- Insights
- Manufacturers
- GE Appliances
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
GE Appliances heat pump efficiency: 66 outdoor models compared
GE Appliances has 66 heat pump outdoor models certified with this refrigerant group, in 6,840 AHRI-certified combinations. They are also sold as GE. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes GE Appliances makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 66
- AHRI certifications
- 6,840
- Efficiency index
- 49%
- Typical model vs same-size, same-type peers (71 models)
- Meet CEE 2025
- 62.1%
- 41 models
How GE Appliances compares with comparable models
- GE Appliances
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index71 models scored | 49% | 22nd of 27 | — |
| COP at 5°F73 models scored | 42% | 24th of 27 | 1.89 |
| Capacity retention at 5°F73 models scored | 45% | 21st of 27 | 69% |
| HSPF279 models scored | 50% | 16th of 27 | 9.0 |
| SEER279 models scored | 46% | 18th of 27 | 18.0 |
| EER279 models scored | 50% | 15th of 27 | 11.7 |
| Heating capacity at 5°F73 models scored | 47% | 19th of 27 | 16,500 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 62.1% | 41 |
| CEE 2026 Tier 1 (Split ASHP) | 60.6% | 40 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 36.4% | 24 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 27.3% | 18 |
Sizes and duct types offered
- GE Appliances (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 9 | 42% | 31% | 40% | 42% |
| Ducted, 2 tons | 10 | 51% | 55% | 41% | 48% |
| Ducted, 2.5–3 tons | 9 | 53% | 61% | 43% | 44% |
| Ducted, 3.5–4.5 tons | 15 | 54% | 64% | 41% | 41% |
| Non-ducted, up to 1.5 tons | 24 | 53% | 33% | 67% | 56% |
| Non-ducted, 2 tons | 8 | 44% | 31% | 56% | 49% |
| Non-ducted, 2.5–3 tons | 4 | 35% | 25% | 52% | 25% |
| Non-ducted, 3.5–4.5 tons | 2 | 18% | 23% | 6% | 22% |
Every GE Appliances model in the market
- GE Appliances models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top GE Appliances models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ASH112URDE**GE Appliances · Endurewith ductless indoor unit ASYW12URDE | 1 ton12,000 Btu/h · Non-ducted | 103% | 1.90 | 12.5 | 14,900 | 27.5 | CEE 25CEE 26XcelES CC | 4 | 212409457 | Non-ducted, up to 1.5 tons | 79.5 |
| 2ASH109URDE**GE Appliances · Endurewith ductless indoor unit ASYW09URDE | 1 ton9,000 Btu/h · Non-ducted | 106% | 1.89 | 14.0 | 10,600 | 30.0 | CEE 25CEE 26XcelES CC | 4 | 212409456 | Non-ducted, up to 1.5 tons | 79.4 |
| 3NS17H48SA4-**AGEwith indoor coil D(A,C,E)48D44+TDR and furnace NF97D070M3B- | 4 tons45,500 Btu/h · Ducted | 71% | 2.96 | 8.7 | 34,200 | 14.6 | CEE 25CEE 26Xcel | 884 | 213884874 | Ducted, 3.5–4.5 tons | 78.1 |
| 4ASH118URDE**GE Appliances · Endurewith ductless indoor unit ASYW18URDE | 1.5 tons17,800 Btu/h · Non-ducted | 90% | 1.90 | 12.0 | 18,000 | 23.0 | CEE 25CEE 26XcelES CC | 4 | 212409458 | Non-ducted, up to 1.5 tons | 74.2 |
| 5ASH220NCDD**GE Appliances · Endure | 1.5 tons18,000 Btu/h · Non-ducted | 84% | 2.00 | 10.2 | 18,500 | 18.0 | CEE 25CEE 26XcelES CC | 3 | 210154187 | Non-ducted, up to 1.5 tons | 70.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ASH109URDE**GE Appliances · Endurewith ductless indoor unit ASYW09URDE | 1 ton9,000 Btu/h · Non-ducted | 106% | 1.89 | 14.0 | 30.0 | 16.0 | CEE 25CEE 26XcelES CC | 4 | 212409456 | Non-ducted, up to 1.5 tons | 88.8 | 79.4 | 98.1 | 79.4 |
| 2ASH112URDE**GE Appliances · Endurewith ductless indoor unit ASYW12URDE | 1 ton12,000 Btu/h · Non-ducted | 103% | 1.90 | 12.5 | 27.5 | 15.0 | CEE 25CEE 26XcelES CC | 4 | 212409457 | Non-ducted, up to 1.5 tons | 86.6 | 79.5 | 93.8 | 79.5 |
| 3NS22H36MA4-**AGEwith indoor coil D(A,C,E)36D44+TDR and furnace NF97D070M3B- | 3 tons34,000 Btu/h · Ducted | 67% | 2.78 | 9.4 | 20.0 | 12.0 | CEE 25CEE 26 | 423 | 213884682 | Ducted, 2.5–3 tons | 83.2 | 76.3 | 90.1 | Not a pick |
| 4NS22H24MA4-**AGE · NS22H SERIESwith ducted air handler NAM30V2TA4 | 2 tons24,000 Btu/h · Ducted | 70% | 2.32 | 9.5 | 21.0 | 13.5 | CEE 25CEE 26Xcel | 257 | 212396412 | Ducted, 2 tons | 82.7 | 67.5 | 98.0 | 67.5 |
| 5NS17H48SA4-**AGEwith indoor coil D(A,C,E)48D44+TDR and furnace NF80D110S5C- | 4 tons47,500 Btu/h · Ducted | 66% | 2.85 | 8.5 | 16.0 | 13.2 | CEE 25CEE 26Xcel | 884 | 213884846 | Ducted, 3.5–4.5 tons | 78.0 | 71.3 | 84.6 | 78.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | NS17H48SA4-**A | 2.99 | Ducted, 3.5–4.5 tons | 99% | 213884844 |
