- Insights
- Manufacturers
- LENNOX VRF
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
LENNOX VRF heat pump efficiency: 5 outdoor models compared
LENNOX VRF has 5 heat pump outdoor models certified with this refrigerant group, in 10 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes LENNOX VRF makes. LENNOX VRF has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 5
- AHRI certifications
- 10
- Efficiency index
- 40%
- Typical model vs same-size, same-type peers (10 models)
- Meet CEE 2025
- 20%
- 1 model
How LENNOX VRF compares with comparable models
- LENNOX VRF
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index10 models scored | 40% | Not ranked | — |
| COP at 5°F10 models scored | 42% | Not ranked | 2.20 |
| Capacity retention at 5°F10 models scored | 10% | Not ranked | 50% |
| HSPF210 models scored | 45% | Not ranked | 9.8 |
| SEER210 models scored | 63% | Not ranked | 20.0 |
| EER210 models scored | 33% | Not ranked | 10.5 |
| Heating capacity at 5°F10 models scored | 20% | Not ranked | 21,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 20% | 1 |
| CEE 2026 Tier 1 (Split ASHP) | 20% | 1 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- LENNOX VRF (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, 2 tons | 1 | 37% | 3% | 33% | 80% |
| Ducted, 2.5–3 tons | 2 | 35% | 22% | 32% | 72% |
| Ducted, 3.5–4.5 tons | 1 | 41% | 41% | 60% | 70% |
| Ducted, 5 tons and up | 1 | 52% | 41% | 60% | 96% |
| Non-ducted, 2 tons | 1 | 20% | 26% | 22% | 16% |
| Non-ducted, 2.5–3 tons | 2 | 42% | 49% | 51% | 49% |
| Non-ducted, 3.5–4.5 tons | 1 | 61% | 95% | 68% | 86% |
| Non-ducted, 5 tons and up | 1 | 36% | 69% | 42% | 42% |
Every LENNOX VRF model in the market
- LENNOX VRF models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top LENNOX VRF models
Cold-climate picks
No LENNOX VRF model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1VEP036C432P2LENNOX VRF | 3 tons37,600 Btu/h · Non-ducted | 50% | 2.30 | 9.8 | 22.0 | 11.5 | CEE 25CEE 26 | 2 | 206764037 | Non-ducted, 2.5–3 tons | 61.7 | 58.1 | 65.3 | Not a pick |
| 2VEP048C432P2LENNOX VRF | 4 tons48,000 Btu/h · Non-ducted | 50% | 2.20 | 9.8 | 22.0 | 10.5 | None | 2 | 206764039 | Non-ducted, 3.5–4.5 tons | 61.0 | 54.8 | 67.2 | Not a pick |
| 3VEP060C432P2LENNOX VRF | 5 tons60,000 Btu/h · Ducted | 48% | 1.90 | 8.3 | 18.0 | 9.5 | None | 2 | 206764042 | Ducted, 5 tons and up | 51.7 | 43.0 | 60.4 | Not a pick |
| 4VEP036C432P2LENNOX VRF | 3 tons37,600 Btu/h · Ducted | 48% | 1.80 | 8.0 | 18.0 | 10.6 | None | 2 | 206764038 | Ducted, 2.5–3 tons | 41.8 | 27.2 | 56.4 | Not a pick |
| 5VEP048C432P2LENNOX VRF | 4 tons48,000 Btu/h · Ducted | 48% | 1.90 | 8.3 | 16.0 | 8.8 | None | 2 | 206764040 | Ducted, 3.5–4.5 tons | 41.4 | 40.3 | 42.6 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | VEP036C432P2 | 2.30 | Non-ducted, 2.5–3 tons | 97% | 206764037 |
| Capacity retention at 5°F | VEP060C432P2 | 48% | Ducted, 5 tons and up | 33% | 206764042 |
| HSPF2 | VEP036C432P2 | 9.8 | Non-ducted, 2.5–3 tons | 72% | 206764037 |
| SEER2 | VEP060C432P2 | 18.0 | Ducted, 5 tons and up | 96% | 206764042 |
| EER2 | VEP036C432P2 | 11.5 | Non-ducted, 2.5–3 tons | 56% | 206764037 |
| Heating capacity at 5°F | VEP060C432P2 | 31,000 Btu/h | Ducted, 5 tons and up | 45% | 206764042 |
LENNOX VRF size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | None on this board (0 of 1 models qualify) | 37.2(50 is the typical model of its size class)VEP024C432P1 of 1 models have all five ratings · AHRI 206764034 |
| Ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 41.8(50 is the typical model of its size class)VEP036C432P22 of 2 models have all five ratings · AHRI 206764038 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 1 models qualify) | 41.4(50 is the typical model of its size class)VEP048C432P21 of 1 models have all five ratings · AHRI 206764040 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 51.7(50 is the typical model of its size class)VEP060C432P21 of 1 models have all five ratings · AHRI 206764042 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 19.8(50 is the typical model of its size class)VEP024C432P1 of 1 models have all five ratings · AHRI 206764033 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 61.7(50 is the typical model of its size class)VEP036C432P22 of 2 models have all five ratings · AHRI 206764037 |
| Non-ducted, 3.5–4.5 tons | None on this board (0 of 1 models qualify) | 61.0(50 is the typical model of its size class)VEP048C432P21 of 1 models have all five ratings · AHRI 206764039 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 36.2(50 is the typical model of its size class)VEP060C432P21 of 1 models have all five ratings · AHRI 206764041 |
Newest LENNOX VRF certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| VEP060C432P2LENNOX VRF | 5 tons60,000 Btu/h · Ducted and non-ducted | 1.90 | 48% | 8.3 | 18.0 | None | 2 | 206764042 |
| VEP048C432P2LENNOX VRF | 4 tons48,000 Btu/h · Ducted and non-ducted | 1.90 | 48% | 8.3 | 16.0 | None | 2 | 206764040 |
| VEP036C432P2LENNOX VRF | 3 tons37,600 Btu/h · Ducted and non-ducted | 1.80 | 48% | 8.0 | 18.0 | CEE 25CEE 26 | 2 | 206764038 |
| VEP028C432PLENNOX VRF | 2.5 tons28,000 Btu/h · Ducted and non-ducted | 1.70 | 44% | 7.5 | 16.5 | None | 2 | 206764036 |
| VEP024C432PLENNOX VRF | 2 tons24,000 Btu/h · Ducted and non-ducted | 1.60 | 48% | 7.8 | 18.0 | None | 2 | 206764034 |
Compare LENNOX VRF
LENNOX VRF includes these brand names as listed in AHRI: LENNOX VRF. Standards are checked against published thresholds; program rules beyond ratings are not checked.