Pioneer heat pump efficiency: 61 outdoor models compared
Pioneer has 61 heat pump outdoor models certified with this refrigerant group, in 98 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Pioneer makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 61
- AHRI certifications
- 98
- Efficiency index
- 52%
- Typical model vs same-size, same-type peers (62 models)
- Meet CEE 2025
- 67.2%
- 41 models
How Pioneer compares with comparable models
- Pioneer
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index62 models scored | 52% | 19th of 27 | — |
| COP at 5°F62 models scored | 47% | 21st of 27 | 1.85 |
| Capacity retention at 5°F62 models scored | 41% | 23rd of 27 | 67% |
| HSPF273 models scored | 52% | 14th of 27 | 9.0 |
| SEER273 models scored | 56% | 11th of 27 | 19.0 |
| EER273 models scored | 43% | 24th of 27 | 11.0 |
| Heating capacity at 5°F62 models scored | 43% | 22nd of 27 | 14,400 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 67.2% | 41 |
| CEE 2026 Tier 1 (Split ASHP) | 62.3% | 38 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 45.9% | 28 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 27.9% | 17 |
Sizes and duct types offered
- Pioneer (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 4 | 69% | 72% | 82% | 77% |
| Ducted, 2 tons | 2 | 65% | 65% | 83% | 71% |
| Ducted, 2.5–3 tons | 8 | 59% | 50% | 69% | 72% |
| Ducted, 3.5–4.5 tons | 6 | 58% | 41% | 80% | 70% |
| Ducted, 5 tons and up | 1 | 75% | 22% | 96% | 96% |
| Non-ducted, up to 1.5 tons | 31 | 48% | 47% | 42% | 51% |
| Non-ducted, 2 tons | 7 | 53% | 39% | 50% | 59% |
| Non-ducted, 2.5–3 tons | 11 | 41% | 39% | 35% | 42% |
| Non-ducted, 3.5–4.5 tons | 3 | 44% | 40% | 46% | 33% |
Every Pioneer model in the market
- Pioneer models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top Pioneer models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1YN009GMFI22RPEPIONEER · YN-serieswith ductless indoor unit CK009GMFILCFHD | 1 ton9,000 Btu/h · Non-ducted | 77% | 2.37 | 11.5 | 8,500 | 22.5 | CEE 25CEE 26XcelES CC | 4 | 213349746 | Non-ducted, up to 1.5 tons | 84.7 |
| 2YN024GMFI22RPEPIONEER · YN serieswith ducted air handler RB024GMFILDFHD | 2 tons23,000 Btu/h · Ducted | 80% | 2.30 | 11.2 | 20,000 | 19.0 | CEE 25CEE 26XcelES CC | 5 | 208141954 | Ducted, 2 tons | 80.3 |
| 3YN018GMFI22RPEPIONEER · YN-serieswith ductless indoor unit FB018GMFILDFHE | 1.5 tons16,000 Btu/h · Non-ducted | 75% | 2.33 | 10.4 | 12,700 | 22.4 | CEE 25CEE 26XcelES CC | 6 | 213349747 | Non-ducted, up to 1.5 tons | 76.8 |
| 4YD060GMFI20MR2PIONEERwith ducted air handler DC060GMFI20HT2 | 4.5 tons52,000 Btu/h · Ducted | 70% | 2.02 | 9.5 | 38,500 | 18.0 | CEE 25CEE 26Xcel | 1 | 205301886 | Ducted, 3.5–4.5 tons | 75.8 |
| 5YH3036GHFD18R2PIONEER · DYR Inverter Pluswith ducted air handler DR036GHFD18HT2 | 3 tons34,000 Btu/h · Ducted | 76% | 2.05 | 9.5 | 26,000 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 207028595 | Ducted, 2.5–3 tons | 75.1 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1YN024GMFI22RPEPIONEER · YN serieswith ducted air handler RB024GMFILDFHD | 2 tons23,000 Btu/h · Ducted | 80% | 2.30 | 11.2 | 19.0 | 12.5 | CEE 25CEE 26XcelES CC | 5 | 208141954 | Ducted, 2 tons | 83.8 | 80.3 | 87.4 | 80.3 |
| 2YN009GHFI25RPHPIONEER · WYF HYPERFORMANCEwith ductless indoor unit WF009GHFI25HLH | 1 ton9,000 Btu/h · Non-ducted | 96% | 1.94 | 10.5 | 25.5 | 14.5 | CEE 25CEE 26XcelES CC | 1 | 211583711 | Non-ducted, up to 1.5 tons | 81.4 | 72.9 | 89.9 | 72.9 |
| 3YD060GMFI20MR2PIONEERwith ducted air handler DC060GMFI20HT2 | 4.5 tons52,000 Btu/h · Ducted | 70% | 2.02 | 9.5 | 18.0 | 11.7 | CEE 25CEE 26Xcel | 1 | 205301886 | Ducted, 3.5–4.5 tons | 79.3 | 75.8 | 82.8 | 75.8 |
| 4YN018GMFI22RPEPIONEER · YN serieswith ducted air handler RB018GMFILDFHD | 1.5 tons17,000 Btu/h · Ducted | 65% | 2.40 | 10.6 | 20.0 | 12.5 | CEE 25CEE 26 | 6 | 208141953 | Ducted, up to 1.5 tons | 78.5 | 68.7 | 88.2 | Not a pick |
| 5YN009GMFI22RPEPIONEER · YN-serieswith ductless indoor unit CK009GMFILCFHD | 1 ton9,000 Btu/h · Non-ducted | 77% | 2.37 | 11.5 | 22.5 | 13.0 | CEE 25CEE 26XcelES CC | 4 | 213349746 | Non-ducted, up to 1.5 tons | 77.2 | 84.7 | 69.8 | 84.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | YN018GMFI22RPE | 2.38 | Non-ducted, up to 1.5 tons | 96% | 208101240 |