| Capacity retention at 5°F | ASH109URDE** | 106% | Non-ducted, up to 1.5 tons | 92% | 212409456 |
| HSPF2 | ASH109URDSE* | 14.0 | Non-ducted, up to 1.5 tons | 99% | 206842132 |
| SEER2 | ASH109URDSE* | 30.0 | Non-ducted, up to 1.5 tons | 100% | 206842132 |
| EER2 | NS17H18SA4-**A | 14.5 | Ducted, up to 1.5 tons | 100% | 214271283 |
| Heating capacity at 5°F | ASH220NCDD** | 18,500 Btu/h | Non-ducted, up to 1.5 tons | 94% | 210154187 |
GE Appliances size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 52.9(50 is the typical model of its size class)ASH220NCDD**4 of 9 models qualify · AHRI 210154190 | 61.2(50 is the typical model of its size class)NS17H18SA4-**Awith indoor coil D(A,C,E)24D34+TDR and furnace NF97D070M3B-7 of 9 models have all five ratings · AHRI 213884332 |
| Ducted, 2 tons | 67.5(50 is the typical model of its size class)NS22H24MA4-**Awith ducted air handler NAM30V2TA44 of 10 models qualify · AHRI 212396412 | 82.7(50 is the typical model of its size class)NS22H24MA4-**Awith ducted air handler NAM30V2TA49 of 10 models have all five ratings · AHRI 212396412 |
| Ducted, 2.5–3 tons | 62.0(50 is the typical model of its size class)ASH436NCDD**2 of 9 models qualify · AHRI 210154197 | 83.2(50 is the typical model of its size class)NS22H36MA4-**Awith indoor coil D(A,C,E)36D44+TDR and furnace NF97D070M3B-7 of 9 models have all five ratings · AHRI 213884682 |
| Ducted, 3.5–4.5 tons | 78.1(50 is the typical model of its size class)NS17H48SA4-**Awith indoor coil D(A,C,E)48D44+TDR and furnace NF97D070M3B-3 of 15 models qualify · AHRI 213884874 | 78.0(50 is the typical model of its size class)NS17H48SA4-**Awith indoor coil D(A,C,E)48D44+TDR and furnace NF80D110S5C-11 of 14 models have all five ratings · AHRI 213884846 |
| Ducted, 5 tons and up | No models in this size class | 67.6(50 is the typical model of its size class)NS17H60SA4-**Awith indoor coil NCUC60CT5D-**+TDR and furnace NF80U110T5C1 of 1 models have all five ratings · AHRI 217490085 |
| Non-ducted, up to 1.5 tons | 79.5(50 is the typical model of its size class)ASH112URDE**with ductless indoor unit ASYW12URDE12 of 24 models qualify · AHRI 212409457 | 88.8(50 is the typical model of its size class)ASH109URDE**with ductless indoor unit ASYW09URDE22 of 24 models have all five ratings · AHRI 212409456 |
| Non-ducted, 2 tons | 61.1(50 is the typical model of its size class)ASH324NCDD**5 of 8 models qualify · AHRI 210154192 | 59.8(50 is the typical model of its size class)ASH324JCDD**8 of 8 models have all five ratings · AHRI 207698999 |
| Non-ducted, 2.5–3 tons | 67.0(50 is the typical model of its size class)ASH436NCDD**3 of 4 models qualify · AHRI 210154196 | 48.7(50 is the typical model of its size class)ASH436NCDD**4 of 4 models have all five ratings · AHRI 210154196 |
| Non-ducted, 3.5–4.5 tons | 19.2(50 is the typical model of its size class)ASH4248UCDD**with ductless indoor unit USYL42UCDD1 of 2 models qualify · AHRI 211744614 | 18.3(50 is the typical model of its size class)ASH542JCDD**2 of 2 models have all five ratings · AHRI 210532846 |
Newest GE Appliances certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| NS17H48SA4-**AGE · NS17H Serieswith indoor coil NCUC60CT5D-**+TDR and furnace NF97X080V5C | 4 tons48,000 Btu/h · Ducted | 2.34 | 54% | 8.1 | 15.2 | CEE 25CEE 26Xcel | 884 | 217491486 |
| NS17H36SA4-**AGE · NS17H Serieswith indoor coil NCUC50CT5D-**+TDR and furnace NF97X080V5C | 3 tons36,000 Btu/h · Ducted | 2.10 | 52% | 7.8 | 15.8 | CEE 25CEE 26 | 1,320 | 217491485 |
| NS17H42SA4-**AGE · NS17H Serieswith indoor coil NCUC49CT5D-**+TDR and furnace NF97X080V4C | 3.5 tons42,000 Btu/h · Ducted | 2.06 | 51% | 7.8 | 15.2 | CEE 25CEE 26 | 668 | 217491480 |
| NS17H30SA4-**AGE · NS17H Serieswith indoor coil NCHC36CT5D-**+TDR and furnace NF97X080V4C | 2.5 tons29,000 Btu/h · Ducted | 2.20 | 51% | 8.3 | 15.6 | CEE 25CEE 26 | 1,115 | 217491474 |
| NS17H24SA4-**AGE · NS17H Serieswith indoor coil NCUC30BT5D-**+TDR and furnace NF97X060V3B | 2 tons23,000 Btu/h · Ducted | 2.02 | 49% | 7.8 | 16.2 | CEE 25CEE 26 | 522 | 217491467 |
Compare GE Appliances
GE Appliances includes these brand names as listed in AHRI: GE, GE Appliances. Standards are checked against published thresholds; program rules beyond ratings are not checked.