LBG Products heat pump efficiency: 60 outdoor models compared
LBG Products has 60 heat pump outdoor models certified with this refrigerant group, in 128 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes LBG Products makes. LBG Products has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 60
- AHRI certifications
- 128
- Efficiency index
- 53%
- Typical model vs same-size, same-type peers (85 models)
- Meet CEE 2025
- 66.7%
- 40 models
How LBG Products compares with comparable models
- LBG Products
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index85 models scored | 53% | Not ranked | — |
| COP at 5°F85 models scored | 46% | Not ranked | 1.90 |
| Capacity retention at 5°F85 models scored | 60% | Not ranked | 74% |
| HSPF285 models scored | 65% | Not ranked | 9.4 |
| SEER285 models scored | 55% | Not ranked | 18.8 |
| EER285 models scored | 43% | Not ranked | 10.9 |
| Heating capacity at 5°F85 models scored | 58% | Not ranked | 19,400 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 66.7% | 40 |
| CEE 2026 Tier 1 (Split ASHP) | 63.3% | 38 |
| CEE Advanced Tier (Split ASHP) | 1.7% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 58.3% | 35 |
| DOE Cold Climate Heat Pump Challenge | 1.7% | 1 |
| ENERGY STAR Cold Climate | 50% | 30 |
Sizes and duct types offered
- LBG Products (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 11 | 58% | 45% | 66% | 64% |
| Ducted, 2 tons | 6 | 59% | 45% | 76% | 59% |
| Ducted, 2.5–3 tons | 11 | 54% | 41% | 76% | 62% |
| Ducted, 3.5–4.5 tons | 9 | 53% | 41% | 81% | 59% |
| Ducted, 5 tons and up | 2 | 51% | 49% | 77% | 61% |
| Non-ducted, up to 1.5 tons | 23 | 55% | 54% | 61% | 55% |
| Non-ducted, 2 tons | 8 | 47% | 38% | 54% | 46% |
| Non-ducted, 2.5–3 tons | 9 | 49% | 41% | 56% | 50% |
| Non-ducted, 3.5–4.5 tons | 6 | 44% | 51% | 52% | 35% |
Every LBG Products model in the market
- LBG Products models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top LBG Products models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1LUUHB48DOLBG Products · LUH serieswith ducted air handler LUHB48DFI | 4 tons48,000 Btu/h · Ducted | 96% | 2.02 | 10.3 | 46,000 | 14.3 | None | 3 | 208130842 | Ducted, 3.5–4.5 tons | 88.9 |
| 2LBHB24DVWOLBG Products · LBH serieswith ductless indoor unit LMHB24DZDI | 2 tons24,000 Btu/h · Non-ducted | 102% | 2.10 | 11.0 | 25,000 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 208130845 | Non-ducted, 2 tons | 87.1 |
| 3LBHB09DUWOLBG Products · LBH serieswith ductless indoor unit LBHB09DUWI | 1 ton9,000 Btu/h · Non-ducted | 86% | 2.22 | 11.6 | 8,564 | 24.0 | CEE 25CEE 26XcelES CC | 3 | 208130803 | Non-ducted, up to 1.5 tons | 86.0 |
| 4LUUHB36DOLBG Products · LUH serieswith ducted air handler LUHB36DFI | 3 tons36,000 Btu/h · Ducted | 90% | 1.98 | 11.0 | 36,000 | 16.5 | ES CC | 3 | 208130841 | Ducted, 2.5–3 tons | 83.4 |
| 5LBHB24DUWOLBG Products · LBH serieswith ducted air handler LMHB24DFI | 2 tons23,000 Btu/h · Ducted | 81% | 2.30 | 11.2 | 20,000 | 19.0 | CEE 25CEE 26XcelES CC | 4 | 208130816 | Ducted, 2 tons | 82.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1LBHB09DYWOLBG Products · LBH serieswith ductless indoor unit LBHB09DYWI | 1 ton9,000 Btu/h · Non-ducted | 113% | 1.86 | 14.0 | 29.0 | 16.5 | CEE 25CEE 26XcelES CC | 1 | 207629153 | Non-ducted, up to 1.5 tons | 88.8 | 78.6 | 99.0 | 78.6 |
| 2LBHB09DUWOLBG Products · LBH serieswith ductless indoor unit LBHB09DUWI | 1 ton9,000 Btu/h · Non-ducted | 86% | 2.22 | 11.6 | 24.0 | 14.7 | CEE 25CEE 26XcelES CC | 3 | 208130803 | Non-ducted, up to 1.5 tons | 86.7 | 86.0 | 87.5 | 86.0 |
| 3LBHB12DYWOLBG Products · LBH serieswith ductless indoor unit LBHB12DYWI | 1 ton12,000 Btu/h · Non-ducted | 113% | 1.86 | 14.5 | 27.5 | 14.3 | CEE 25CEE 26XcelES CC | 1 | 207629154 | Non-ducted, up to 1.5 tons | 85.6 | 78.7 | 92.6 | 78.7 |
| 4LBHB09DVWOLBG Products · LBH serieswith ducted air handler LMHB09DFI | 1 ton9,000 Btu/h · Ducted | 108% | 1.90 | 12.0 | 20.2 | 13.2 | CEE 25CEE 26XcelES CC | 3 | 208130837 | Ducted, up to 1.5 tons | 85.2 | 74.9 | 95.5 | 74.9 |