| Capacity retention at 5°F | PRB-60HWD1N1-M19 | 70% | Ducted, 5 tons and up | 92% | 212527998 |
| HSPF2 | YN024GMFI22RPE | 11.2 | Ducted, 2 tons | 98% | 208141954 |
| SEER2 | YN030GMFI22M3E | 21.0 | Ducted, 2.5–3 tons | 98% | 208121965 |
| EER2 | YN009GHFI25RPH | 14.5 | Non-ducted, up to 1.5 tons | 89% | 211583711 |
| Heating capacity at 5°F | PRB-60HWD1N1-M19 | 40,000 Btu/h | Ducted, 5 tons and up | 91% | 212527998 |
Pioneer size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 70.4(50 is the typical model of its size class)YN009GMFI22RPEwith ducted air handler RB009GMFILDFHD3 of 4 models qualify · AHRI 208141951 | 78.5(50 is the typical model of its size class)YN018GMFI22RPEwith ducted air handler RB018GMFILDFHD4 of 4 models have all five ratings · AHRI 208141953 |
| Ducted, 2 tons | 80.3(50 is the typical model of its size class)YN024GMFI22RPEwith ducted air handler RB024GMFILDFHD2 of 2 models qualify · AHRI 208141954 | 83.8(50 is the typical model of its size class)YN024GMFI22RPEwith ducted air handler RB024GMFILDFHD2 of 2 models have all five ratings · AHRI 208141954 |
| Ducted, 2.5–3 tons | 75.1(50 is the typical model of its size class)YH3036GHFD18R2with ducted air handler DR036GHFD18HT23 of 8 models qualify · AHRI 207028595 | 76.1(50 is the typical model of its size class)YD036GMFI20MR2with ducted air handler DC036GMFI20HT27 of 8 models have all five ratings · AHRI 205301885 |
| Ducted, 3.5–4.5 tons | 75.8(50 is the typical model of its size class)YD060GMFI20MR2with ducted air handler DC060GMFI20HT22 of 6 models qualify · AHRI 205301886 | 79.3(50 is the typical model of its size class)YD060GMFI20MR2with ducted air handler DC060GMFI20HT25 of 6 models have all five ratings · AHRI 205301886 |
| Ducted, 5 tons and up | 70.2(50 is the typical model of its size class)PRB-60HWD1N1-M191 of 1 models qualify · AHRI 212527998 | 75.1(50 is the typical model of its size class)PRB-60HWD1N1-M191 of 1 models have all five ratings · AHRI 212527998 |
| Non-ducted, up to 1.5 tons | 84.7(50 is the typical model of its size class)YN009GMFI22RPEwith ductless indoor unit CK009GMFILCFHD16 of 31 models qualify · AHRI 213349746 | 81.4(50 is the typical model of its size class)YN009GHFI25RPHwith ductless indoor unit WF009GHFI25HLH27 of 31 models have all five ratings · AHRI 211583711 |
| Non-ducted, 2 tons | 74.2(50 is the typical model of its size class)YN024GMFI22RPEwith ductless indoor unit UB024GMFILCFHD3 of 7 models qualify · AHRI 208141957 | 72.0(50 is the typical model of its size class)YN024GMFI22RPEwith ductless indoor unit UB024GMFILCFHD6 of 7 models have all five ratings · AHRI 208141957 |
| Non-ducted, 2.5–3 tons | 49.3(50 is the typical model of its size class)YN030GMFI22M3E1 of 11 models qualify · AHRI 208121964 | 66.7(50 is the typical model of its size class)YN030GMFI22M3E8 of 11 models have all five ratings · AHRI 208121964 |
| Non-ducted, 3.5–4.5 tons | 56.3(50 is the typical model of its size class)YN048GMFI18RUEwith ductless indoor unit UB048GMFILCFHD1 of 3 models qualify · AHRI 208121960 | 48.3(50 is the typical model of its size class)YN050GMFI22M5E2 of 3 models have all five ratings · AHRI 208121970 |
Newest Pioneer certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| HP36R410APioneerwith ducted air handler THAH-AIRHANDLER36 | 2.5 tons27,600 Btu/h · Ducted | 2.10 | 72% | 8.8 | 17.0 | CEE 25CEE 26Xcel | 1 | 214606643 |
| YN030GLFI19RPEPioneerwith ductless indoor unit WT030GLFI19HLE | 2.5 tons30,000 Btu/h · Non-ducted | 1.80 | 67% | 8.5 | 19.0 | None | 1 | 213350928 |
| YN018GMFI22RPEPIONEER · YN-serieswith ductless indoor unit FB018GMFILDFHE | 1.5 tons16,000 Btu/h · Ducted and non-ducted | 2.33 | 75% | 10.4 | 22.4 | CEE 25CEE 26XcelES CC | 6 | 213349747 |
| YN009GMFI22RPEPIONEER · YN-serieswith ductless indoor unit CK009GMFILCFHD | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.37 | 77% | 11.5 | 22.5 | CEE 25CEE 26XcelES CC | 4 | 213349746 |
| YN012GMFI22RPEPIONEER · YN-serieswith ductless indoor unit CK012GMFILCFHD | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.22 | 62% | 9.8 | 22.0 | CEE 25CEE 26XcelES CC | 5 | 213349745 |