Skip to content

Liberty Heating & Air Conditioning heat pump efficiency: 61 outdoor models compared

Liberty Heating & Air Conditioning has 61 heat pump outdoor models certified with this refrigerant group, in 4,414 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Liberty Heating & Air Conditioning makes. Liberty Heating & Air Conditioning has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
61
AHRI certifications
4,414
Efficiency index
44%
Typical model vs same-size, same-type peers (47 models)
Meet CEE 2025
19.7%
12 models

How Liberty Heating & Air Conditioning compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Liberty Heating & Air Conditioning against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of Liberty Heating & Air Conditioning’s own modelsLiberty Heating & Air Conditioning is strongest on EER2 (its typical model beats 58% of comparable models) and weakest on heating capacity at 5°F (22%).
  • Liberty Heating & Air Conditioning
  • Middle half of its models
  • Other ranked manufacturers
Liberty …

Source: AHRI Directory, NEEP · as of

Average peer percentile of Liberty Heating & Air Conditioning’s models
RatingBeats comparable modelsRankRaw median
Efficiency index47 models scored44%Not ranked—
COP at 5°F48 models scored45%Not ranked2.00
Capacity retention at 5°F47 models scored24%Not ranked51%
HSPF261 models scored29%Not ranked7.5
SEER261 models scored42%Not ranked15.2
EER261 models scored58%Not ranked11.2
Heating capacity at 5°F47 models scored22%Not ranked16,900 Btu/h

Standards met

Share of Liberty Heating & Air Conditioning’s models with at least one qualifying certification
StandardShareModels
CEE 2025 Tier 1 (Split ASHP)19.7%12
CEE 2026 Tier 1 (Split ASHP)14.8%9
CEE Advanced Tier (Split ASHP)0%0
Xcel Energy Colorado cold-climate ASHP (2025)9.8%6
DOE Cold Climate Heat Pump Challenge0%0
ENERGY STAR Cold Climate0%0

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Liberty Heating & Air Conditioning’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • Liberty Heating & Air Conditioning (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons440%52%20%30%
Ducted, 2 tons1142%40%29%41%
Ducted, 2.5–3 tons1943%46%27%37%
Ducted, 3.5–4.5 tons2547%45%34%48%
Ducted, 5 tons and up236%56%16%30%

Every Liberty Heating & Air Conditioning model in the market

Liberty Heating & Air Conditioning’s 61 models with a known size and duct type, over the shape of the whole catalog.
Liberty Heating & Air Conditioning models by size and ratingColoured: Liberty Heating & Air Conditioning · grey shapes: all 11,475 models · lines: catalog medians by size
  • Liberty Heating & Air Conditioning models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 61 liberty heating & air conditioning models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top Liberty Heating & Air Conditioning models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 Liberty Heating & Air Conditioning cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1ASZS60421EA*Liberty Heating & Air Conditioning · ASZS6with indoor coil CA*EA6030*4A and furnace G*VC801005C*A3.5 tons40,000 Btu/h · Ducted77%2.208.630,60017.0CEE 25CEE 26Xcel25214389647Ducted, 3.5–4.5 tons72.9
2ASZS60361EA*Liberty Heating & Air Conditioning · ASZS6with ducted air handler CA*EA6030*4A*+MBVK20DP1X00A3 tons34,200 Btu/h · Ducted88%2.008.630,00017.5CEE 25CEE 26Xcel35214389643Ducted, 2.5–3 tons69.9
3ASZS60481EA*Liberty Heating & Air Conditioning · ASZS6with ducted air handler AHVE60DP1400B3.5 tons44,000 Btu/h · Ducted70%2.008.631,00017.0CEE 25CEE 26Xcel25214389636Ducted, 3.5–4.5 tons66.5
4ASZS60241EA*Liberty Heating & Air Conditioning · ASZS6with ducted air handler AHVE36CP1400B2 tons23,000 Btu/h · Ducted70%2.008.616,10017.0CEE 25CEE 26Xcel155214389633Ducted, 2 tons51.3
5ASZS601810A*Liberty Heating & Air Conditioning · ASZS6with ducted air handler AHVE24BP1400A1.5 tons16,600 Btu/h · Ducted75%2.108.513,00017.5CEE 25CEE 26Xcel130211178339Ducted, up to 1.5 tons51.2

