Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
KERR heat pump efficiency: 24 outdoor models compared
KERR has 24 heat pump outdoor models certified with this refrigerant group, in 90 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes KERR makes. KERR has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 24
- AHRI certifications
- 90
- Efficiency index
- 66%
- Typical model vs same-size, same-type peers (35 models)
- Meet CEE 2025
- 83.3%
- 20 models
How KERR compares with comparable models
- KERR
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index35 models scored | 66% | Not ranked | — |
| COP at 5°F35 models scored | 49% | Not ranked | 1.95 |
| Capacity retention at 5°F35 models scored | 78% | Not ranked | 91% |
| HSPF236 models scored | 76% | Not ranked | 10.0 |
| SEER236 models scored | 68% | Not ranked | 20.0 |
| EER236 models scored | 58% | Not ranked | 11.9 |
| Heating capacity at 5°F35 models scored | 75% | Not ranked | 25,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 83.3% | 20 |
| CEE 2026 Tier 1 (Split ASHP) | 83.3% | 20 |
| CEE Advanced Tier (Split ASHP) | 8.3% | 2 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 79.2% | 19 |
| DOE Cold Climate Heat Pump Challenge | 8.3% | 2 |
| ENERGY STAR Cold Climate | 87.5% | 21 |
Sizes and duct types offered
- KERR (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 6 | 60% | 33% | 67% | 65% |
| Ducted, 2 tons | 3 | 71% | 46% | 88% | 79% |
| Ducted, 2.5–3 tons | 5 | 67% | 44% | 87% | 67% |
| Ducted, 3.5–4.5 tons | 4 | 63% | 43% | 82% | 76% |
| Non-ducted, up to 1.5 tons | 7 | 68% | 54% | 78% | 61% |
| Non-ducted, 2 tons | 3 | 79% | 86% | 94% | 74% |
| Non-ducted, 2.5–3 tons | 6 | 64% | 57% | 60% | 58% |
| Non-ducted, 3.5–4.5 tons | 2 | 65% | 39% | 58% | 82% |
Every KERR model in the market
- KERR models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top KERR models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1A-KMH36QV-1AKerr · A-KMH Series | 3 tons36,000 Btu/h · Non-ducted | 103% | 2.00 | 10.9 | 37,000 | 22.4 | CEE 25CEE 26XcelES CC | 3 | 217169740 | Non-ducted, 2.5–3 tons | 90.9 |
| 2A-KMH06SV-1KERR · A serieswith ductless indoor unit B-KMH06SV-1 | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 7,500 | 26.5 | CEE 25CEE 26XcelES CC | 1 | 207657393 | Non-ducted, up to 1.5 tons | 89.3 |
| 3A-KMH24SV-1KERR · A serieswith ductless indoor unit C-VMH24CV-1 | 2 tons24,000 Btu/h · Non-ducted | 103% | 2.00 | 11.5 | 25,800 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 207657400 | Non-ducted, 2 tons | 86.1 |
| 4A-KMH24SU-1AKERR · A serieswith ductless indoor unit B-KMH24UU-1 | 2 tons24,000 Btu/h · Non-ducted | 100% | 2.10 | 11.0 | 25,000 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 206347323 | Non-ducted, 2 tons | 85.4 |
| 5A-KMH24SU-1KERR · A serieswith ductless indoor unit B-KMH24SV-1 | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 25,000 | 21.5 | CEE 25CEE 26XcelES CC | 2 | 208141201 | Non-ducted, 2 tons | 84.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1A-KMH06SV-1KERR · A serieswith ductless indoor unit B-KMH06SV-1 | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 26.5 | 15.8 | CEE 25CEE 26XcelES CC | 1 | 207657393 | Non-ducted, up to 1.5 tons | 92.0 | 89.3 | 94.7 | 89.3 |
| 2A-KMH09SV-1KERR · A serieswith ductless indoor unit B-KMH09SV-1 | 1 ton9,000 Btu/h · Non-ducted | 88% | 1.97 | 11.5 | 28.1 | 16.2 | CEE 25CEE 26XcelES CC | 4 | 207657394 | Non-ducted, up to 1.5 tons | 87.0 | 76.2 | 97.9 | 76.2 |
| 3A-KMH36QV-1AKerr · A-KMH Series | 3 tons36,000 Btu/h · Non-ducted | 103% | 2.00 | 10.9 | 22.4 | 12.5 | CEE 25CEE 26XcelES CC | 3 | 217169740 | Non-ducted, 2.5–3 tons | 86.4 | 90.9 | 81.8 | 90.9 |
| 4A-KMH09SV-1KERR · A serieswith ducted air handler B-KMH09DU-1 | 1 ton9,000 Btu/h · Ducted | 108% | 1.90 | 12.0 | 20.2 | 13.2 | CEE 25CEE 26XcelES CC | 4 | 210568255 | Ducted, up to 1.5 tons | 85.2 | 74.9 | 95.5 | 74.9 |
