- Insights
- Manufacturers
- MANUFLOW
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
MANUFLOW heat pump efficiency: 34 outdoor models compared
MANUFLOW has 34 heat pump outdoor models certified with this refrigerant group, in 34 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes MANUFLOW makes. MANUFLOW has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 34
- AHRI certifications
- 34
- Efficiency index
- 56%
- Typical model vs same-size, same-type peers (13 models)
- Meet CEE 2025
- 35.3%
- 12 models
How MANUFLOW compares with comparable models
- MANUFLOW
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index13 models scored | 56% | Not ranked | — |
| COP at 5°F13 models scored | 34% | Not ranked | 1.80 |
| Capacity retention at 5°F13 models scored | 48% | Not ranked | 70% |
| HSPF234 models scored | 28% | Not ranked | 8.6 |
| SEER234 models scored | 39% | Not ranked | 19.8 |
| EER234 models scored | 50% | Not ranked | 11.7 |
| Heating capacity at 5°F13 models scored | 45% | Not ranked | 8,400 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 35.3% | 12 |
| CEE 2026 Tier 1 (Split ASHP) | 35.3% | 12 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 29.4% | 10 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- MANUFLOW (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 26 | 55% | 30% | 28% | 41% |
| Non-ducted, 2 tons | 6 | 59% | 81% | 22% | 33% |
| Non-ducted, 2.5–3 tons | 2 | — | — | 48% | 30% |
Every MANUFLOW model in the market
- MANUFLOW models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top MANUFLOW models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AS-09UW3SXEDJ(O)MANUFLOWwith ductless indoor unit AS-09UW3SXEDJ(I) | 1 ton9,000 Btu/h · Non-ducted | 89% | 2.05 | 10.5 | 8,050 | 27.5 | CEE 25CEE 26Xcel | 1 | 202021915 | Non-ducted, up to 1.5 tons | 75.7 |
| 2AS-09UR3SXEDJ(O)MANUFLOWwith ductless indoor unit AS-09UR3SXEDJ(I) | 1 ton9,000 Btu/h · Non-ducted | 78% | 2.10 | 10.5 | 7,000 | 27.5 | CEE 25CEE 26Xcel | 1 | 10277956 | Non-ducted, up to 1.5 tons | 75.0 |
| 3AST-24UW3SDBDJ01(O)MANUFLOWwith ductless indoor unit AST-24UW3SDBDJ01(I) | 2 tons23,000 Btu/h · Non-ducted | 89% | 2.13 | 8.6 | 20,500 | 20.5 | CEE 25CEE 26Xcel | 1 | 203446798 | Non-ducted, 2 tons | 64.0 |
| 4AS-12UW3SXADJ(O)MANUFLOWwith ductless indoor unit AS-12UW3SXADJ(I) | 1 ton12,000 Btu/h · Non-ducted | 81% | 1.95 | 9.8 | 9,730 | 23.5 | CEE 25CEE 26Xcel | 1 | 202021916 | Non-ducted, up to 1.5 tons | 63.9 |
| 5AST-18UW3SBBDJ00(O)MANUFLOWwith ductless indoor unit AST-18UW3SBBDJ00(I) | 1.5 tons18,000 Btu/h · Non-ducted | 77% | 1.87 | 8.6 | 13,770 | 22.5 | CEE 25CEE 26Xcel | 1 | 203446797 | Non-ducted, up to 1.5 tons | 43.2 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AS-09UW3SXEDJ(O)MANUFLOWwith ductless indoor unit AS-09UW3SXEDJ(I) | 1 ton9,000 Btu/h · Non-ducted | 89% | 2.05 | 10.5 | 27.5 | 15.5 | CEE 25CEE 26Xcel | 1 | 202021915 | Non-ducted, up to 1.5 tons | 85.4 | 75.7 | 95.1 | 75.7 |
| 2AS-09UR3SXEDJ(O)MANUFLOWwith ductless indoor unit AS-09UR3SXEDJ(I) | 1 ton9,000 Btu/h · Non-ducted | 78% | 2.10 | 10.5 | 27.5 | 15.5 | CEE 25CEE 26Xcel | 1 | 10277956 | Non-ducted, up to 1.5 tons | 85.1 | 75.0 | 95.1 | 75.0 |
