PURE heat pump efficiency: 6 outdoor models compared

PURE has 6 heat pump outdoor models certified with this refrigerant group, in 6 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes PURE makes. PURE has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
6
AHRI certifications
6
Efficiency index
27%
Typical model vs same-size, same-type peers (1 model)
Meet CEE 2025
16.7%
1 model

How PURE compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
PURE against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of PURE’s own modelsPURE is strongest on heating capacity at 5°F (its typical model beats 78% of comparable models) and weakest on HSPF2 (4%).
  • PURE
  • Middle half of its models
  • Other ranked manufacturers
PURE

Source: AHRI Directory, NEEP · as of

Average peer percentile of PURE’s models
RatingBeats comparable modelsRankRaw median
Efficiency index1 model scored27%Not ranked—
COP at 5°F1 model scored22%Not ranked1.80
Capacity retention at 5°F1 model scored23%Not ranked65%
HSPF26 models scored4%Not ranked7.8
SEER26 models scored24%Not ranked19.0
EER26 models scored16%Not ranked10.0
Heating capacity at 5°F1 model scored78%Not ranked13,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
PURE’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • PURE (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons527%22%5%26%
Non-ducted, 2 tons1——2%16%

Every PURE model in the market

PURE’s 6 models with a known size and duct type, over the shape of the whole catalog.
PURE models by size and ratingColoured: PURE · grey shapes: all 11,475 models · lines: catalog medians by size
  • PURE models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 6 pure models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top PURE models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

No PURE model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.

All-around best

Top 1 PURE models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1PIN18H2V51(O)PURE1.5 tons18,000 Btu/h · Non-ducted65%1.808.520.011.0CEE 25CEE 261207236344Non-ducted, up to 1.5 tons27.220.434.0Not a pick

Best model on each rating

PURE’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FPIN18H2V51(O)1.80Non-ducted, up to 1.5 tons22%207236344
Capacity retention at 5°FPIN18H2V51(O)65%Non-ducted, up to 1.5 tons22%207236344
HSPF2PIN18H2V51(O)8.5Non-ducted, up to 1.5 tons16%207236344
SEER2PIN18H2V51(O)20.0Non-ducted, up to 1.5 tons33%207236344
EER2PIN18H2V51(O)11.0Non-ducted, up to 1.5 tons32%207236344
Heating capacity at 5°FPIN18H2V51(O)13,000 Btu/hNon-ducted, up to 1.5 tons78%207236344

All 6 PURE models in Explore

PURE size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
PURE: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tonsNone on this board (0 of 5 models qualify)27.2(50 is the typical model of its size class)PIN18H2V51(O)1 of 5 models have all five ratings · AHRI 207236344
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models have all five ratings)

All-around board, every manufacturer

Newest PURE certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified PURE outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
PIN24H2V51(O)PUREwith ductless indoor unit PIN24H2V51(I)2 tons24,000 Btu/h · Non-ducted——7.818.0None1207236345
PIN18H2V51(O)PURE1.5 tons18,000 Btu/h · Non-ducted1.8065%8.520.0CEE 25CEE 261207236344
PIN12H2V51(O)PUREwith ductless indoor unit PIN12H2V51(I)1 ton12,000 Btu/h · Non-ducted——7.819.0None1207236343
PIN12H1V51(O)PUREwith ductless indoor unit PIN12H1V51(I)1 ton12,000 Btu/h · Non-ducted——7.819.0None1207236342
PIN09H2V51(O)PUREwith ductless indoor unit PIN09H2V51(I)1 ton9,000 Btu/h · Non-ducted——7.819.0None1207236341

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for PURE in this group.

Compare PURE

Manufacturers of a similar size, side by side.

PURE includes these brand names as listed in AHRI: PURE. Standards are checked against published thresholds; program rules beyond ratings are not checked.