Skip to content

Honeywell heat pump efficiency: 4 outdoor models compared

Honeywell has 4 heat pump outdoor models certified with this refrigerant group, in 14 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Honeywell makes. Honeywell has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
4
AHRI certifications
14
Efficiency index
55%
Typical model vs same-size, same-type peers (4 models)
Meet CEE 2025
100%
4 models

How Honeywell compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Honeywell against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of Honeywell’s own modelsHoneywell is strongest on SEER2 (its typical model beats 68% of comparable models) and weakest on EER2 (42%).
  • Honeywell
  • Middle half of its models
  • Other ranked manufacturers
Honeywell

Source: AHRI Directory, NEEP · as of

Average peer percentile of Honeywell’s models
RatingBeats comparable modelsRankRaw median
Efficiency index4 models scored55%Not ranked—
COP at 5°F4 models scored47%Not ranked1.90
Capacity retention at 5°F4 models scored51%Not ranked70%
HSPF24 models scored66%Not ranked8.8
SEER24 models scored68%Not ranked16.5
EER24 models scored42%Not ranked10.7
Heating capacity at 5°F4 models scored60%Not ranked30,200 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Honeywell’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • Honeywell (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, 2 tons155%67%58%65%
Ducted, 2.5–3 tons147%29%69%56%
Ducted, 3.5–4.5 tons259%45%69%74%

Every Honeywell model in the market

Honeywell’s 4 models with a known size and duct type, over the shape of the whole catalog.
Honeywell models by size and ratingColoured: Honeywell · grey shapes: all 11,475 models · lines: catalog medians by size
  • Honeywell models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 4 honeywell models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top Honeywell models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 3 Honeywell cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1HSH17S-60AAAHoneywellwith ducted air handler HVTAN-48SA4 tons48,000 Btu/h · Ducted81%1.809.039,00017.0CEE 25CEE 26Xcel2208480448Ducted, 3.5–4.5 tons58.1
2HOH16S-60AAHoneywell · SVSwith ducted air handler HVTAN-60A4.5 tons54,000 Btu/h · Ducted70%1.908.538,00015.2CEE 25CEE 26Xcel6207698172Ducted, 3.5–4.5 tons56.9
3HSH17S-36AAAHoneywellwith ducted air handler HVTAN-36SA3 tons34,000 Btu/h · Ducted80%1.809.028,00016.0CEE 25CEE 26Xcel2208480447Ducted, 2.5–3 tons55.3

All-around best

Top 4 Honeywell models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1HSH17S-60AAAHoneywellwith ducted air handler HVTAN-48SA4 tons48,000 Btu/h · Ducted81%1.809.017.011.0CEE 25CEE 26Xcel2208480448Ducted, 3.5–4.5 tons63.358.168.458.1
2HSH17S-36AAAHoneywellwith ducted air handler HVTAN-24SA2 tons24,000 Btu/h · Ducted92%1.809.017.012.0CEE 25CEE 26Xcel2208480450Ducted, 2.5–3 tons61.053.768.455.3
3HOH16S-60AAHoneywell · SVSwith ducted air handler HVTAN-36A3 tons35,000 Btu/h · Ducted53%2.008.517.011.7CEE 25CEE 26Xcel6207698174Ducted, 3.5–4.5 tons60.048.571.556.9
4HOH16S-36AAHoneywell · SVSwith ducted air handler HVTAN-24A2 tons23,600 Btu/h · Ducted51%2.108.517.011.7CEE 25CEE 264207698173Ducted, 2 tons54.948.261.6Not a pick

Best model on each rating

Honeywell’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FHOH16S-36AA2.10Ducted, 2 tons67%207698173
Capacity retention at 5°FHSH17S-60AAA81%Ducted, 3.5–4.5 tons73%208480448
HSPF2HSH17S-60AAA9.0Ducted, 3.5–4.5 tons73%208480448
SEER2HSH17S-60AAA17.0Ducted, 3.5–4.5 tons77%208480448
EER2HOH16S-60AA11.7Ducted, 2.5–3 tons67%207698174
Heating capacity at 5°FHSH17S-60AAA41,000 Btu/hDucted, 3.5–4.5 tons74%208480449

All 4 Honeywell models in Explore

Honeywell size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Honeywell: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, 2 tonsNone on this board (0 of 1 models qualify)61.0(50 is the typical model of its size class)HSH17S-36AAAwith ducted air handler HVTAN-24SA2 of 2 models have all five ratings · AHRI 208480450
Ducted, 2.5–3 tons55.3(50 is the typical model of its size class)HSH17S-36AAAwith ducted air handler HVTAN-36SA1 of 1 models qualify · AHRI 20848044760.0(50 is the typical model of its size class)HOH16S-60AAwith ducted air handler HVTAN-36A1 of 1 models have all five ratings · AHRI 207698174
Ducted, 3.5–4.5 tons58.1(50 is the typical model of its size class)HSH17S-60AAAwith ducted air handler HVTAN-48SA2 of 2 models qualify · AHRI 20848044863.3(50 is the typical model of its size class)HSH17S-60AAAwith ducted air handler HVTAN-48SA1 of 1 models have all five ratings · AHRI 208480448

All-around board, every manufacturer

Newest Honeywell certifications

By AHRI reference number; AHRI issues references in increasing order.
The 4 most recently certified Honeywell outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
HOH16S-60AAHoneywellwith ducted air handler GNC4860DPT4.5 tons51,000 Btu/h · Ducted1.9065%8.114.3CEE 25CEE 26Xcel6209938293
HOH16S-36AAHoneywellwith ducted air handler GNC3036BPT2.5 tons30,000 Btu/h · Ducted1.9060%8.114.3CEE 25CEE 264209938290
HSH17S-36AAAHoneywellwith ducted air handler HVTAN-24SA2 tons24,000 Btu/h · Ducted1.8092%9.017.0CEE 25CEE 26Xcel2208480450
HSH17S-60AAAHoneywellwith ducted air handler HVTAN-60SA4.5 tons54,000 Btu/h · Ducted1.8076%9.016.0CEE 25CEE 26Xcel2208480449

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for Honeywell in this group.

Compare Honeywell

Manufacturers of a similar size, side by side.

Honeywell includes these brand names as listed in AHRI: Honeywell. Standards are checked against published thresholds; program rules beyond ratings are not checked.