E COLD heat pump efficiency: 5 outdoor models compared
E COLD has 5 heat pump outdoor models certified with this refrigerant group, in 26 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes E COLD makes. E COLD has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 5
- AHRI certifications
- 26
- Efficiency index
- 55%
- Typical model vs same-size, same-type peers (9 models)
- Meet CEE 2025
- 80%
- 4 models
How E COLD compares with comparable models
- E COLD
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index9 models scored | 55% | Not ranked | — |
| COP at 5°F9 models scored | 28% | Not ranked | 1.80 |
| Capacity retention at 5°F9 models scored | 45% | Not ranked | 69% |
| HSPF29 models scored | 62% | Not ranked | 9.5 |
| SEER29 models scored | 77% | Not ranked | 21.1 |
| EER29 models scored | 53% | Not ranked | 10.6 |
| Heating capacity at 5°F9 models scored | 44% | Not ranked | 25,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 80% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 60% | 3 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 40% | 2 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- E COLD (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, 2.5–3 tons | 2 | 64% | 24% | 75% | 95% |
| Ducted, 3.5–4.5 tons | 2 | 58% | 10% | 82% | 93% |
| Non-ducted, 2.5–3 tons | 3 | 53% | 47% | 46% | 68% |
| Non-ducted, 3.5–4.5 tons | 2 | 46% | 22% | 52% | 56% |
Every E COLD model in the market
- E COLD models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top E COLD models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ECOLD-C27-MS-G0001E·COLD | 2.5 tons28,000 Btu/h · Ducted | 71% | 1.83 | 9.2 | 20,000 | 21.0 | CEE 25CEE 26Xcel | 6 | 213350752 | Ducted, 2.5–3 tons | 57.8 |
| 2ECOLD-C27-MS-G0001E·COLD | 2.5 tons27,000 Btu/h · Non-ducted | 71% | 1.83 | 9.2 | 20,000 | 23.5 | CEE 25CEE 26Xcel | 6 | 213350751 | Non-ducted, 2.5–3 tons | 50.1 |
| 3ECOLD-C48-MS-G0001E·COLD | 4 tons48,000 Btu/h · Non-ducted | 71% | 1.80 | 9.5 | 34,000 | 21.1 | CEE 25CEE 26Xcel | 6 | 213350757 | Non-ducted, 3.5–4.5 tons | 39.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ECOLD-C27-MS-G0001E·COLD | 2.5 tons28,000 Btu/h · Ducted | 71% | 1.83 | 9.2 | 21.0 | 11.7 | CEE 25CEE 26Xcel | 6 | 213350752 | Ducted, 2.5–3 tons | 71.7 | 57.8 | 85.6 | 57.8 |
| 2ECOLD-C27-MS-G0001E·COLD | 2.5 tons27,000 Btu/h · Non-ducted | 71% | 1.83 | 9.2 | 23.5 | 12.2 | CEE 25CEE 26Xcel | 6 | 213350751 | Non-ducted, 2.5–3 tons | 67.1 | 50.1 | 84.1 | 50.1 |
| 3ECOLD-C48-MS-G0001E·COLD | 4 tons48,000 Btu/h · Ducted | 66% | 1.70 | 9.7 | 20.5 | 10.8 | None | 6 | 213350758 | Ducted, 3.5–4.5 tons | 63.5 | 53.5 | 73.6 | Not a pick |
| 4ECOLD-C36-MS-G0001E·COLD | 3 tons36,000 Btu/h · Ducted | 65% | 1.68 | 9.2 | 20.0 | 11.0 | None | 6 | 213350755 | Ducted, 2.5–3 tons | 56.6 | 43.7 | 69.4 | Not a pick |
| 5ECOLD-C36-MS-G0001E·COLD | 3 tons36,000 Btu/h · Non-ducted | 69% | 1.80 | 9.6 | 23.1 | 10.6 | CEE 25CEE 26 | 6 | 213350754 | Non-ducted, 2.5–3 tons | 56.0 | 44.3 | 67.6 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ECOLD-C36BRISA-G002 | 2.01 | Non-ducted, 2.5–3 tons | 87% | 213363375 |
| Capacity retention at 5°F | ECOLD-C27-MS-G0001 | 71% | Non-ducted, 2.5–3 tons | 57% | 213350751 |
| HSPF2 | ECOLD-C48-MS-G0001 | 9.7 | Ducted, 3.5–4.5 tons | 95% | 213350758 |
| SEER2 | ECOLD-C27-MS-G0001 | 21.0 | Ducted, 2.5–3 tons | 98% | 213350752 |
| EER2 | ECOLD-C27-MS-G0001 | 12.2 | Non-ducted, 2.5–3 tons | 75% | 213350751 |
| Heating capacity at 5°F | ECOLD-C36-MS-G0001 | 25,600 Btu/h | Non-ducted, 2.5–3 tons | 69% | 213350754 |
E COLD size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, 2.5–3 tons | 57.8(50 is the typical model of its size class)ECOLD-C27-MS-G00011 of 2 models qualify · AHRI 213350752 | 71.7(50 is the typical model of its size class)ECOLD-C27-MS-G00012 of 2 models have all five ratings · AHRI 213350752 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 2 models qualify) | 63.5(50 is the typical model of its size class)ECOLD-C48-MS-G00012 of 2 models have all five ratings · AHRI 213350758 |
| Non-ducted, 2.5–3 tons | 50.1(50 is the typical model of its size class)ECOLD-C27-MS-G00011 of 3 models qualify · AHRI 213350751 | 67.1(50 is the typical model of its size class)ECOLD-C27-MS-G00013 of 3 models have all five ratings · AHRI 213350751 |
| Non-ducted, 3.5–4.5 tons | 39.4(50 is the typical model of its size class)ECOLD-C48-MS-G00011 of 2 models qualify · AHRI 213350757 | 51.7(50 is the typical model of its size class)ECOLD-C48-MS-G00012 of 2 models have all five ratings · AHRI 213350757 |
Newest E COLD certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| ECOLD-C36BRISA-G002E COLDwith ductless indoor unit ECOLD-E36BRISA-G002 | 3 tons36,000 Btu/h · Non-ducted | 2.01 | 61% | 7.8 | 18.0 | None | 2 | 213828451 |
| ECOLD-C55-MS-G0001E COLD | 4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.75 | 62% | 9.1 | 19.6 | CEE 25 | 6 | 213828450 |
| ECOLD-C48-MS-G0001E COLD | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.75 | 69% | 9.6 | 20.8 | CEE 25CEE 26Xcel | 6 | 213828447 |
| ECOLD-C36-MS-G0001E COLD | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.74 | 65% | 9.4 | 21.6 | CEE 25CEE 26 | 6 | 213828444 |
| ECOLD-C27-MS-G0001E COLD | 2.5 tons27,400 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.83 | 71% | 9.2 | 22.3 | CEE 25CEE 26Xcel | 6 | 213828441 |
Compare E COLD
E COLD includes these brand names as listed in AHRI: E COLD. Standards are checked against published thresholds; program rules beyond ratings are not checked.