- Insights
- Manufacturers
- Multi MFG
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Multi MFG heat pump efficiency: 54 outdoor models compared
Multi MFG has 54 heat pump outdoor models certified with this refrigerant group, in 100 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Multi MFG makes. Multi MFG has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 54
- AHRI certifications
- 100
- Efficiency index
- 56%
- Typical model vs same-size, same-type peers (70 models)
- Meet CEE 2025
- 70.4%
- 38 models
How Multi MFG compares with comparable models
- Multi MFG
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index70 models scored | 56% | Not ranked | — |
| COP at 5°F70 models scored | 46% | Not ranked | 1.93 |
| Capacity retention at 5°F70 models scored | 59% | Not ranked | 73% |
| HSPF270 models scored | 65% | Not ranked | 9.3 |
| SEER270 models scored | 64% | Not ranked | 19.4 |
| EER270 models scored | 47% | Not ranked | 10.6 |
| Heating capacity at 5°F70 models scored | 58% | Not ranked | 19,700 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 70.4% | 38 |
| CEE 2026 Tier 1 (Split ASHP) | 68.5% | 37 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 55.6% | 30 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 29.6% | 16 |
Sizes and duct types offered
- Multi MFG (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 7 | 62% | 43% | 69% | 71% |
| Ducted, 2 tons | 5 | 61% | 61% | 83% | 70% |
| Ducted, 2.5–3 tons | 10 | 61% | 43% | 74% | 79% |
| Ducted, 3.5–4.5 tons | 10 | 57% | 39% | 81% | 74% |
| Ducted, 5 tons and up | 1 | 42% | 41% | 85% | 35% |
| Non-ducted, up to 1.5 tons | 19 | 50% | 51% | 56% | 48% |
| Non-ducted, 2 tons | 4 | 48% | 46% | 49% | 51% |
| Non-ducted, 2.5–3 tons | 8 | 64% | 50% | 62% | 69% |
| Non-ducted, 3.5–4.5 tons | 6 | 53% | 37% | 43% | 65% |
Every Multi MFG model in the market
- Multi MFG models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top Multi MFG models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MSH-06HD-AMulti MFGwith ductless indoor unit 06HWMS0-C-M-A | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 7,500 | 26.5 | CEE 25CEE 26Xcel | 1 | 214797689 | Non-ducted, up to 1.5 tons | 89.3 |
| 2HHS-18HD-AMulti MFG · HHS Serieswith ducted air handler 18MUC0-HP-A | 1.5 tons18,000 Btu/h · Ducted | 99% | 2.30 | 10.8 | 18,800 | 19.3 | CEE 25CEE 26XcelES CC | 3 | 213156952 | Ducted, up to 1.5 tons | 86.9 |
| 3MSH-48HD-AMulti MFGwith ducted air handler 48HCHP0-C-M-A | 4 tons48,000 Btu/h · Ducted | 88% | 2.02 | 10.3 | 46,000 | 14.3 | None | 2 | 214432058 | Ducted, 3.5–4.5 tons | 86.4 |
| 4MSH-24HD-AMulti MFG · MSH Serieswith ductless indoor unit 24CCHP0-C-M-A | 2 tons24,000 Btu/h · Non-ducted | 103% | 2.00 | 11.5 | 25,800 | 20.5 | CEE 25CEE 26XcelES CC | 3 | 214432056 | Non-ducted, 2 tons | 86.1 |
| 5MSH-36HD-AMulti MFGwith ducted air handler 36HCHP0-C-M-A | 3 tons36,000 Btu/h · Ducted | 86% | 1.98 | 11.0 | 36,000 | 16.5 | None | 2 | 214432057 | Ducted, 2.5–3 tons | 79.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MSH-06HD-AMulti MFGwith ductless indoor unit 06HWMS0-C-M-A | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 26.5 | 15.8 | CEE 25CEE 26Xcel | 1 | 214797689 | Non-ducted, up to 1.5 tons | 92.0 | 89.3 | 94.7 | 89.3 |
| 2MSH-09HD-AMulti MFG · MSH Serieswith ductless indoor unit 9HWMS0-C-M-A | 1 ton9,000 Btu/h · Non-ducted | 88% | 1.97 | 11.5 | 28.1 | 16.2 | CEE 25CEE 26XcelES CC | 3 | 214432059 | Non-ducted, up to 1.5 tons | 87.0 | 76.2 | 97.9 | 76.2 |
| 3MSH-09HD-AMulti MFG · MSH Serieswith ducted air handler 9HCHP0-C-M-A | 1 ton9,000 Btu/h · Ducted | 108% | 1.90 | 12.0 | 20.2 | 13.2 | CEE 25CEE 26XcelES CC | 3 | 214609244 | Ducted, up to 1.5 tons | 85.2 | 74.9 | 95.5 | 74.9 |
| 4MSH-24HD-AMulti MFG · MSH Serieswith ductless indoor unit 24HWMS0-C-M-A | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 21.5 | 13.0 | CEE 25CEE 26XcelES CC | 3 | 214232437 | Non-ducted, 2 tons | 84.3 | 84.5 | 84.1 | 86.1 |
