Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Ecoer heat pump efficiency: 13 outdoor models compared
Ecoer has 13 heat pump outdoor models certified with this refrigerant group, in 375 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Ecoer makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 13
- AHRI certifications
- 375
- Efficiency index
- 70%
- Typical model vs same-size, same-type peers (13 models)
- Meet CEE 2025
- 92.3%
- 12 models
How Ecoer compares with comparable models
- Ecoer
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index13 models scored | 70% | 1st of 27 | — |
| COP at 5°F13 models scored | 74% | 1st of 27 | 2.10 |
| Capacity retention at 5°F13 models scored | 67% | 2nd of 27 | 82% |
| HSPF213 models scored | 72% | 1st of 27 | 9.2 |
| SEER213 models scored | 74% | 1st of 27 | 18.5 |
| EER213 models scored | 66% | 2nd of 27 | 12.0 |
| Heating capacity at 5°F13 models scored | 70% | 2nd of 27 | 29,200 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 92.3% | 12 |
| CEE 2026 Tier 1 (Split ASHP) | 92.3% | 12 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100% | 13 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 46.2% | 6 |
Sizes and duct types offered
- Ecoer (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 2 | 55% | 96% | 39% | 43% |
| Ducted, 2 tons | 3 | 84% | 67% | 76% | 95% |
| Ducted, 2.5–3 tons | 2 | 67% | 74% | 84% | 60% |
| Ducted, 3.5–4.5 tons | 6 | 70% | 70% | 76% | 78% |
Every Ecoer model in the market
- Ecoer models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top Ecoer models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1EODA19H-4860AECOERwith ducted air handler EAHATN-48BAlso listed as EODA19H-4860AA | 4 tons47,000 Btu/h · Ducted | 72% | 2.10 | 9.5 | 34,400 | 19.0 | CEE 25CEE 26Xcel | 18 | 214303510 | Ducted, 3.5–4.5 tons | 78.6 |
| 2ESCA16H-36Ecoer · SDi Decades Extremewith ducted air handler SNC36CPT | 3 tons35,000 Btu/h · Ducted | 82% | 2.00 | 10.0 | 32,000 | 15.2 | CEE 25CEE 26XcelES CC | 2 | 213386490 | Ducted, 2.5–3 tons | 78.6 |
| 3EODA18H-4860BECOERwith ducted air handler AE(D,N,U)+CM48A34+TDR | 3.5 tons40,000 Btu/h · Ducted | 84% | 2.39 | 8.3 | 38,500 | 17.6 | CEE 25CEE 26Xcel | 56 | 213885838 | Ducted, 3.5–4.5 tons | 76.0 |
| 4EODA18H-4860BAAECOER · ESi Decades Extremewith ducted air handler EAHATN-36BAA | 3 tons35,200 Btu/h · Ducted | 81% | 2.10 | 9.2 | 29,200 | 19.0 | CEE 25CEE 26Xcel | 53 | 214608195 | Ducted, 2.5–3 tons | 74.6 |
| 5EODA18H-2436BECOERwith indoor coil D(A,C,E)24C34+TDR and furnace MGH96M060B3AAlso listed as EODA18H-2436BAA | 2 tons22,800 Btu/h · Ducted | 98% | 2.10 | 8.8 | 23,600 | 18.0 | CEE 25CEE 26Xcel | 45 | 214592558 | Ducted, up to 1.5 tons | 71.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1EODA19H-4860AECOERwith ducted air handler EAHATN-48BAlso listed as EODA19H-4860AA | 4 tons47,000 Btu/h · Ducted | 72% | 2.10 | 9.5 | 19.0 | 12.5 | CEE 25CEE 26Xcel | 18 | 214303510 | Ducted, 3.5–4.5 tons | 86.4 | 78.6 | 94.2 | 78.6 |
| 2EODA19H-2436AECOERwith ducted air handler EAHATN-24BAlso listed as EODA19H-2436AA | 2 tons24,000 Btu/h · Ducted | 82% | 2.10 | 9.5 | 20.5 | 13.0 | CEE 25CEE 26Xcel | 19 | 214303508 | Ducted, 2 tons | 84.1 | 71.4 | 96.8 | 71.4 |
| 3EODA18H-2436BECOER · ESi Decades Extremewith ducted air handler EAHATN-24BAlso listed as EODA18H-2436BAA | 2 tons24,000 Btu/h · Ducted | 82% | 2.10 | 9.2 | 20.0 | 13.0 | CEE 25CEE 26Xcel | 45 | 207861756 | Ducted, up to 1.5 tons | 82.9 | 69.6 | 96.2 | 71.9 |
