- Insights
- Manufacturers
- ROYALTON
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ROYALTON heat pump efficiency: 21 outdoor models compared
ROYALTON has 21 heat pump outdoor models certified with this refrigerant group, in 1,322 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes ROYALTON makes. ROYALTON has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 21
- AHRI certifications
- 1,322
- Efficiency index
- 50%
- Typical model vs same-size, same-type peers (11 models)
- Meet CEE 2025
- 19%
- 4 models
How ROYALTON compares with comparable models
- ROYALTON
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index11 models scored | 50% | Not ranked | — |
| COP at 5°F11 models scored | 58% | Not ranked | 2.18 |
| Capacity retention at 5°F11 models scored | 20% | Not ranked | 50% |
| HSPF221 models scored | 22% | Not ranked | 6.7 |
| SEER221 models scored | 29% | Not ranked | 15.2 |
| EER221 models scored | 67% | Not ranked | 11.4 |
| Heating capacity at 5°F11 models scored | 20% | Not ranked | 17,800 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 19% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 19% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- ROYALTON (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 47% | 73% | 33% | 30% |
| Ducted, 2 tons | 4 | 45% | 38% | 17% | 31% |
| Ducted, 2.5–3 tons | 6 | 53% | 62% | 22% | 29% |
| Ducted, 3.5–4.5 tons | 9 | 48% | 52% | 18% | 28% |
| Ducted, 5 tons and up | 1 | 63% | 90% | 60% | 27% |
Every ROYALTON model in the market
- ROYALTON models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top ROYALTON models
Cold-climate picks
No ROYALTON model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 14HP17L36P-**AROYALTON · 4HP17L Serieswith indoor coil EAD4X-48C+TDR and furnace 80G1DF110CE20 | 3 tons36,000 Btu/h · Ducted | 53% | 2.34 | 8.7 | 16.6 | 13.0 | CEE 25CEE 26 | 232 | 213265391 | Ducted, 2.5–3 tons | 69.9 | 57.2 | 82.7 | Not a pick |
| 24HP17L48P-**AROYALTON · 4HP17L SERIESwith indoor coil EA(C;U)1P60C+TDR+TXV and furnace 80G2UH110CE20 | 4 tons48,000 Btu/h · Ducted | 54% | 2.38 | 8.3 | 15.6 | 13.0 | None | 228 | 210326789 | Ducted, 3.5–4.5 tons | 69.8 | 59.3 | 80.2 | Not a pick |
| 34HP17L42P-**AROYALTON · 4HP17L SERIESwith ducted air handler BCE7E42M*4X | 3.5 tons41,000 Btu/h · Ducted | 55% | 2.18 | 8.3 | 15.6 | 13.0 | None | 203 | 210326870 | Ducted, 3.5–4.5 tons | 68.3 | 56.4 | 80.2 | Not a pick |
| 44HP17L30P-**AROYALTON · 4HP17L Serieswith indoor coil EAD4X-42B+TDR and furnace 80G1DF090BE16 | 2.5 tons29,800 Btu/h · Ducted | 49% | 2.34 | 8.6 | 16.2 | 13.5 | CEE 25CEE 26 | 198 | 213265370 | Ducted, 2.5–3 tons | 67.9 | 54.7 | 81.0 | Not a pick |
| 54HP17L60P-**AROYALTON · 4HP17 SERIESwith indoor coil EA(C;U)1P60C+TDR+TXV and furnace 80G2UH110CE20 | 5 tons57,500 Btu/h · Ducted | 59% | 2.36 | 8.3 | 14.7 | 12.2 | None | 60 | 212619797 | Ducted, 5 tons and up | 67.6 | 72.8 | 62.3 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | 4HP17L30P-**A | 2.36 | Ducted, 2.5–3 tons | 90% | 210327056 |
| Capacity retention at 5°F | 4HP17L60P-**A | 59% | Ducted, 3.5–4.5 tons | 37% | 213859292 |
| HSPF2 | 4HP17L48P-**A | 8.5 | Ducted, 3.5–4.5 tons | 62% | 210326760 |
| SEER2 | 4HP17L36P-**A | 16.8 | Ducted, 2.5–3 tons | 61% | 213308812 |
| EER2 | 4HP17L24P-**A | 14.0 | Ducted, 2 tons | 99% | 211735150 |
| Heating capacity at 5°F | 4HP17L60P-**A | 32,000 Btu/h | Ducted, 5 tons and up | 51% | 212619793 |
ROYALTON size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | 53.6(50 is the typical model of its size class)4HP17L18P-**Awith indoor coil EAD4X-30/36B+TDR and furnace 92G1DF070BE121 of 1 models have all five ratings · AHRI 213265346 |
| Ducted, 2 tons | None on this board (0 of 4 models qualify) | 61.6(50 is the typical model of its size class)4HP17L24P-**Awith indoor coil EAD4X-30/36B+TDR and furnace 80G1DF090BE162 of 4 models have all five ratings · AHRI 213265357 |
| Ducted, 2.5–3 tons | None on this board (0 of 6 models qualify) | 69.9(50 is the typical model of its size class)4HP17L36P-**Awith indoor coil EAD4X-48C+TDR and furnace 80G1DF110CE203 of 6 models have all five ratings · AHRI 213265391 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 9 models qualify) | 69.8(50 is the typical model of its size class)4HP17L48P-**Awith indoor coil EA(C;U)1P60C+TDR+TXV and furnace 80G2UH110CE204 of 9 models have all five ratings · AHRI 210326789 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 67.6(50 is the typical model of its size class)4HP17L60P-**Awith indoor coil EA(C;U)1P60C+TDR+TXV and furnace 80G2UH110CE201 of 1 models have all five ratings · AHRI 212619797 |
Newest ROYALTON certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| 4HP17L60P-**AROYALTON · 4HP17 Serieswith indoor coil 7EH51CX-0*+TDR and furnace 97G2UH090CV12 | 4.5 tons53,500 Btu/h · Ducted | 2.02 | 50% | 7.5 | 14.4 | None | 60 | 214831719 |
| 4HP17L48P-**AROYALTON · 4HP17 Serieswith indoor coil 7EH60DX-0*+TDR and furnace 97G2UH135DV20 | 4 tons48,000 Btu/h · Ducted | 2.18 | 53% | 8.1 | 15.2 | None | 228 | 214831713 |
| 4HP17L42P-**AROYALTON · 4HP17 Serieswith indoor coil 7EH48CX-0*+TDR and furnace 97G2UH110CV20 | 3.5 tons41,000 Btu/h · Ducted | 2.02 | 52% | 7.5 | 14.7 | None | 203 | 214831690 |
| 4HP17L36P-**AROYALTON · 4HP17 Serieswith indoor coil 7EH51CX-0*+TDR and furnace 97G2UH110CV20 | 3 tons36,000 Btu/h · Ducted | 2.18 | 52% | 8.1 | 16.2 | CEE 25CEE 26 | 232 | 214831670 |
| 4HP17L30P-**AROYALTON · 4HP17 Serieswith indoor coil 7EH36CX-0*+TDR and furnace 97G2UH110CV20 | 2.5 tons30,000 Btu/h · Ducted | 2.22 | 52% | 8.5 | 15.2 | CEE 25CEE 26 | 198 | 214831650 |
Compare ROYALTON
ROYALTON includes these brand names as listed in AHRI: ROYALTON. Standards are checked against published thresholds; program rules beyond ratings are not checked.