Skip to content

NAPOLEON heat pump efficiency: 19 outdoor models compared

NAPOLEON has 19 heat pump outdoor models certified with this refrigerant group, in 114 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes NAPOLEON makes. NAPOLEON has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
19
AHRI certifications
114
Efficiency index
63%
Typical model vs same-size, same-type peers (19 models)
Meet CEE 2025
89.5%
17 models

How NAPOLEON compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
NAPOLEON against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of NAPOLEON’s own modelsNAPOLEON is strongest on heating capacity at 5°F (its typical model beats 68% of comparable models) and weakest on EER2 (56%).
  • NAPOLEON
  • Middle half of its models
  • Other ranked manufacturers
NAPOLEON

Source: AHRI Directory, NEEP · as of

Average peer percentile of NAPOLEON’s models
RatingBeats comparable modelsRankRaw median
Efficiency index19 models scored63%Not ranked—
COP at 5°F19 models scored58%Not ranked2.02
Capacity retention at 5°F19 models scored65%Not ranked84%
HSPF220 models scored65%Not ranked9.7
SEER220 models scored64%Not ranked20.0
EER220 models scored56%Not ranked11.8
Heating capacity at 5°F19 models scored68%Not ranked21,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
NAPOLEON’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • NAPOLEON (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, 2 tons161%18%68%65%
Ducted, 2.5 to 3 tons262%54%62%79%
Ducted, 3.5 to 4.5 tons263%58%69%79%
Non-ducted, up to 1.5 tons765%56%73%70%
Non-ducted, 2 tons468%83%74%54%
Non-ducted, 2.5 to 3 tons455%47%43%48%

Every NAPOLEON model in the market

NAPOLEON’s 20 models with a known size and duct type, over the shape of the whole catalog.
NAPOLEON models by size and ratingColoured: NAPOLEON · grey shapes: all 11,706 models · lines: catalog medians by size
  • NAPOLEON models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 20 napoleon models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,706 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1791.701.851.902.102.26
Ducted, 1 ton3541.851.892.002.402.63
Ducted, 1.5 tons8021.751.852.002.202.52
Ducted, 2 tons7911.731.802.002.102.33
Ducted, 2.5 tons7581.701.801.902.102.44
Ducted, 3 tons6741.681.731.902.062.34
Ducted, 3.5 tons6621.611.801.952.202.50
Ducted, 4 tons3731.701.801.912.022.50
Ducted, 4.5 tons5751.701.801.912.082.34
Ducted, 5 tons291.801.801.861.902.10
Non-ducted, 0.5 tons7741.751.801.942.092.19
Non-ducted, 1 ton1,1351.751.801.892.072.24
Non-ducted, 1.5 tons9461.751.801.872.072.20
Non-ducted, 2 tons5981.781.801.832.002.21
Non-ducted, 2.5 tons3271.751.801.841.862.02
Non-ducted, 3 tons5221.801.801.902.002.07
Non-ducted, 3.5 tons711.821.831.902.002.28
Non-ducted, 4 tons2691.801.801.982.002.10
Non-ducted, 4.5 tons1061.771.771.801.972.02
Non-ducted, 5 tons311.892.002.072.302.40

Source: AHRI Directory · as of

NAPOLEON in the cold

From NEEP’s cold-climate listings: 15 NAPOLEON models against all 3,710 listed models.
NAPOLEON capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical NAPOLEON model keeps 77% of its 47°F capacity; the typical listed model keeps 66%.
  • All listed models (median, middle 50% and 80%)
  • NAPOLEON (median, middle 50%)
Heating capacity, % of its 47°F maximum77%COP at maximum capacity1.80

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
NAPOLEON: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
NAPOLEON, 47°F15100%100%100%100%100%
NAPOLEON, 17°F1571%75%80%92%100%
NAPOLEON, 5°F1558%64%77%81%88%
NAPOLEON: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
NAPOLEON, 47°F152.892.963.043.43.4
NAPOLEON, 17°F151.982.022.112.32.49
NAPOLEON, 5°F151.81.81.82.142.24

Source: NEEP ccASHP list · as of

Top NAPOLEON models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 NAPOLEON cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1NDHAS26-24-ONAPOLEON · NDHA Serieswith ductless indoor unit NDHAS26-24-I2 tons24,000 Btu/h · Non-ducted86%2.2111.425,00021.5CEE 25CEE 26XcelES CC1207683236Non-ducted, 2 tons85.5
2NH25-18H-ONAPOLEON · NH Serieswith ductless indoor unit NH25-24F-IAlso listed as NH25-24H-O2 tons21,600 Btu/h · Non-ducted100%2.0710.426,00018.9CEE 25CEE 26XcelES CC2206597272Non-ducted, 2 tons83.8
3NDHAS22-12-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS22-12-I1 ton12,000 Btu/h · Non-ducted74%2.2510.88,82023.1CEE 25CEE 26XcelES CC1207683230Non-ducted, up to 1.5 tons78.7
4NDHAS26-09-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS26-09-I1 ton9,000 Btu/h · Non-ducted88%1.9711.510,60028.1CEE 25CEE 26XcelES CC1207683233Non-ducted, up to 1.5 tons77.3
5NDHAS22-18-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS22-18-I1.5 tons18,000 Btu/h · Non-ducted71%2.3510.512,82924.0CEE 25CEE 26XcelES CC1207683231Non-ducted, up to 1.5 tons76.3