| 4EODA18H-4860BECOER · ESi Decades Extremewith ducted air handler EAHATN-36BAlso listed as EODA18H-4860BAA | 3 tons35,200 Btu/h · Ducted | 81% | 2.10 | 9.2 | 19.0 | 12.0 | CEE 25CEE 26Xcel | 56 | 207861758 | Ducted, 3.5–4.5 tons | 80.4 | 74.6 | 86.1 | 76.0 |
| 5EODA18H-4860ECOER · ESi Decadeswith ducted air handler EAHATN-36B | 3 tons36,000 Btu/h · Ducted | 78% | 2.10 | 8.5 | 18.0 | 12.0 | CEE 25CEE 26Xcel | 31 | 211887780 | Ducted, 3.5–4.5 tons | 75.3 | 67.7 | 82.9 | 67.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | EODA18H-2436 | 2.82 | Ducted, up to 1.5 tons | 98% | 213885835 |
| Capacity retention at 5°F | EODA19H-4860AA* | 100% | Ducted, 3.5–4.5 tons | 98% | 217361951 |
| HSPF2 | ESCA16H-36 | 10.0 | Ducted, 2.5–3 tons | 93% | 213386490 |
| SEER2 | EODA19H-2436AAlso listed as EODA19H-2436AA | 20.5 | Ducted, 2 tons | 95% | 214303508 |
| EER2 | EODA18H-2436BAlso listed as EODA18H-2436BAA | 13.0 | Ducted, 2 tons | 95% | 207861756 |
| Heating capacity at 5°F | ESCA16H-60 | 48,500 Btu/h | Ducted, 3.5–4.5 tons | 95% | 211594474 |
Ecoer size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 63.5(50 is the typical model of its size class)EODA18H-2436with ducted air handler AE(D,N,U)+CM30B24+TDR1 of 1 models qualify · AHRI 213885835 | No models in this size class |
| Ducted, 2 tons | 71.9(50 is the typical model of its size class)EODA18H-2436Bwith indoor coil D(A,C,E)24C34+TDR and furnace MGH96M060B3AAlso listed as EODA18H-2436BAA4 of 4 models qualify · AHRI 214592558 | 84.1(50 is the typical model of its size class)EODA19H-2436Awith ducted air handler EAHATN-24BAlso listed as EODA19H-2436AA5 of 5 models have all five ratings · AHRI 214303508 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class)ESCA16H-36with ducted air handler SNC36CPT3 of 3 models qualify · AHRI 213386490 | 80.4(50 is the typical model of its size class)EODA18H-4860Bwith ducted air handler EAHATN-36BAlso listed as EODA18H-4860BAA4 of 4 models have all five ratings · AHRI 207861758 |
| Ducted, 3.5–4.5 tons | 78.6(50 is the typical model of its size class)EODA19H-4860Awith ducted air handler EAHATN-48BAlso listed as EODA19H-4860AA5 of 5 models qualify · AHRI 214303510 | 86.4(50 is the typical model of its size class)EODA19H-4860Awith ducted air handler EAHATN-48BAlso listed as EODA19H-4860AA4 of 4 models have all five ratings · AHRI 214303510 |
Newest Ecoer certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| EODA19H-4860AA*ECOER · TDi Prowith indoor coil SNC36CPT and furnace MGH96M080C4A | 3 tons33,000 Btu/h · Ducted | 1.95 | 80% | 9.0 | 18.0 | CEE 25CEE 26XcelES CC | 37 | 217477695 |
| EODA19H-2436AA*ECOER · TDi Prowith indoor coil SNC36CPT and furnace MGH96M080C4A | 3 tons33,000 Btu/h · Ducted | 1.95 | 71% | 9.0 | 18.0 | CEE 25CEE 26XcelES CC | 38 | 217477694 |
| EODA18H-4860ECOER · ESi Decadeswith indoor coil GNC4860CPT and furnace FG7SA-108C-T35C | 4.5 tons51,000 Btu/h · Ducted | 1.90 | 70% | 8.1 | 16.0 | CEE 25CEE 26Xcel | 31 | 217374089 |
| EODA18H-2436ECOER · ESi Decadeswith indoor coil GNC4248CPT and furnace FG7SA-090C-T35C | 2.5 tons32,000 Btu/h · Ducted | 2.00 | 68% | 8.2 | 16.0 | CEE 25CEE 26Xcel | 22 | 217374084 |
| EODA18H-4860BECOERwith ducted air handler M4860C*1-B*+M4860B*1-EC | 3.5 tons42,000 Btu/h · Ducted | 1.68 | 53% | 8.6 | 12.6 | CEE 25CEE 26Xcel | 56 | 216612239 |
Compare Ecoer