| 3AS-12UW3SXADJ(O)MANUFLOWwith ductless indoor unit AS-12UW3SXADJ(I) | 1 ton12,000 Btu/h · Non-ducted | 81% | 1.95 | 9.8 | 23.5 | 15.4 | CEE 25CEE 26Xcel | 1 | 202021916 | Non-ducted, up to 1.5 tons | 75.3 | 63.9 | 86.7 | 63.9 |
| 4AS-12UR3SXADJ(O)MANUFLOWwith ductless indoor unit AS-12UR3SXADJ(I) | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.75 | 9.8 | 23.5 | 15.4 | CEE 25CEE 26Xcel | 1 | 10277957 | Non-ducted, up to 1.5 tons | 61.7 | 36.7 | 86.7 | 36.7 |
| 5AST-24UW3SDBDJ01(O)MANUFLOWwith ductless indoor unit AST-24UW3SDBDJ01(I) | 2 tons23,000 Btu/h · Non-ducted | 89% | 2.13 | 8.6 | 20.5 | 12.2 | CEE 25CEE 26Xcel | 1 | 203446798 | Non-ducted, 2 tons | 58.5 | 64.0 | 53.1 | 64.0 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | AST-24UW3SDBDJ01(O) | 2.13 | Non-ducted, 2 tons | 81% | 203446798 |
| Capacity retention at 5°F | AS-09UW3SXEDJ(O) | 89% | Non-ducted, up to 1.5 tons | 73% | 202021915 |
| HSPF2 | AS-09UR3SXEDJ(O) | 10.5 | Non-ducted, up to 1.5 tons | 79% | 10277956 |
| SEER2 | AS-09UR3SXEDJ(O) | 27.5 | Non-ducted, up to 1.5 tons | 96% | 10277956 |
| EER2 | AS-09UR3SXEDJ(O) | 15.5 | Non-ducted, up to 1.5 tons | 93% | 10277956 |
| Heating capacity at 5°F | AST-18UW3SBBDJ00(O) | 13,770 Btu/h | Non-ducted, up to 1.5 tons | 83% | 203446797 |
MANUFLOW size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 75.7(50 is the typical model of its size class)AS-09UW3SXEDJ(O)with ductless indoor unit AS-09UW3SXEDJ(I)9 of 26 models qualify · AHRI 202021915 | 85.4(50 is the typical model of its size class)AS-09UW3SXEDJ(O)with ductless indoor unit AS-09UW3SXEDJ(I)12 of 26 models have all five ratings · AHRI 202021915 |
| Non-ducted, 2 tons | 64.0(50 is the typical model of its size class)AST-24UW3SDBDJ01(O)with ductless indoor unit AST-24UW3SDBDJ01(I)1 of 6 models qualify · AHRI 203446798 | 58.5(50 is the typical model of its size class)AST-24UW3SDBDJ01(O)with ductless indoor unit AST-24UW3SDBDJ01(I)1 of 6 models have all five ratings · AHRI 203446798 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | None on this board (0 of 2 models have all five ratings) |
Newest MANUFLOW certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TSC-24HA2/I2XI18Manuflowwith ductless indoor unit TSC-24HA2/I2XI18-I | 2 tons24,000 Btu/h · Non-ducted | — | — | 7.8 | 18.0 | None | 1 | 205234688 |
| TSC-18HA2/I2XI19Manuflowwith ductless indoor unit TSC-18HA2/I2XI19-I | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 61% | 7.8 | 19.0 | None | 1 | 205234687 |
| TSC-12HA1/I2XI20Manuflowwith ductless indoor unit TSC-12HA1/I2XI20-I | 1 ton12,000 Btu/h · Non-ducted | — | — | 7.8 | 19.0 | None | 1 | 205234686 |
| AST-09UW3SVGDJ01(I)MANUFLOWwith ductless indoor unit AST-09UW3SVGDJ01(O) | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 70% | 9.0 | 22.0 | CEE 25CEE 26Xcel | 1 | 203742098 |
| AST-12UW3SXEDJ01(O)MANUFLOWwith ductless indoor unit AST-12UW3SXEDJ01(I) | 1 ton12,000 Btu/h · Non-ducted | 1.75 | 70% | 9.5 | 21.0 | CEE 25CEE 26Xcel | 1 | 203446805 |
Compare MANUFLOW
MANUFLOW includes these brand names as listed in AHRI: MANUFLOW. Standards are checked against published thresholds; program rules beyond ratings are not checked.