All-around best

Top 5 Liberty Heating & Air Conditioning models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1ASZV902410A*Liberty Heating & Air Conditioning · ASZV9with indoor coil CA*F3743*6D*+TXV and furnace G*VC800604B*A2 tons23,000 Btu/h · Ducted56%2.208.221.512.0CEE 25CEE 2646210693282Ducted, 2 tons68.651.785.4Not a pick
2ASZV903610A*Liberty Heating & Air Conditioning · ASZV9with ducted air handler CA*F3743*6D*+MBVB16CP1X00A*+TX3 tons34,200 Btu/h · Ducted71%1.858.219.012.0CEE 25CEE 26Xcel102213815106Ducted, 2.5–3 tons68.550.986.150.9
3GSZC704810A*Liberty Heating & Air Conditioning · GSZC7with ducted air handler CAPT4961*4A*+MBVC2001**-1A4 tons47,000 Btu/h · Ducted46%2.008.217.212.5CEE 2546211946593Ducted, 3.5–4.5 tons68.246.789.7Not a pick
4ASZV904810A*Liberty Heating & Air Conditioning · ASZV9with ducted air handler CA*F4961*6D*+MBVC2001**-1A*+TX4 tons45,000 Btu/h · Ducted57%1.828.219.012.0CEE 25CEE 2664210607420Ducted, 3.5–4.5 tons65.740.990.6Not a pick
5GSZC703610A*Liberty Heating & Air Conditioning · GSZC7with ducted air handler CAPTA4230*4A*+MBVC2001**-1A3 tons34,800 Btu/h · Ducted50%2.008.217.212.5CEE 25CEE 2662211946555Ducted, 2.5–3 tons64.244.783.7Not a pick

Best model on each rating

Liberty Heating & Air Conditioning’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FGPHH56041A*2.51Ducted, 5 tons and up94%211946003
Capacity retention at 5°FASZS60361EA*88%Ducted, 2.5–3 tons77%214389643
HSPF2ASZS60421EA*8.6Ducted, 3.5–4.5 tons66%214389635
SEER2ASZV902410A*22.5Ducted, 2 tons99%210693303
EER2GSZB404810A*12.5Ducted, 3.5–4.5 tons92%211946429
Heating capacity at 5°FASZS60361EA*30,000 Btu/hDucted, 2.5–3 tons79%214389634

All 61 Liberty Heating & Air Conditioning models in Explore

Liberty Heating & Air Conditioning size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Liberty Heating & Air Conditioning: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons51.2(50 is the typical model of its size class)ASZS601810A*with ducted air handler AHVE24BP1400A1 of 4 models qualify · AHRI 21117833941.3(50 is the typical model of its size class)ASZS601810A*with ducted air handler AHVE24BP1400A4 of 4 models have all five ratings · AHRI 211178339
Ducted, 2 tons51.3(50 is the typical model of its size class)ASZS60241EA*with ducted air handler AHVE36CP1400B1 of 11 models qualify · AHRI 21438963368.6(50 is the typical model of its size class)ASZV902410A*with indoor coil CA*F3743*6D*+TXV and furnace G*VC800604B*A9 of 11 models have all five ratings · AHRI 210693282
Ducted, 2.5–3 tons69.9(50 is the typical model of its size class)ASZS60361EA*with ducted air handler CA*EA6030*4A*+MBVK20DP1X00A2 of 19 models qualify · AHRI 21438964368.5(50 is the typical model of its size class)ASZV903610A*with ducted air handler CA*F3743*6D*+MBVB16CP1X00A*+TX15 of 19 models have all five ratings · AHRI 213815106
Ducted, 3.5–4.5 tons72.9(50 is the typical model of its size class)ASZS60421EA*with indoor coil CA*EA6030*4A and furnace G*VC801005C*A2 of 25 models qualify · AHRI 21438964768.2(50 is the typical model of its size class)GSZC704810A*with ducted air handler CAPT4961*4A*+MBVC2001**-1A17 of 25 models have all five ratings · AHRI 211946593
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)51.5(50 is the typical model of its size class)GPHH56041A*2 of 2 models have all five ratings · AHRI 211946003

All-around board, every manufacturer

Newest Liberty Heating & Air Conditioning certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Liberty Heating & Air Conditioning outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
ASZS606010A*Liberty Heating & Air Conditioning · ASZS6with indoor coil CA*EA6030*4A and furnace A*VT960804CNA4.5 tons52,500 Btu/h · Ducted1.9959%8.115.2None24217376772
ASZS604210A*Liberty Heating & Air Conditioning · ASZS6with indoor coil CA*EA6030*4A and furnace A*VM971205DNA3.5 tons40,000 Btu/h · Ducted1.9067%8.116.6None32217376766
ASZS603610A*Liberty Heating & Air Conditioning · ASZS6with indoor coil CA*EA3026*4B and furnace G*VM971205DNA3 tons33,200 Btu/h · Ducted1.9057%8.216.3None96217376760
ASZS603010A*Liberty Heating & Air Conditioning · ASZS6with indoor coil CA*EA3026*4B and furnace G*VM971005CNA2.5 tons27,400 Btu/h · Ducted1.9959%8.217.1None154217376749
ASZS602410A*Liberty Heating & Air Conditioning · ASZS6with indoor coil CA*EA2422*4B and furnace G*VM970804CNA2 tons22,200 Btu/h · Ducted1.9960%8.517.3CEE 25130217376731

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Liberty Heating & Air Conditioning

Manufacturers of a similar size, side by side.

Liberty Heating & Air Conditioning includes these brand names as listed in AHRI: Liberty Heating & Air Conditioning. Standards are checked against published thresholds; program rules beyond ratings are not checked.