QUUL heat pump efficiency: 5 outdoor models compared

QUUL has 5 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes QUUL makes. QUUL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
5
AHRI certifications
5
Efficiency index
44%
Typical model vs same-size, same-type peers (2 models)
Meet CEE 2025
20%
1 model

How QUUL compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
QUUL against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of QUUL’s own modelsQUUL is strongest on COP at 5°F (its typical model beats 73% of comparable models) and weakest on heating capacity at 5°F (22%).
  • QUUL
  • Middle half of its models
  • Other ranked manufacturers
QUUL

Source: AHRI Directory, NEEP · as of

Average peer percentile of QUUL’s models
RatingBeats comparable modelsRankRaw median
Efficiency index2 models scored44%Not ranked—
COP at 5°F2 models scored73%Not ranked1.94
Capacity retention at 5°F2 models scored25%Not ranked61%
HSPF25 models scored29%Not ranked8.2
SEER25 models scored24%Not ranked17.8
EER25 models scored28%Not ranked9.3
Heating capacity at 5°F2 models scored22%Not ranked20,200 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
QUUL’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • QUUL (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, 2.5–3 tons444%73%31%25%
Non-ducted, 3.5–4.5 tons1——22%19%

Every QUUL model in the market

QUUL’s 5 models with a known size and duct type, over the shape of the whole catalog.
QUUL models by size and ratingColoured: QUUL · grey shapes: all 11,475 models · lines: catalog medians by size
  • QUUL models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 5 quul models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top QUUL models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

No QUUL model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.

All-around best

Top 2 QUUL models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1R.Q.I30.OUTQUUL · R.Q serieswith ductless indoor unit R.Q.I302.5 tons30,000 Btu/h · Non-ducted61%1.868.221.012.2CEE 25CEE 261210474669Non-ducted, 2.5–3 tons53.135.770.5Not a pick
2R.Q.I36.OUTQUULwith ductless indoor unit R.Q.I363 tons36,000 Btu/h · Non-ducted61%2.017.818.09.5None1210474670Non-ducted, 2.5–3 tons34.741.328.2Not a pick

Best model on each rating

QUUL’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FR.Q.I36.OUT2.01Non-ducted, 2.5–3 tons87%210474670
Capacity retention at 5°FR.Q.I30.OUT61%Non-ducted, 2.5–3 tons26%210474669
HSPF2R.Q.MOU3610.0Non-ducted, 2.5–3 tons82%205816490
SEER2R.Q.I30.OUT21.0Non-ducted, 2.5–3 tons65%210474669
EER2R.Q.I30.OUT12.2Non-ducted, 2.5–3 tons75%210474669
Heating capacity at 5°FR.Q.I36.OUT22,000 Btu/hNon-ducted, 2.5–3 tons33%210474670

All 5 QUUL models in Explore

QUUL size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
QUUL: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, 2.5–3 tonsNone on this board (0 of 4 models qualify)53.1(50 is the typical model of its size class)R.Q.I30.OUTwith ductless indoor unit R.Q.I302 of 4 models have all five ratings · AHRI 210474669
Non-ducted, 3.5–4.5 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models have all five ratings)

All-around board, every manufacturer

Newest QUUL certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified QUUL outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
R.Q.I36.OUTQUULwith ductless indoor unit R.Q.I363 tons36,000 Btu/h · Non-ducted2.0161%7.818.0None1210474670
R.Q.I30.OUTQUUL · R.Q serieswith ductless indoor unit R.Q.I302.5 tons30,000 Btu/h · Non-ducted1.8661%8.221.0CEE 25CEE 261210474669
R.Q.OS30.OUTQUULwith ductless indoor unit R.Q.OS303 tons36,000 Btu/h · Non-ducted——7.516.0None1206710937
R.Q.MOU48QUULwith ductless indoor unit R.Q.MUE484 tons48,000 Btu/h · Non-ducted——9.017.8None1206188244
R.Q.MOU36QUULwith ductless indoor unit R.Q.MUE363 tons36,000 Btu/h · Non-ducted——10.016.0None1205816490

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for QUUL in this group.

Compare QUUL

Manufacturers of a similar size, side by side.

QUUL includes these brand names as listed in AHRI: QUUL. Standards are checked against published thresholds; program rules beyond ratings are not checked.