| 5LBHB24DUWOLBG Products · LBH serieswith ducted air handler LMHB24DFI | 2 tons23,000 Btu/h · Ducted | 81% | 2.30 | 11.2 | 19.0 | 12.5 | CEE 25CEE 26XcelES CC | 4 | 208130816 | Ducted, 2 tons | 84.9 | 82.4 | 87.4 | 82.4 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | LBHB18DUWO | 2.35 | Non-ducted, up to 1.5 tons | 94% | 208130805 |
| Capacity retention at 5°F | LMUH24DWO | 115% | Non-ducted, 2 tons | 98% | 206726756 |
| HSPF2 | LBHB12DYWO | 14.5 | Non-ducted, up to 1.5 tons | 100% | 207629154 |
| SEER2 | LBHB09DYWO | 29.0 | Non-ducted, up to 1.5 tons | 99% | 207629153 |
| EER2 | LBHB09DYWO | 16.5 | Non-ducted, up to 1.5 tons | 99% | 207629153 |
| Heating capacity at 5°F | LMUH18DWO | 21,800 Btu/h | Non-ducted, up to 1.5 tons | 99% | 206726754 |
LBG Products size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 74.9(50 is the typical model of its size class)LBHB09DVWOwith ducted air handler LMHB09DFI9 of 11 models qualify · AHRI 208130837 | 85.2(50 is the typical model of its size class)LBHB09DVWOwith ducted air handler LMHB09DFI11 of 11 models have all five ratings · AHRI 208130837 |
| Ducted, 2 tons | 82.4(50 is the typical model of its size class)LBHB24DUWOwith ducted air handler LMHB24DFI5 of 5 models qualify · AHRI 208130816 | 84.9(50 is the typical model of its size class)LBHB24DUWOwith ducted air handler LMHB24DFI6 of 6 models have all five ratings · AHRI 208130816 |
| Ducted, 2.5–3 tons | 83.4(50 is the typical model of its size class)LUUHB36DOwith ducted air handler LUHB36DFI7 of 12 models qualify · AHRI 208130841 | 75.4(50 is the typical model of its size class)LMHB27DO11 of 11 models have all five ratings · AHRI 207641307 |
| Ducted, 3.5–4.5 tons | 88.9(50 is the typical model of its size class)LUUHB48DOwith ducted air handler LUHB48DFI6 of 9 models qualify · AHRI 208130842 | 81.2(50 is the typical model of its size class)LMUHB48DO9 of 9 models have all five ratings · AHRI 207641326 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 57.1(50 is the typical model of its size class)LUHB60DOwith ducted air handler LUHB60DFI2 of 2 models have all five ratings · AHRI 208130819 |
| Non-ducted, up to 1.5 tons | 86.0(50 is the typical model of its size class)LBHB09DUWOwith ductless indoor unit LBHB09DUWI14 of 23 models qualify · AHRI 208130803 | 88.8(50 is the typical model of its size class)LBHB09DYWOwith ductless indoor unit LBHB09DYWI23 of 23 models have all five ratings · AHRI 207629153 |
| Non-ducted, 2 tons | 87.1(50 is the typical model of its size class)LBHB24DVWOwith ductless indoor unit LMHB24DZDI5 of 8 models qualify · AHRI 208130845 | 76.1(50 is the typical model of its size class)LBHB18DYWOwith ductless indoor unit LBHB18DYWI8 of 8 models have all five ratings · AHRI 207629155 |
| Non-ducted, 2.5–3 tons | 76.4(50 is the typical model of its size class)LMUHB36DO5 of 9 models qualify · AHRI 207641322 | 72.3(50 is the typical model of its size class)LMUHB36DO9 of 9 models have all five ratings · AHRI 207641322 |
| Non-ducted, 3.5–4.5 tons | 81.3(50 is the typical model of its size class)LUUHB48DOwith ductless indoor unit LUHB48DSI5 of 6 models qualify · AHRI 208130836 | 70.9(50 is the typical model of its size class)LMUHB48DO6 of 6 models have all five ratings · AHRI 207641325 |
Newest LBG Products certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| LBHB24DROLBG Productswith ductless indoor unit LBHB24DRI | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 63% | 8.0 | 16.7 | None | 1 | 213614238 |
| LBHB18DROLBG Productswith ductless indoor unit LBHB18DRI | 1.5 tons17,000 Btu/h · Non-ducted | 1.84 | 56% | 8.7 | 18.3 | None | 1 | 213614237 |
| LBHB12DROLBG Productswith ductless indoor unit LBHB12DRI | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 59% | 8.8 | 17.6 | None | 1 | 213614236 |
| LBHB09DROLBG Products · LBH serieswith ductless indoor unit LBHB09DRI | 1 ton9,000 Btu/h · Non-ducted | 2.10 | 71% | 8.8 | 18.5 | CEE 25CEE 26XcelES CC | 1 | 213614235 |
| LBHB12AROLBG Productswith ductless indoor unit LBHB12ARI | 1 ton12,000 Btu/h · Non-ducted | 2.04 | 54% | 8.7 | 17.4 | None | 1 | 213614234 |
Compare LBG Products
LBG Products includes these brand names as listed in AHRI: LBG Products. Standards are checked against published thresholds; program rules beyond ratings are not checked.