- Insights
- Manufacturers
- SMARTFLEX
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
SMARTFLEX heat pump efficiency: 11 outdoor models compared
SMARTFLEX has 11 heat pump outdoor models certified with this refrigerant group, in 18 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes SMARTFLEX makes. SMARTFLEX has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 11
- AHRI certifications
- 18
- Efficiency index
- 29%
- Typical model vs same-size, same-type peers (15 models)
- Meet CEE 2025
- 36.4%
- 4 models
How SMARTFLEX compares with comparable models
- SMARTFLEX
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index15 models scored | 29% | Not ranked | — |
| COP at 5°F15 models scored | 19% | Not ranked | 1.80 |
| Capacity retention at 5°F15 models scored | 65% | Not ranked | 74% |
| HSPF215 models scored | 28% | Not ranked | 8.5 |
| SEER215 models scored | 21% | Not ranked | 17.5 |
| EER215 models scored | 19% | Not ranked | 10.2 |
| Heating capacity at 5°F15 models scored | 59% | Not ranked | 21,800 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 36.4% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 36.4% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 63.6% | 7 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- SMARTFLEX (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 22% | 7% | 22% | 17% |
| Ducted, 2 tons | 1 | 28% | 12% | 33% | 18% |
| Ducted, 2.5–3 tons | 1 | 24% | 21% | 30% | 20% |
| Ducted, 3.5–4.5 tons | 1 | 28% | 15% | 39% | 30% |
| Non-ducted, up to 1.5 tons | 6 | 22% | 9% | 23% | 11% |
| Non-ducted, 2 tons | 1 | 55% | 26% | 74% | 47% |
| Non-ducted, 2.5–3 tons | 3 | 41% | 37% | 28% | 36% |
| Non-ducted, 3.5–4.5 tons | 1 | 19% | 38% | 3% | 2% |
Every SMARTFLEX model in the market
- SMARTFLEX models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top SMARTFLEX models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1DHS24CMB22SSMARTFLEX | 2 tons22,000 Btu/h · Non-ducted | 115% | 1.80 | 10.0 | 30,000 | 20.0 | CEE 25CEE 26Xcel | 3 | 207616614 | Non-ducted, 2 tons | 66.1 |
| 2DHS18CMB22SSMARTFLEX | 1.5 tons18,000 Btu/h · Non-ducted | 104% | 1.81 | 10.0 | 21,800 | 20.0 | CEE 25CEE 26Xcel | 2 | 207616612 | Non-ducted, up to 1.5 tons | 64.2 |
| 3DHS24CMB22SSMARTFLEX | 2 tons22,000 Btu/h · Ducted | 108% | 1.75 | 7.8 | 28,000 | 14.5 | None | 3 | 207616615 | Ducted, 2 tons | 45.7 |
| 4DHP36CSB22SSMARTFLEXwith ductless indoor unit DHP36NWB22S | 3 tons33,600 Btu/h · Non-ducted | 71% | 1.85 | 8.5 | 24,400 | 20.0 | CEE 25CEE 26Xcel | 1 | 209818487 | Non-ducted, 2.5–3 tons | 44.1 |
| 5DHS36CMB22SSMARTFLEX | 3 tons36,000 Btu/h · Non-ducted | 78% | 1.82 | 8.6 | 28,200 | 16.0 | Xcel | 3 | 207616617 | Non-ducted, 2.5–3 tons | 43.3 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1DHS24CMB22SSMARTFLEX | 2 tons22,000 Btu/h · Non-ducted | 115% | 1.80 | 10.0 | 20.0 | 12.0 | CEE 25CEE 26Xcel | 3 | 207616614 | Non-ducted, 2 tons | 55.4 | 66.1 | 44.7 | 66.1 |
| 2DHS18CMB22SSMARTFLEX | 1.5 tons18,000 Btu/h · Non-ducted | 104% | 1.81 | 10.0 | 20.0 | 12.0 | CEE 25CEE 26Xcel | 2 | 207616612 | Non-ducted, up to 1.5 tons | 50.6 | 64.2 | 36.9 | 64.2 |
| 3DHP36CSB22SSMARTFLEXwith ductless indoor unit DHP36NWB22S | 3 tons33,600 Btu/h · Non-ducted | 71% | 1.85 | 8.5 | 20.0 | 11.0 | CEE 25CEE 26Xcel | 1 | 209818487 | Non-ducted, 2.5–3 tons | 47.8 | 44.1 | 51.5 | 44.1 |
| 4DHP30CSB22SSMARTFLEXwith ductless indoor unit DHP30NWB22S | 2.5 tons30,000 Btu/h · Non-ducted | 77% | 1.81 | 8.5 | 20.0 | 11.3 | CEE 25CEE 26Xcel | 1 | 209818482 | Non-ducted, 2.5–3 tons | 46.0 | 39.4 | 52.6 | 39.4 |
