Skip to content

MAPLE HEAT heat pump efficiency: 3 outdoor models compared

MAPLE HEAT has 3 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes MAPLE HEAT makes. MAPLE HEAT has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
3
AHRI certifications
5
Efficiency index
55%
Typical model vs same-size, same-type peers (3 models)
Meet CEE 2025
66.7%
2 models

How MAPLE HEAT compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
MAPLE HEAT against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of MAPLE HEAT’s own modelsMAPLE HEAT is strongest on HSPF2 (its typical model beats 66% of comparable models) and weakest on COP at 5°F (32%).
  • MAPLE HEAT
  • Middle half of its models
  • Other ranked manufacturers
MAPLE HE…

Source: AHRI Directory, NEEP · as of

Average peer percentile of MAPLE HEAT’s models
RatingBeats comparable modelsRankRaw median
Efficiency index3 models scored55%Not ranked—
COP at 5°F3 models scored32%Not ranked1.80
Capacity retention at 5°F3 models scored59%Not ranked100%
HSPF23 models scored66%Not ranked10.4
SEER23 models scored63%Not ranked21.5
EER23 models scored53%Not ranked12.5
Heating capacity at 5°F3 models scored54%Not ranked12,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
MAPLE HEAT’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • MAPLE HEAT (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.902,417 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons355%32%66%63%

Every MAPLE HEAT model in the market

MAPLE HEAT’s 3 models with a known size and duct type, over the shape of the whole catalog.
MAPLE HEAT models by size and ratingColoured: MAPLE HEAT · grey shapes: all 11,475 models · lines: catalog medians by size
  • MAPLE HEAT models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 3 maple heat models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top MAPLE HEAT models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 2 MAPLE HEAT cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1NE-T52-MHEAT3018EMAPLE HEAT · NE-T52 Serieswith ductless indoor unit NE-T52-MHEAT3018I1.5 tons18,000 Btu/h · Non-ducted100%1.8011.318,00021.5CEE 25CEE 26XcelES CC2215402351Non-ducted, up to 1.5 tons67.2
2NE-T52-MHEAT3012EMAPLE HEAT · NE-T52 Serieswith ductless indoor unit NE-T52-MHEAT3012I1 ton12,000 Btu/h · Non-ducted100%1.8010.412,00025.5CEE 25CEE 26XcelES CC2215402352Non-ducted, up to 1.5 tons62.4

All-around best

Top 3 MAPLE HEAT models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1NE-T52-MHEAT3012EMAPLE HEAT · NE-T52 Serieswith ductless indoor unit NE-T52-MHEAT3012I1 ton12,000 Btu/h · Non-ducted100%1.8010.425.514.0CEE 25CEE 26XcelES CC2215402352Non-ducted, up to 1.5 tons75.562.488.662.4
2NE-T52-MHEAT3018EMAPLE HEAT · NE-T52 Serieswith ductless indoor unit NE-T52-MHEAT3018I1.5 tons18,000 Btu/h · Non-ducted100%1.8011.321.512.5CEE 25CEE 26XcelES CC2215402351Non-ducted, up to 1.5 tons59.867.252.567.2
3MAPLEHEAT-12EXTMAPLE HEATwith ductless indoor unit MAPLEHEAT-12INT1 ton12,000 Btu/h · Non-ducted40%1.918.720.810.3None1214609257Non-ducted, up to 1.5 tons29.827.332.4Not a pick

Best model on each rating

MAPLE HEAT’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FMAPLEHEAT-12EXT1.91Non-ducted, up to 1.5 tons52%214609257
Capacity retention at 5°FNE-T52-MHEAT3018E100%Non-ducted, up to 1.5 tons83%215402351
HSPF2NE-T52-MHEAT3018E11.3Non-ducted, up to 1.5 tons91%215402351
SEER2NE-T52-MHEAT3012E25.5Non-ducted, up to 1.5 tons89%215402352
EER2NE-T52-MHEAT3012E14.0Non-ducted, up to 1.5 tons85%215402352
Heating capacity at 5°FNE-T52-MHEAT3018E18,000 Btu/hNon-ducted, up to 1.5 tons92%215402351

All 3 MAPLE HEAT models in Explore

MAPLE HEAT size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
MAPLE HEAT: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons67.2(50 is the typical model of its size class)NE-T52-MHEAT3018Ewith ductless indoor unit NE-T52-MHEAT3018I2 of 3 models qualify · AHRI 21540235175.5(50 is the typical model of its size class)NE-T52-MHEAT3012Ewith ductless indoor unit NE-T52-MHEAT3012I3 of 3 models have all five ratings · AHRI 215402352

All-around board, every manufacturer

Newest MAPLE HEAT certifications

By AHRI reference number; AHRI issues references in increasing order.
The 3 most recently certified MAPLE HEAT outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
NE-T52-MHEAT3012EMAPLE HEAT · NE-T52 Serieswith ductless indoor unit NE-T52-MHEAT3012I1 ton12,000 Btu/h · Non-ducted1.80100%10.425.5CEE 25CEE 26XcelES CC2217754302
NE-T52-MHEAT3018EMAPLE HEAT · NE-T52 Serieswith ductless indoor unit NE-T52-MHEAT3018I1.5 tons18,000 Btu/h · Non-ducted1.80100%11.321.5CEE 25CEE 26XcelES CC2217754301
MAPLEHEAT-12EXTMAPLE HEATwith ductless indoor unit MAPLEHEAT-12INT1 ton12,000 Btu/h · Non-ducted1.9140%8.720.8None1214609257

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare MAPLE HEAT

Manufacturers of a similar size, side by side.

MAPLE HEAT includes these brand names as listed in AHRI: MAPLE HEAT. Standards are checked against published thresholds; program rules beyond ratings are not checked.