Skip to content

LLOYD heat pump efficiency: 10 outdoor models compared

LLOYD has 10 heat pump outdoor models certified with this refrigerant group, in 10 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes LLOYD makes. LLOYD has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
10
AHRI certifications
10
Efficiency index
21%
Typical model vs same-size, same-type peers (6 models)
Meet CEE 2025
40%
4 models

How LLOYD compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
LLOYD against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of LLOYD’s own modelsLLOYD is strongest on heating capacity at 5°F (its typical model beats 47% of comparable models) and weakest on HSPF2 (10%).
  • LLOYD
  • Middle half of its models
  • Other ranked manufacturers
LLOYD

Source: AHRI Directory, NEEP · as of

Average peer percentile of LLOYD’s models
RatingBeats comparable modelsRankRaw median
Efficiency index6 models scored21%Not ranked—
COP at 5°F6 models scored14%Not ranked1.79
Capacity retention at 5°F6 models scored38%Not ranked70%
HSPF210 models scored10%Not ranked8.2
SEER210 models scored24%Not ranked19.0
EER210 models scored14%Not ranked10.0
Heating capacity at 5°F6 models scored47%Not ranked10,100 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
LLOYD’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • LLOYD (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons819%14%9%23%
Non-ducted, 2 tons228%13%12%26%

Every LLOYD model in the market

LLOYD’s 10 models with a known size and duct type, over the shape of the whole catalog.
LLOYD models by size and ratingColoured: LLOYD · grey shapes: all 11,475 models · lines: catalog medians by size
  • LLOYD models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 10 lloyd models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top LLOYD models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 3 LLOYD cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1GSSHAX7488*LLOYDwith ductless indoor unit GSSHAX74871 ton9,000 Btu/h · Non-ducted70%1.808.57,00019.0CEE 25CEE 26Xcel1214731814Non-ducted, up to 1.5 tons26.2
2GSSHAX7496*LLOYDwith ductless indoor unit GSSHAX74952 tons24,000 Btu/h · Non-ducted70%1.788.517,10019.0CEE 25CEE 26Xcel1214731818Non-ducted, 2 tons25.4
3GSSHAX7490*LLOYDwith ductless indoor unit GSSHAX7489Also listed as GSSHAX74921 ton12,000 Btu/h · Non-ducted70%1.758.58,60019.0CEE 25CEE 26Xcel1214731815Non-ducted, up to 1.5 tons23.0

All-around best

Top 5 LLOYD models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1GSSHAX7496*LLOYDwith ductless indoor unit GSSHAX74952 tons24,000 Btu/h · Non-ducted70%1.788.519.010.0CEE 25CEE 26Xcel1214731818Non-ducted, 2 tons27.925.430.525.4
2GSSHAX7488*LLOYDwith ductless indoor unit GSSHAX74871 ton9,000 Btu/h · Non-ducted70%1.808.519.010.0CEE 25CEE 26Xcel1214731814Non-ducted, up to 1.5 tons22.526.218.926.2
3GSSHAX7490*LLOYDwith ductless indoor unit GSSHAX7489Also listed as GSSHAX74921 ton12,000 Btu/h · Non-ducted70%1.758.519.010.0CEE 25CEE 26Xcel1214731815Non-ducted, up to 1.5 tons21.023.018.923.0
4GSSHAX7494*LLOYDwith ductless indoor unit GSSHAX74931.5 tons18,000 Btu/h · Non-ducted67%1.798.519.09.4None1214731817Non-ducted, up to 1.5 tons18.320.915.7Not a pick
5GOS18IH219TALWLLOYDwith ductless indoor unit GOS18IH219TALW1.5 tons18,000 Btu/h · Non-ducted61%1.807.819.09.0None1209439604Non-ducted, up to 1.5 tons14.213.414.9Not a pick

Best model on each rating

LLOYD’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FGOS18IH219TALW1.80Non-ducted, up to 1.5 tons22%209439604
Capacity retention at 5°FGSSHAX7490*Also listed as GSSHAX749270%Non-ducted, up to 1.5 tons46%214731815
HSPF2GSSHAX7496*8.5Non-ducted, 2 tons21%214731818
SEER2GSSHAX7496*19.0Non-ducted, 2 tons35%214731818
EER2GSSHAX7496*10.0Non-ducted, 2 tons25%214731818
Heating capacity at 5°FGSSHAX7494*13,170 Btu/hNon-ducted, up to 1.5 tons79%214731817

All 10 LLOYD models in Explore

LLOYD size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
LLOYD: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons26.2(50 is the typical model of its size class)GSSHAX7488*with ductless indoor unit GSSHAX74873 of 8 models qualify · AHRI 21473181422.5(50 is the typical model of its size class)GSSHAX7488*with ductless indoor unit GSSHAX74875 of 8 models have all five ratings · AHRI 214731814
Non-ducted, 2 tons25.4(50 is the typical model of its size class)GSSHAX7496*with ductless indoor unit GSSHAX74951 of 2 models qualify · AHRI 21473181827.9(50 is the typical model of its size class)GSSHAX7496*with ductless indoor unit GSSHAX74951 of 2 models have all five ratings · AHRI 214731818

All-around board, every manufacturer

Newest LLOYD certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified LLOYD outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
GSSHAX7496*LLOYDwith ductless indoor unit GSSHAX74952 tons24,000 Btu/h · Non-ducted1.7870%8.519.0CEE 25CEE 26Xcel1214731818
GSSHAX7494*LLOYDwith ductless indoor unit GSSHAX74931.5 tons18,000 Btu/h · Non-ducted1.7967%8.519.0None1214731817
GSSHAX7492*LLOYDwith ductless indoor unit GSSHAX74911 ton12,000 Btu/h · Non-ducted1.7570%8.519.0CEE 25CEE 26Xcel1214731816
GSSHAX7490*LLOYDwith ductless indoor unit GSSHAX74891 ton12,000 Btu/h · Non-ducted1.7570%8.519.0CEE 25CEE 26Xcel1214731815
GSSHAX7488*LLOYDwith ductless indoor unit GSSHAX74871 ton9,000 Btu/h · Non-ducted1.8070%8.519.0CEE 25CEE 26Xcel1214731814

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for LLOYD in this group.

Compare LLOYD

Manufacturers of a similar size, side by side.

LLOYD includes these brand names as listed in AHRI: LLOYD. Standards are checked against published thresholds; program rules beyond ratings are not checked.