363.7
3DNHP0036H-CDNAIRwith ducted air handler DNHU0036H-E3 tons36,000 Btu/h · Ducted86%1.979.516.010.0CEE 25CEE 26Xcel2213350745Ducted, 2.5–3 tons56.174.737.678.6
4DNHP0030H-CDNAIRwith ducted air handler DNCL0030H-E2.5 tons30,000 Btu/h · Ducted82%1.859.715.510.5CEE 25CEE 26Xcel2213350748Ducted, 2.5–3 tons52.667.837.467.8
5DNHP0048H-CDNAIRwith ducted air handler DNCL0048H-E4 tons46,000 Btu/h · Ducted78%1.809.014.38.6None1213350750Ducted, 3.5–4.5 tons37.057.416.757.4

Best model on each rating

DNAIR’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FDNHP0018H-C2.20Ducted, up to 1.5 tons76%213350746
Capacity retention at 5°FDNHP0036H-C86%Ducted, 2.5–3 tons74%213350745
HSPF2DNHP0036H-C10.0Ducted, 2.5–3 tons93%213350749
SEER2DNHP0024H-C17.4Ducted, 2 tons67%213350743
EER2DNHP0018H-C12.4Ducted, up to 1.5 tons72%213350742
Heating capacity at 5°FDNHP0036H-C34,400 Btu/hDucted, 2.5–3 tons89%213350745

All 5 DNAIR models in Explore

DNAIR size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
DNAIR: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons63.7(50 is the typical model of its size class)DNHP0018H-Cwith ducted air handler DNCL0018H-E1 of 1 models qualify · AHRI 21335074663.4(50 is the typical model of its size class)DNHP0018H-Cwith ducted air handler DNHU0018H-E1 of 1 models have all five ratings · AHRI 213350742
Ducted, 2 tons66.5(50 is the typical model of its size class)DNHP0024H-Cwith ducted air handler DNHU0024H-E1 of 1 models qualify · AHRI 21335074365.8(50 is the typical model of its size class)DNHP0024H-Cwith ducted air handler DNHU0024H-E1 of 1 models have all five ratings · AHRI 213350743
Ducted, 2.5–3 tons78.6(50 is the typical model of its size class)DNHP0036H-Cwith ducted air handler DNCL0036H-E2 of 2 models qualify · AHRI 21335074956.1(50 is the typical model of its size class)DNHP0036H-Cwith ducted air handler DNHU0036H-E2 of 2 models have all five ratings · AHRI 213350745
Ducted, 3.5–4.5 tons57.4(50 is the typical model of its size class)DNHP0048H-Cwith ducted air handler DNCL0048H-E1 of 1 models qualify · AHRI 21335075037.0(50 is the typical model of its size class)DNHP0048H-Cwith ducted air handler DNCL0048H-E1 of 1 models have all five ratings · AHRI 213350750

All-around board, every manufacturer

Newest DNAIR certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified DNAIR outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
DNHP0048H-CDNAIRwith ducted air handler DNCL0048H-E4 tons46,000 Btu/h · Ducted1.8078%9.014.3None1213350750
DNHP0036H-CDNAIRwith ducted air handler DNCL0036H-E3 tons35,000 Btu/h · Ducted2.0082%10.015.2CEE 25CEE 26Xcel2213350749
DNHP0030H-CDNAIRwith ducted air handler DNCL0030H-E2.5 tons30,000 Btu/h · Ducted1.8582%9.715.5CEE 25CEE 26Xcel2213350748
DNHP0024H-CDNAIRwith ducted air handler DNCL0024H-E2 tons24,000 Btu/h · Ducted1.9580%9.516.5CEE 25CEE 26Xcel2213350747
DNHP0018H-CDNAIRwith ducted air handler DNCL0018H-E1.5 tons18,000 Btu/h · Ducted2.2079%9.516.1CEE 25CEE 26Xcel2213350746

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare DNAIR

Manufacturers of a similar size, side by side.

DNAIR includes these brand names as listed in AHRI: DNAIR. Standards are checked against published thresholds; program rules beyond ratings are not checked.