| 536MPC4-HH-AMulti MFG · MPC Series | 3 tons36,000 Btu/h · Non-ducted | 97% | 1.90 | 10.3 | 22.2 | 13.6 | CEE 25CEE 26XcelES CC | 3 | 214232438 | Non-ducted, 2.5–3 tons | 82.8 | 79.3 | 86.4 | 79.3 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | MSH-24HD-A | 2.21 | Non-ducted, 2 tons | 91% | 214232437 |
| Capacity retention at 5°F | 36HPC4-HH-A | 113% | Non-ducted, 2.5–3 tons | 99% | 211120893 |
| HSPF2 | MSH-48HD-A | 10.3 | Ducted, 3.5–4.5 tons | 99% | 214432058 |
| SEER2 | 27MPC3-XX-A | 24.6 | Non-ducted, 2.5–3 tons | 99% | 214797724 |
| EER2 | MSH-09HD-A | 16.2 | Non-ducted, up to 1.5 tons | 98% | 214432059 |
| Heating capacity at 5°F | MSH-36HD-A | 41,000 Btu/h | Non-ducted, 2.5–3 tons | 98% | 214232446 |
Multi MFG size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class)HHS-18HD-Awith ducted air handler 18MUC0-HP-A6 of 7 models qualify · AHRI 213156952 | 85.2(50 is the typical model of its size class)MSH-09HD-Awith ducted air handler 9HCHP0-C-M-A6 of 6 models have all five ratings · AHRI 214609244 |
| Ducted, 2 tons | 79.4(50 is the typical model of its size class)MSH-24HD-Awith ducted air handler 24HCHP0-C-M-A5 of 5 models qualify · AHRI 214609247 | 80.1(50 is the typical model of its size class)MSH-24HD-Awith ducted air handler 24HCHP0-C-M-A5 of 5 models have all five ratings · AHRI 214609247 |
| Ducted, 2.5–3 tons | 79.9(50 is the typical model of its size class)MSH-36HD-Awith ducted air handler 36HCHP0-C-M-A6 of 10 models qualify · AHRI 214432057 | 75.4(50 is the typical model of its size class)27MPC3-XX-A10 of 10 models have all five ratings · AHRI 214797725 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class)MSH-48HD-Awith ducted air handler 48HCHP0-C-M-A6 of 10 models qualify · AHRI 214432058 | 82.0(50 is the typical model of its size class)48MPC5-HH-A11 of 11 models have all five ratings · AHRI 214232442 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 41.7(50 is the typical model of its size class)HES-60HD-Bwith ducted air handler 60MPHP0-M-A1 of 1 models have all five ratings · AHRI 212920477 |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class)MSH-06HD-Awith ductless indoor unit 06HWMS0-C-M-A11 of 19 models qualify · AHRI 214797689 | 92.0(50 is the typical model of its size class)MSH-06HD-Awith ductless indoor unit 06HWMS0-C-M-A19 of 19 models have all five ratings · AHRI 214797689 |
| Non-ducted, 2 tons | 86.1(50 is the typical model of its size class)MSH-24HD-Awith ductless indoor unit 24CCHP0-C-M-A2 of 4 models qualify · AHRI 214432056 | 84.3(50 is the typical model of its size class)MSH-24HD-Awith ductless indoor unit 24HWMS0-C-M-A4 of 4 models have all five ratings · AHRI 214232437 |
| Non-ducted, 2.5–3 tons | 79.3(50 is the typical model of its size class)36MPC4-HH-A4 of 8 models qualify · AHRI 214232438 | 82.8(50 is the typical model of its size class)36MPC4-HH-A8 of 8 models have all five ratings · AHRI 214232438 |
| Non-ducted, 3.5–4.5 tons | 78.2(50 is the typical model of its size class)48MPC5-HH-A4 of 6 models qualify · AHRI 214232441 | 78.8(50 is the typical model of its size class)48MPC5-HH-A6 of 6 models have all five ratings · AHRI 214232441 |
Newest Multi MFG certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| MSH-48HD-AMulti MFGwith ductless indoor unit 48CCHP0-C-M-A | 4 tons48,000 Btu/h · Ducted and non-ducted | 1.98 | 91% | 10.7 | 16.8 | None | 2 | 215441097 |
| 19MPC2-HH-AMulti MFG · MPC Series | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.83 | 100% | 9.6 | 20.5 | CEE 25CEE 26XcelES CC | 3 | 214797738 |
| 55MPC5-XX-AMulti MFG | 4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.75 | 60% | 8.9 | 20.2 | CEE 25 | 3 | 214797735 |
| 48MPC5-XX-AMulti MFG · MPC Series | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.75 | 67% | 9.2 | 22.0 | CEE 25CEE 26 | 3 | 214797732 |
| 36MPC4-XX-AMulti MFG · MPC Series | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.74 | 66% | 9.4 | 22.0 | CEE 25CEE 26 | 3 | 214797729 |
Compare Multi MFG