| 5A-KMH24SV-1KERR · A serieswith ductless indoor unit B-KMH24SV-1Also listed as A-KMH24SU-1 | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 21.5 | 13.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 207657397 | Non-ducted, 2 tons | 84.3 | 84.5 | 84.1 | 86.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | A-KMH24SV-1Also listed as A-KMH24SU-1 | 2.21 | Non-ducted, 2 tons | 91% | 207657397 |
| Capacity retention at 5°F | A-KCD36SA-1 | 112% | Ducted, 2.5–3 tons | 98% | 213255488 |
| HSPF2 | A-KMH06SV-1 | 13.6 | Non-ducted, up to 1.5 tons | 98% | 207657393 |
| SEER2 | A-KMH48PV-1 | 20.9 | Ducted, 3.5–4.5 tons | 99% | 207657607 |
| EER2 | A-KMH09SV-1 | 16.2 | Non-ducted, up to 1.5 tons | 98% | 207657394 |
| Heating capacity at 5°F | A-KCD36SA-1 | 42,000 Btu/h | Ducted, 2.5–3 tons | 99% | 213255488 |
KERR size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 74.9(50 is the typical model of its size class)A-KMH09SV-1with ducted air handler B-KMH09DU-16 of 6 models qualify · AHRI 210568255 | 85.2(50 is the typical model of its size class)A-KMH09SV-1with ducted air handler B-KMH09DU-16 of 6 models have all five ratings · AHRI 210568255 |
| Ducted, 2 tons | 79.4(50 is the typical model of its size class)A-KMH24SU-1Awith ducted air handler B-KMH24DU-1Also listed as A-KMH24SV-13 of 3 models qualify · AHRI 206347321 | 80.1(50 is the typical model of its size class)A-KMH24SU-1Awith ducted air handler B-KMH24DU-1Also listed as A-KMH24SV-13 of 3 models have all five ratings · AHRI 206347321 |
| Ducted, 2.5–3 tons | 79.9(50 is the typical model of its size class)A-KMH36QV-1A5 of 5 models qualify · AHRI 217169741 | 83.7(50 is the typical model of its size class)A-KMH36QV-1A5 of 5 models have all five ratings · AHRI 217169741 |
| Ducted, 3.5–4.5 tons | 74.9(50 is the typical model of its size class)A-KMH48PV-14 of 4 models qualify · AHRI 207657607 | 82.0(50 is the typical model of its size class)A-KMH48PV-14 of 4 models have all five ratings · AHRI 207657607 |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class)A-KMH06SV-1with ductless indoor unit B-KMH06SV-17 of 7 models qualify · AHRI 207657393 | 92.0(50 is the typical model of its size class)A-KMH06SV-1with ductless indoor unit B-KMH06SV-17 of 7 models have all five ratings · AHRI 207657393 |
| Non-ducted, 2 tons | 86.1(50 is the typical model of its size class)A-KMH24SV-1with ductless indoor unit C-VMH24CV-13 of 3 models qualify · AHRI 207657400 | 84.3(50 is the typical model of its size class)A-KMH24SV-1with ductless indoor unit B-KMH24SV-1Also listed as A-KMH24SU-13 of 3 models have all five ratings · AHRI 207657397 |
| Non-ducted, 2.5–3 tons | 90.9(50 is the typical model of its size class)A-KMH36QV-1A3 of 6 models qualify · AHRI 217169740 | 86.4(50 is the typical model of its size class)A-KMH36QV-1A5 of 6 models have all five ratings · AHRI 217169740 |
| Non-ducted, 3.5–4.5 tons | 76.2(50 is the typical model of its size class)A-KMH48PV-12 of 2 models qualify · AHRI 207657606 | 77.9(50 is the typical model of its size class)A-KMH48PV-12 of 2 models have all five ratings · AHRI 207657606 |
Newest KERR certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| A-KCD36SA-1Kerr · A Serieswith ducted air handler MCD30/36B1A | 3 tons35,000 Btu/h · Ducted | 1.85 | 83% | 8.6 | 15.5 | CEE 25CEE 26XcelES CC | 6 | 217542270 |
| A-KCD30SA-1Kerr · A Serieswith ducted air handler MCD30/36B1A | 2.5 tons29,000 Btu/h · Ducted | 1.80 | 73% | 8.5 | 15.2 | CEE 25CEE 26XcelES CC | 12 | 217542269 |
| A-KMH36QV-1AKerr · A-KMH Series | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.95 | 101% | 10.5 | 20.9 | CEE 25CEE 26XcelES CC | 3 | 217169742 |
| A-KMH55PV-1KERR · A-series | 4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.77 | 85% | 9.4 | 20.4 | CEE 25CEE 26XcelES CC | 3 | 214232460 |
| A-KMH12SV-1KERR · A-serieswith ductless indoor unit B-KMH12FV-1 | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.99 | 99% | 10.7 | 24.2 | CEE 25CEE 26XcelES CC | 6 | 213916259 |
Compare KERR
KERR includes these brand names as listed in AHRI: KERR. Standards are checked against published thresholds; program rules beyond ratings are not checked.