Skip to content

MSH LEGACY heat pump efficiency: 18 outdoor models compared

MSH LEGACY has 18 heat pump outdoor models certified with this refrigerant group, in 1,716 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes MSH LEGACY makes. MSH LEGACY has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
18
AHRI certifications
1,716
Efficiency index
51%
Typical model vs same-size, same-type peers (14 models)
Meet CEE 2025
0%
0 models

How MSH LEGACY compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
MSH LEGACY against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of MSH LEGACY’s own modelsMSH LEGACY is strongest on EER2 (its typical model beats 91% of comparable models) and weakest on capacity retention at 5°F (16%).
  • MSH LEGACY
  • Middle half of its models
  • Other ranked manufacturers
MSH LEGA…

Source: AHRI Directory, NEEP · as of

Average peer percentile of MSH LEGACY’s models
RatingBeats comparable modelsRankRaw median
Efficiency index14 models scored51%Not ranked—
COP at 5°F14 models scored78%Not ranked2.22
Capacity retention at 5°F14 models scored16%Not ranked47%
HSPF214 models scored33%Not ranked7.5
SEER214 models scored29%Not ranked15.0
EER214 models scored91%Not ranked12.5
Heating capacity at 5°F14 models scored17%Not ranked16,600 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
MSH LEGACY’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • MSH LEGACY (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons241%62%12%24%
Ducted, 2 tons253%76%45%31%
Ducted, 2.5–3 tons451%83%35%25%
Ducted, 3.5–4.5 tons654%82%31%36%
Ducted, 5 tons and up454%82%41%26%

Every MSH LEGACY model in the market

MSH LEGACY’s 18 models with a known size and duct type, over the shape of the whole catalog.
MSH LEGACY models by size and ratingColoured: MSH LEGACY · grey shapes: all 11,475 models · lines: catalog medians by size
  • MSH LEGACY models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 18 msh legacy models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top MSH LEGACY models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

No MSH LEGACY model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.

All-around best

Top 5 MSH LEGACY models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1N4H5S42*K*AAA*MSH LEGACY · PERFORMANCE 15 SEER2 HPwith ducted air handler FXM4X48**ALAlso listed as R4H5S42*K*AAA3.5 tons41,500 Btu/h · Ducted49%2.267.815.212.5None173209693273Ducted, 3.5–4.5 tons60.749.372.0Not a pick
2N4H5S30*K*AAA*MSH LEGACY · PERFORMANCE 15 SEER2 HPwith ducted air handler FMA4X30**ALAlso listed as R4H5S30*K*AAA2.5 tons28,200 Btu/h · Ducted46%2.188.115.212.5None169209692125Ducted, 2.5–3 tons56.146.665.6Not a pick
3N4H5S36*K*AAA*MSH LEGACY · PERFORMANCE 15 SEER2 HPwith indoor coil EA*4X37L21A and furnace *92MSN0802120AAlso listed as R4H5S36*K*AAA3 tons34,600 Btu/h · Ducted46%2.107.815.512.0None186212338000Ducted, 2.5–3 tons54.341.866.8Not a pick
4N4H5S60*K*AAA*MSH LEGACY · PERFORMANCE 15 SEER2 HPwith ducted air handler FJMA4*60L*DAlso listed as R4H5S60*K*AAA5 tons57,000 Btu/h · Ducted50%2.327.514.312.0None14210998915Ducted, 5 tons and up54.051.656.3Not a pick
5N4H5S48*K*AAA*MSH LEGACY · PERFORMANCE 15 SEER2 HPwith ducted air handler FEVA0060**+NAVA46001CKAlso listed as R4H5S48*K*AAA4 tons46,500 Btu/h · Ducted47%2.227.515.012.0None6210538078Ducted, 3.5–4.5 tons53.043.262.9Not a pick

Best model on each rating

MSH LEGACY’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FN4H5S42*K*AAA*Also listed as R4H5S42*K*AAA2.28Ducted, 3.5–4.5 tons83%210838286
Capacity retention at 5°FN4H5S60*K*AAA*Also listed as R4H5S60*K*AAA50%Ducted, 5 tons and up36%210998915
HSPF2N4H5S30*K*AAA*Also listed as R4H5S30*K*AAA8.1Ducted, 2.5–3 tons40%209692125
SEER2N4H5S42*K*AAA*Also listed as R4H5S42*K*AAA15.2Ducted, 3.5–4.5 tons40%209693197
EER2N4H5S42*K*AAA*Also listed as R4H5S42*K*AAA12.5Ducted, 3.5–4.5 tons92%209693197
Heating capacity at 5°FN4H5S60*K*AAA*Also listed as R4H5S60*K*AAA28,400 Btu/hDucted, 5 tons and up31%210998915

All 18 MSH LEGACY models in Explore

MSH LEGACY size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
MSH LEGACY: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 2 models qualify)41.0(50 is the typical model of its size class)N4H5S18*K*AAA*with indoor coil EA*4X25L17A and furnace *80ESU0401712AAlso listed as R4H5S18*K*AAA2 of 2 models have all five ratings · AHRI 210300397
Ducted, 2 tonsNone on this board (0 of 2 models qualify)52.7(50 is the typical model of its size class)N4H5S24*K*AAA*with ducted air handler FMA4X30**ALAlso listed as R4H5S24*K*AAA2 of 2 models have all five ratings · AHRI 210099429
Ducted, 2.5–3 tonsNone on this board (0 of 4 models qualify)56.1(50 is the typical model of its size class)N4H5S30*K*AAA*with ducted air handler FMA4X30**ALAlso listed as R4H5S30*K*AAA4 of 4 models have all five ratings · AHRI 209692125
Ducted, 3.5–4.5 tonsNone on this board (0 of 6 models qualify)60.7(50 is the typical model of its size class)N4H5S42*K*AAA*with ducted air handler FXM4X48**ALAlso listed as R4H5S42*K*AAA4 of 6 models have all five ratings · AHRI 209693273
Ducted, 5 tons and upNone on this board (0 of 4 models qualify)54.0(50 is the typical model of its size class)N4H5S60*K*AAA*with ducted air handler FJMA4*60L*DAlso listed as R4H5S60*K*AAA2 of 4 models have all five ratings · AHRI 210998915

All-around board, every manufacturer

Newest MSH LEGACY certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified MSH LEGACY outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
R4H5S36*K*AAA*MSH LEGACY · 15 SEER2 R SERIES R410A HPwith indoor coil EA*4X48L24A and furnace *80MSU0802120A3 tons34,600 Btu/h · Ducted2.1246%7.815.2None186212348325
N4H5S36*K*AAA*MSH LEGACY · PERFORMANCE 15 SEER2 HPwith indoor coil EA*4X48L24A and furnace *80MSU0802120A3 tons34,600 Btu/h · Ducted2.1246%7.815.2None186212348324
R4H5S30*K*AAA*MSH LEGACY · 15 SEER2 R SERIES R410A HPwith indoor coil EA*4X37L17A and furnace *96MSN0601716A2.5 tons27,200 Btu/h · Ducted2.0446%7.514.3None169212348235
N4H5S30*K*AAA*MSH LEGACY · PERFORMANCE 15 SEER2 HPwith indoor coil EA*4X37L17A and furnace *96MSN0601716A2.5 tons27,200 Btu/h · Ducted2.0446%7.514.3None169212348234
R4H5S24*K*AAA*MSH LEGACY · 15 SEER2 R SERIES R410A HPwith indoor coil EHD4X30AAL and furnace *92MSN1002122A2 tons23,800 Btu/h · Ducted2.1047%7.514.5None72212348189

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for MSH LEGACY in this group.

Compare MSH LEGACY

Manufacturers of a similar size, side by side.

MSH LEGACY includes these brand names as listed in AHRI: MSH LEGACY. Standards are checked against published thresholds; program rules beyond ratings are not checked.