All-around best

Top 5 NAPOLEON models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1NDHAS26-09-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS26-09-I1 ton9,000 Btu/h · Non-ducted88%1.9711.528.116.2CEE 25CEE 26XcelES CC1207683233Non-ducted, up to 1.5 tons87.677.397.977.3
2NDHAS26-24-ONAPOLEON · NDHA Serieswith ductless indoor unit NDHAS26-24-I2 tons24,000 Btu/h · Non-ducted86%2.2111.421.513.0CEE 25CEE 26XcelES CC1207683236Non-ducted, 2 tons84.985.584.385.5
3NDHAS22-18-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS22-18-I1.5 tons18,000 Btu/h · Non-ducted71%2.3510.524.013.5CEE 25CEE 26XcelES CC1207683231Non-ducted, up to 1.5 tons79.376.382.376.3
4NDHAS22-12-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS22-12-I1 ton12,000 Btu/h · Non-ducted74%2.2510.823.113.0CEE 25CEE 26XcelES CC1207683230Non-ducted, up to 1.5 tons76.578.774.378.7
5NDHAS26-12-ONAPOLEON · NDH serieswith ductless indoor unit NDHAS26-12-I1 ton12,000 Btu/h · Non-ducted100%1.8010.425.514.0CEE 25CEE 26XcelES CC1207683234Non-ducted, up to 1.5 tons76.464.088.864.0

Best model on each rating

NAPOLEON’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FNDHAS22-24-O2.22Non-ducted, 2 tons97%207683232
Capacity retention at 5°FNDHAM-36-O101%Non-ducted, 2.5 to 3 tons93%207683243
HSPF2NDHAS26-24-O11.4Non-ducted, 2 tons93%207683236
SEER2NDHAS26-09-O28.1Non-ducted, up to 1.5 tons98%207683233
EER2NDHAS26-09-O16.2Non-ducted, up to 1.5 tons98%207683233
Heating capacity at 5°FNH25-18H-OAlso listed as NH25-24H-O26,000 Btu/hNon-ducted, 2 tons95%206597272

All 19 NAPOLEON models in Explore

NAPOLEON size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
NAPOLEON: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, 2 tonsNo models in this size class60.8(50 is the typical model of its size class)NS18HV24A36with ducted air handler NPFX24AAlso listed as WSEHV2436RA1-N2 of 2 models have all five ratings · AHRI 207335552
Ducted, 2.5 to 3 tons65.0(50 is the typical model of its size class)NDHAM-28-O3 of 3 models qualify · AHRI 20768323973.9(50 is the typical model of its size class)NDHAM-28-O1 of 1 models have all five ratings · AHRI 207683239
Ducted, 3.5 to 4.5 tons60.3(50 is the typical model of its size class)WSEHV4860RA1-Nwith ducted air handler *G52960+TD2 of 2 models qualify · AHRI 21325028063.3(50 is the typical model of its size class)NS18HV48A60with ducted air handler NPFX48AAlso listed as WSEHV4860RA1-N2 of 2 models have all five ratings · AHRI 207335554
Non-ducted, up to 1.5 tons78.7(50 is the typical model of its size class)NDHAS22-12-Owith ductless indoor unit NDHAS22-12-I5 of 7 models qualify · AHRI 20768323087.6(50 is the typical model of its size class)NDHAS26-09-Owith ductless indoor unit NDHAS26-09-I7 of 7 models have all five ratings · AHRI 207683233
Non-ducted, 2 tons85.5(50 is the typical model of its size class)NDHAS26-24-Owith ductless indoor unit NDHAS26-24-I4 of 4 models qualify · AHRI 20768323684.9(50 is the typical model of its size class)NDHAS26-24-Owith ductless indoor unit NDHAS26-24-I4 of 4 models have all five ratings · AHRI 207683236
Non-ducted, 2.5 to 3 tons74.4(50 is the typical model of its size class)NDHAM-36-O2 of 4 models qualify · AHRI 20768324171.5(50 is the typical model of its size class)NDHAM-36-O3 of 4 models have all five ratings · AHRI 207683241

All-around board, every manufacturer

Newest NAPOLEON certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified NAPOLEON outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
WSEHV4860RA1-NNAPOLEONwith ducted air handler A48VHC+TXV+TD4 tons46,500 Btu/h · Ducted1.8069%8.515.2CEE 25CEE 26XcelES CC54216953686
WSEHV2436RA1-NNAPOLEONwith ducted air handler A36VDC+TXV+TD2 tons23,000 Btu/h · Ducted1.8088%8.515.2CEE 25CEE 26XcelES CC36216953685
NS18HV24A36NAPOLEONwith ducted air handler M2430C*1-B*+M2430B*1-EC2 tons26,400 Btu/h · Ducted——7.614.2CEE 25CEE 26XcelES CC3210627710
NDHAM-36-ONAPOLEON3 tons36,000 Btu/h · Non-ducted and mixed (multi-zone)1.80101%9.919.5CEE 25CEE 26XcelES CC2207683243
NDHAM-28-ONAPOLEON2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7690%9.721.3CEE 25CEE 26XcelES CC3207683240

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare NAPOLEON

Manufacturers of a similar size, side by side.

NAPOLEON includes these brand names as listed in AHRI: NAPOLEON. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter