Skip to content

KeplerX heat pump efficiency: 8 outdoor models compared

KeplerX has 8 heat pump outdoor models certified with this refrigerant group, in 12 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes KeplerX makes. KeplerX has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
8
AHRI certifications
12
Efficiency index
53%
Typical model vs same-size, same-type peers (1 model)
Meet CEE 2025
0%
0 models

How KeplerX compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
KeplerX against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of KeplerX’s own modelsKeplerX is strongest on heating capacity at 5°F (its typical model beats 95% of comparable models) and weakest on SEER2 (22%).
  • KeplerX
  • Middle half of its models
  • Other ranked manufacturers
KeplerX

Source: AHRI Directory, NEEP · as of

Average peer percentile of KeplerX’s models
RatingBeats comparable modelsRankRaw median
Efficiency index1 model scored53%Not ranked—
COP at 5°F1 model scored49%Not ranked1.91
Capacity retention at 5°F1 model scored78%Not ranked82%
HSPF28 models scored33%Not ranked7.5
SEER28 models scored22%Not ranked14.3
EER28 models scored54%Not ranked11.5
Heating capacity at 5°F1 model scored95%Not ranked48,500 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
KeplerX’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • KeplerX (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons1——12%10%
Ducted, 2 tons1——22%14%
Ducted, 2.5–3 tons2——24%15%
Ducted, 3.5–4.5 tons453%49%45%30%

Every KeplerX model in the market

KeplerX’s 8 models with a known size and duct type, over the shape of the whole catalog.
KeplerX models by size and ratingColoured: KeplerX · grey shapes: all 11,475 models · lines: catalog medians by size
  • KeplerX models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 8 keplerx models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top KeplerX models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 1 KeplerX cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1K18HVH60WD2UKeplerXwith ducted air handler K18HVH60WD2H4.5 tons55,000 Btu/h · Ducted82%1.919.448,50015.3None1214655291Ducted, 3.5–4.5 tons71.3

All-around best

Top 1 KeplerX models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1K18HVH60WD2UKeplerXwith ducted air handler K18HVH60WD2H4.5 tons55,000 Btu/h · Ducted82%1.919.415.38.8None1214655291Ducted, 3.5–4.5 tons53.371.335.371.3

Best model on each rating

KeplerX’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FK18HVH60WD2U1.91Ducted, 3.5–4.5 tons49%214655291
Capacity retention at 5°FK18HVH60WD2U82%Ducted, 3.5–4.5 tons75%214655291
HSPF2K18HVH60WD2U9.4Ducted, 3.5–4.5 tons87%214655291
SEER2K18HVH60WD2U15.3Ducted, 3.5–4.5 tons50%214655291
EER2K15HVH42W2V11.5Ducted, 3.5–4.5 tons68%212386833
Heating capacity at 5°FK18HVH60WD2U48,500 Btu/hDucted, 3.5–4.5 tons95%214655291

All 8 KeplerX models in Explore

KeplerX size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
KeplerX: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models have all five ratings)
Ducted, 2 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models have all five ratings)
Ducted, 2.5–3 tonsNone on this board (0 of 2 models qualify)None on this board (0 of 2 models have all five ratings)
Ducted, 3.5–4.5 tons71.3(50 is the typical model of its size class)K18HVH60WD2Uwith ducted air handler K18HVH60WD2H1 of 4 models qualify · AHRI 21465529153.3(50 is the typical model of its size class)K18HVH60WD2Uwith ducted air handler K18HVH60WD2H1 of 4 models have all five ratings · AHRI 214655291

All-around board, every manufacturer

Newest KeplerX certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified KeplerX outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
K18HVH60WD2UKeplerXwith ducted air handler K18HVH60WD2H4.5 tons55,000 Btu/h · Ducted1.9182%9.415.3None1214655291
K15HVH36W2VKeplerXwith ducted air handler K15HVC36W2F3 tons33,000 Btu/h · Ducted——7.514.3None2212386839
K15HVH30W2VKeplerXwith ducted air handler K15HVC30W2F2.5 tons28,000 Btu/h · Ducted——7.514.3None2212386838
K15HVH24W2VKeplerXwith ducted air handler K15HVC24W2F2 tons22,000 Btu/h · Ducted——7.514.3None2212386837
K15HVH18W2VKeplerXwith ducted air handler K15HVC18W2F1.5 tons17,500 Btu/h · Ducted——7.514.3None2212386836

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare KeplerX

Manufacturers of a similar size, side by side.