Skip to content

Genie Aire heat pump efficiency: 6 outdoor models compared

Genie Aire has 6 heat pump outdoor models certified with this refrigerant group, in 6 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Genie Aire makes. Genie Aire has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
6
AHRI certifications
6
Efficiency index
35%
Typical model vs same-size, same-type peers (6 models)
Meet CEE 2025
50%
3 models

How Genie Aire compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Genie Aire against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of Genie Aire’s own modelsGenie Aire is strongest on COP at 5°F (its typical model beats 52% of comparable models) and weakest on capacity retention at 5°F (22%).
  • Genie Aire
  • Middle half of its models
  • Other ranked manufacturers
Genie Ai…

Source: AHRI Directory, NEEP · as of

Average peer percentile of Genie Aire’s models
RatingBeats comparable modelsRankRaw median
Efficiency index6 models scored35%Not ranked—
COP at 5°F6 models scored52%Not ranked1.92
Capacity retention at 5°F6 models scored22%Not ranked62%
HSPF26 models scored34%Not ranked8.7
SEER26 models scored39%Not ranked20.2
EER26 models scored31%Not ranked10.6
Heating capacity at 5°F6 models scored27%Not ranked9,850 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Genie Aire’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • Genie Aire (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons438%45%39%45%
Non-ducted, 2 tons127%43%37%27%
Non-ducted, 2.5–3 tons135%87%14%24%

Every Genie Aire model in the market

Genie Aire’s 6 models with a known size and duct type, over the shape of the whole catalog.
Genie Aire models by size and ratingColoured: Genie Aire · grey shapes: all 11,475 models · lines: catalog medians by size
  • Genie Aire models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 6 genie aire models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top Genie Aire models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 1 Genie Aire cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1GA-09HP115V/OGenie Aire · GA serieswith ductless indoor unit GA-09HP115V/I1 ton9,000 Btu/h · Non-ducted70%2.169.17,00021.5CEE 25CEE 26XcelES CC1212674037Non-ducted, up to 1.5 tons56.7

All-around best

Top 5 Genie Aire models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1GA-09HP115V/OGenie Aire · GA serieswith ductless indoor unit GA-09HP115V/I1 ton9,000 Btu/h · Non-ducted70%2.169.121.512.5CEE 25CEE 26XcelES CC1212674037Non-ducted, up to 1.5 tons54.656.752.556.7
2GA-12HP230V/OGenie Airewith ductless indoor unit GA-12HP230V/I1 ton12,000 Btu/h · Non-ducted67%1.799.221.410.8CEE 25CEE 261212674039Non-ducted, up to 1.5 tons36.031.440.6Not a pick
3GA-18HP230V/OGenie Aire · GA serieswith ductless indoor unit GA-18HP230V/I1.5 tons18,000 Btu/h · Non-ducted62%2.078.719.511.0CEE 25CEE 261212674040Non-ducted, up to 1.5 tons35.939.931.8Not a pick
4GA-36HP230V/OGenie Airewith ductless indoor unit GA-36HP230V/I3 tons36,000 Btu/h · Non-ducted61%2.017.818.09.5None1212674042Non-ducted, 2.5–3 tons34.741.328.2Not a pick
5GA-24HP230V/OGenie Airewith ductless indoor unit GA-24HP230V/I2 tons24,000 Btu/h · Non-ducted62%1.838.618.59.5None1212674041Non-ducted, 2 tons27.231.622.7Not a pick

Best model on each rating

Genie Aire’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FGA-36HP230V/O2.01Non-ducted, 2.5–3 tons87%212674042
Capacity retention at 5°FGA-09HP115V/O70%Non-ducted, up to 1.5 tons39%212674037
HSPF2GA-12HP230V/O9.2Non-ducted, up to 1.5 tons50%212674039
SEER2GA-09HP115V/O21.5Non-ducted, up to 1.5 tons52%212674037
EER2GA-09HP115V/O12.5Non-ducted, up to 1.5 tons49%212674037
Heating capacity at 5°FGA-18HP230V/O11,700 Btu/hNon-ducted, up to 1.5 tons63%212674040

All 6 Genie Aire models in Explore

Genie Aire size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Genie Aire: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons56.7(50 is the typical model of its size class)GA-09HP115V/Owith ductless indoor unit GA-09HP115V/I1 of 4 models qualify · AHRI 21267403754.6(50 is the typical model of its size class)GA-09HP115V/Owith ductless indoor unit GA-09HP115V/I4 of 4 models have all five ratings · AHRI 212674037
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)27.2(50 is the typical model of its size class)GA-24HP230V/Owith ductless indoor unit GA-24HP230V/I1 of 1 models have all five ratings · AHRI 212674041
Non-ducted, 2.5–3 tonsNone on this board (0 of 1 models qualify)34.7(50 is the typical model of its size class)GA-36HP230V/Owith ductless indoor unit GA-36HP230V/I1 of 1 models have all five ratings · AHRI 212674042

All-around board, every manufacturer

Newest Genie Aire certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Genie Aire outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
GA-36HP230V/OGenie Airewith ductless indoor unit GA-36HP230V/I3 tons36,000 Btu/h · Non-ducted2.0161%7.818.0None1212674042
GA-24HP230V/OGenie Airewith ductless indoor unit GA-24HP230V/I2 tons24,000 Btu/h · Non-ducted1.8362%8.618.5None1212674041
GA-18HP230V/OGenie Aire · GA serieswith ductless indoor unit GA-18HP230V/I1.5 tons18,000 Btu/h · Non-ducted2.0762%8.719.5CEE 25CEE 261212674040
GA-12HP230V/OGenie Airewith ductless indoor unit GA-12HP230V/I1 ton12,000 Btu/h · Non-ducted1.7967%9.221.4CEE 25CEE 261212674039
GA-12HP115V/OGenie Airewith ductless indoor unit GA-12HP115V/I1 ton12,000 Btu/h · Non-ducted1.7853%8.720.8None1212674038

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Genie Aire

Manufacturers of a similar size, side by side.

Genie Aire includes these brand names as listed in AHRI: Genie Aire. Standards are checked against published thresholds; program rules beyond ratings are not checked.