Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
IAIR heat pump efficiency: 35 outdoor models compared
IAIR has 35 heat pump outdoor models certified with this refrigerant group, in 103 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes IAIR makes. IAIR has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 35
- AHRI certifications
- 103
- Efficiency index
- 18%
- Typical model vs same-size, same-type peers (12 models)
- Meet CEE 2025
- 0%
- 0 models
How IAIR compares with comparable models
- IAIR
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index12 models scored | 18% | Not ranked | — |
| COP at 5°F12 models scored | 2% | Not ranked | 1.40 |
| Capacity retention at 5°F12 models scored | 4% | Not ranked | 36% |
| HSPF235 models scored | 19% | Not ranked | 7.5 |
| SEER235 models scored | 15% | Not ranked | 14.3 |
| EER235 models scored | 60% | Not ranked | 11.5 |
| Heating capacity at 5°F12 models scored | 4% | Not ranked | 13,300 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0% | 0 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- IAIR (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 3 | — | — | 12% | 10% |
| Ducted, 2 tons | 5 | 12% | 1% | 16% | 11% |
| Ducted, 2.5–3 tons | 10 | 16% | 2% | 17% | 11% |
| Ducted, 3.5–4.5 tons | 15 | 21% | 1% | 24% | 21% |
| Ducted, 5 tons and up | 2 | 19% | 4% | 9% | 12% |
Every IAIR model in the market
- IAIR models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top IAIR models
Cold-climate picks
No IAIR model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1APH3048E100AIAIRAlso listed as IPH3048E100A | 4 tons46,500 Btu/h · Ducted | 37% | 1.40 | 6.7 | 13.4 | 11.4 | None | 1 | 212255588 | Ducted, 3.5–4.5 tons | 21.5 | 4.6 | 38.3 | Not a pick |
| 2APH3042E100AIAIRAlso listed as IPH3042E100A | 3.5 tons40,500 Btu/h · Ducted | 37% | 1.40 | 6.7 | 13.4 | 11.2 | None | 1 | 212255586 | Ducted, 3.5–4.5 tons | 20.4 | 4.2 | 36.5 | Not a pick |
| 3APH3060E100AIAIRAlso listed as IPH3060E100A | 5 tons57,000 Btu/h · Ducted | 38% | 1.40 | 6.7 | 13.4 | 11.0 | None | 1 | 212255589 | Ducted, 5 tons and up | 19.3 | 5.9 | 32.7 | Not a pick |
| 4APH3036E100AIAIRAlso listed as IPH3036E100A | 3 tons34,200 Btu/h · Ducted | 34% | 1.40 | 6.7 | 13.4 | 11.2 | None | 1 | 212255584 | Ducted, 2.5–3 tons | 17.3 | 3.6 | 31.0 | Not a pick |
| 5APH3030E100AIAIRAlso listed as IPH3030E100A | 2.5 tons28,200 Btu/h · Ducted | 35% | 1.40 | 6.7 | 13.4 | 11.0 | None | 1 | 212255583 | Ducted, 2.5–3 tons | 15.2 | 4.1 | 26.2 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | APH3060E100AAlso listed as IPH3060E100A | 1.40 | Ducted, 5 tons and up | 4% | 212255589 |
| Capacity retention at 5°F | APH3060E100AAlso listed as IPH3060E100A | 38% | Ducted, 5 tons and up | 5% | 212255589 |
| HSPF2 | AHP5042E1000AAlso listed as IHP5042E1000A | 7.8 | Ducted, 3.5–4.5 tons | 39% | 211290018 |
| SEER2 | AHP5042E1000AAlso listed as IHP5042E1000A | 15.2 | Ducted, 3.5–4.5 tons | 40% | 211290018 |
| EER2 | AHP5042E1000AAlso listed as IHP5042E1000A | 12.0 | Ducted, 3.5–4.5 tons | 82% | 211290018 |
| Heating capacity at 5°F | APH3060E100AAlso listed as IPH3060E100A | 21,600 Btu/h | Ducted, 5 tons and up | 11% | 212255589 |
IAIR size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 3 models qualify) | None on this board (0 of 3 models have all five ratings) |
| Ducted, 2 tons | None on this board (0 of 5 models qualify) | 12.4(50 is the typical model of its size class)APH3024E100AAlso listed as IPH3024E100A2 of 5 models have all five ratings · AHRI 211289991 |
| Ducted, 2.5–3 tons | None on this board (0 of 10 models qualify) | 17.3(50 is the typical model of its size class)APH3036E100AAlso listed as IPH3036E100A4 of 10 models have all five ratings · AHRI 212255584 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 15 models qualify) | 21.5(50 is the typical model of its size class)APH3048E100AAlso listed as IPH3048E100A4 of 15 models have all five ratings · AHRI 212255588 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 19.3(50 is the typical model of its size class)APH3060E100AAlso listed as IPH3060E100A2 of 2 models have all five ratings · AHRI 212255589 |
Newest IAIR certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| IHP5060E1000AIAIRwith ducted air handler I4AH5E60E1B00T | 4.5 tons54,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 2 | 214783948 |
| IHP5048E1000AIAIRwith ducted air handler I4AH5E60E1B00T | 4 tons45,000 Btu/h · Ducted | — | — | 7.8 | 15.2 | None | 4 | 214783947 |
| IHP5042E1000AIAIRwith ducted air handler I4AH5E60E1B00T | 3.5 tons41,500 Btu/h · Ducted | — | — | 7.8 | 15.2 | None | 6 | 214783945 |
| IHP5036E1000AIAIRwith ducted air handler I4AH5E36E1B00T | 3 tons34,200 Btu/h · Ducted | — | — | 7.8 | 15.2 | None | 10 | 214783942 |
| IHP5030E1000AIAIRwith ducted air handler I4AH5E36E1B00T | 2.5 tons28,200 Btu/h · Ducted | — | — | 7.8 | 15.2 | None | 11 | 214783939 |
Compare IAIR