| 5DHS36CMB22SSMARTFLEX | 3 tons36,000 Btu/h · Non-ducted | 78% | 1.82 | 8.6 | 16.0 | 9.0 | Xcel | 3 | 207616617 | Non-ducted, 2.5–3 tons | 28.2 | 43.3 | 13.2 | 43.3 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | DHP36CSB22S | 1.85 | Non-ducted, 2.5–3 tons | 53% | 209818487 |
| Capacity retention at 5°F | DHS24CMB22S | 115% | Non-ducted, 2 tons | 98% | 207616614 |
| HSPF2 | DHS24CMB22S | 10.0 | Non-ducted, 2 tons | 73% | 207616614 |
| SEER2 | DHP30CSB22S | 20.0 | Non-ducted, 2.5–3 tons | 51% | 209818482 |
| EER2 | DHP30CSB22S | 11.3 | Non-ducted, 2.5–3 tons | 53% | 209818482 |
| Heating capacity at 5°F | DHS18CMB22S | 21,800 Btu/h | Non-ducted, up to 1.5 tons | 99% | 207616612 |
SMARTFLEX size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 35.2(50 is the typical model of its size class)DHS18CMB22S1 of 1 models qualify · AHRI 207616613 | 22.0(50 is the typical model of its size class)DHS18CMB22S1 of 1 models have all five ratings · AHRI 207616613 |
| Ducted, 2 tons | 45.7(50 is the typical model of its size class)DHS24CMB22S1 of 1 models qualify · AHRI 207616615 | 27.7(50 is the typical model of its size class)DHS24CMB22S1 of 1 models have all five ratings · AHRI 207616615 |
| Ducted, 2.5–3 tons | 37.8(50 is the typical model of its size class)DHS36CMB22S1 of 1 models qualify · AHRI 207616618 | 24.1(50 is the typical model of its size class)DHS36CMB22S1 of 1 models have all five ratings · AHRI 207616618 |
| Ducted, 3.5–4.5 tons | 40.5(50 is the typical model of its size class)DHS42CMB22S1 of 1 models qualify · AHRI 207616621 | 28.0(50 is the typical model of its size class)DHS42CMB22S1 of 1 models have all five ratings · AHRI 207616621 |
| Non-ducted, up to 1.5 tons | 64.2(50 is the typical model of its size class)DHS18CMB22S5 of 6 models qualify · AHRI 207616612 | 50.6(50 is the typical model of its size class)DHS18CMB22S6 of 6 models have all five ratings · AHRI 207616612 |
| Non-ducted, 2 tons | 66.1(50 is the typical model of its size class)DHS24CMB22S1 of 1 models qualify · AHRI 207616614 | 55.4(50 is the typical model of its size class)DHS24CMB22S1 of 1 models have all five ratings · AHRI 207616614 |
| Non-ducted, 2.5–3 tons | 44.1(50 is the typical model of its size class)DHP36CSB22Swith ductless indoor unit DHP36NWB22S3 of 3 models qualify · AHRI 209818487 | 47.8(50 is the typical model of its size class)DHP36CSB22Swith ductless indoor unit DHP36NWB22S3 of 3 models have all five ratings · AHRI 209818487 |
| Non-ducted, 3.5–4.5 tons | 31.6(50 is the typical model of its size class)DHS42CMB22S1 of 1 models qualify · AHRI 207616620 | 18.7(50 is the typical model of its size class)DHS42CMB22S1 of 1 models have all five ratings · AHRI 207616620 |
Newest SMARTFLEX certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| DHP36CSB22SSMARTFLEXwith ductless indoor unit DHP36NWB22S | 3 tons33,600 Btu/h · Non-ducted | 1.85 | 71% | 8.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 209818487 |
| DHP30CSB22SSMARTFLEXwith ductless indoor unit DHP30NWB22S | 2.5 tons30,000 Btu/h · Non-ducted | 1.81 | 77% | 8.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 209818482 |
| DHP18CSB22SSMARTFLEXwith ductless indoor unit DHP18NWB22S | 1.5 tons17,400 Btu/h · Non-ducted | 1.75 | 60% | 8.2 | 16.0 | None | 1 | 208495269 |
| DHP12CSB22SSMARTFLEXwith ductless indoor unit DHP12NWB22S | 1 ton11,700 Btu/h · Non-ducted | 1.70 | 72% | 8.5 | 16.5 | None | 1 | 208495264 |
| DHP12CSB12SSMARTFLEXwith ductless indoor unit DHP12NWB12S | 1 ton11,700 Btu/h · Non-ducted | 1.70 | 72% | 8.5 | 16.5 | None | 1 | 208495259 |
Compare SMARTFLEX