Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
TEMPBLUE heat pump efficiency: 10 outdoor models compared
TEMPBLUE has 10 heat pump outdoor models certified with this refrigerant group, in 10 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TEMPBLUE makes. TEMPBLUE has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 10
- AHRI certifications
- 10
- Efficiency index
- 37%
- Typical model vs same-size, same-type peers (9 models)
- Meet CEE 2025
- 50%
- 5 models
How TEMPBLUE compares with comparable models
- TEMPBLUE
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index9 models scored | 37% | Not ranked | — |
| COP at 5°F9 models scored | 50% | Not ranked | 1.85 |
| Capacity retention at 5°F9 models scored | 23% | Not ranked | 62% |
| HSPF210 models scored | 31% | Not ranked | 8.7 |
| SEER210 models scored | 35% | Not ranked | 19.1 |
| EER210 models scored | 34% | Not ranked | 10.4 |
| Heating capacity at 5°F9 models scored | 26% | Not ranked | 15,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 50% | 5 |
| CEE 2026 Tier 1 (Split ASHP) | 40% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- TEMPBLUE (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 4 | 40% | 51% | 40% | 46% |
| Non-ducted, 2 tons | 1 | 22% | 5% | 37% | 27% |
| Non-ducted, 2.5–3 tons | 5 | 37% | 61% | 22% | 29% |
Every TEMPBLUE model in the market
- TEMPBLUE models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top TEMPBLUE models
Cold-climate picks
No TEMPBLUE model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1UTG420B-X009PH3N1HTEMPBLUEwith ductless indoor unit UTH420B-X009-H3N1H | 1 ton9,000 Btu/h · Non-ducted | 69% | 2.14 | 9.4 | 21.7 | 12.6 | CEE 25CEE 26 | 1 | 213614239 | Non-ducted, up to 1.5 tons | 58.2 | 56.8 | 59.6 | Not a pick |
| 2TBG43WX030PH3N1HTEMPBLUEwith ductless indoor unit TBH43WX030-H3N1H | 2.5 tons30,000 Btu/h · Non-ducted | 61% | 1.86 | 8.2 | 21.0 | 12.2 | CEE 25CEE 26 | 1 | 209948222 | Non-ducted, 2.5–3 tons | 53.1 | 35.7 | 70.5 | Not a pick |
| 3UTG420B-X018PH3N1HTEMPBLUEwith ductless indoor unit UTH420B-X018-H3N1H | 1.5 tons18,000 Btu/h · Non-ducted | 64% | 2.18 | 8.7 | 19.5 | 11.0 | CEE 25CEE 26 | 1 | 213614242 | Non-ducted, up to 1.5 tons | 38.6 | 45.4 | 31.8 | Not a pick |
| 4UTG420B-X012PH3N1HTEMPBLUEwith ductless indoor unit UTH420B-X012-H3N1H | 1 ton12,000 Btu/h · Non-ducted | 66% | 1.81 | 9.2 | 21.4 | 10.8 | CEE 25CEE 26 | 1 | 213614240 | Non-ducted, up to 1.5 tons | 38.4 | 36.1 | 40.6 | Not a pick |
| 5TBG43VX030PH3N1HTEMPBLUEwith ductless indoor unit TBH43VX030-H3N1H | 2.5 tons30,000 Btu/h · Non-ducted | 60% | 1.84 | 8.7 | 18.6 | 10.5 | CEE 25 | 1 | 207659294 | Non-ducted, 2.5–3 tons | 35.0 | 32.7 | 37.3 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | TBG43WX036PH3N1H | 2.01 | Non-ducted, 2.5–3 tons | 87% | 209948223 |
| Capacity retention at 5°F | UTG420B-X009PH3N1H | 69% | Non-ducted, up to 1.5 tons | 34% | 213614239 |
| HSPF2 | UTG420B-X009PH3N1H | 9.4 | Non-ducted, up to 1.5 tons | 53% | 213614239 |
| SEER2 | TBG43WX030PH3N1H | 21.0 | Non-ducted, 2.5–3 tons | 65% | 209948222 |
| EER2 | TBG43WX030PH3N1H | 12.2 | Non-ducted, 2.5–3 tons | 75% | 209948222 |
| Heating capacity at 5°F | UTG420B-X018PH3N1H | 12,050 Btu/h | Non-ducted, up to 1.5 tons | 71% | 213614242 |
TEMPBLUE size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | None on this board (0 of 4 models qualify) | 58.2(50 is the typical model of its size class)UTG420B-X009PH3N1Hwith ductless indoor unit UTH420B-X009-H3N1H4 of 4 models have all five ratings · AHRI 213614239 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 21.8(50 is the typical model of its size class)UTG420B-X024PH3N1Hwith ductless indoor unit UTH420B-X024-H3N1H1 of 1 models have all five ratings · AHRI 213614243 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 5 models qualify) | 53.1(50 is the typical model of its size class)TBG43WX030PH3N1Hwith ductless indoor unit TBH43WX030-H3N1H4 of 5 models have all five ratings · AHRI 209948222 |
Newest TEMPBLUE certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| UTG420B-X024PH3N1HTEMPBLUEwith ductless indoor unit UTH420B-X024-H3N1H | 2 tons24,000 Btu/h · Non-ducted | 1.75 | 63% | 8.6 | 18.5 | None | 1 | 213614243 |
| UTG420B-X018PH3N1HTEMPBLUEwith ductless indoor unit UTH420B-X018-H3N1H | 1.5 tons18,000 Btu/h · Non-ducted | 2.18 | 64% | 8.7 | 19.5 | CEE 25CEE 26 | 1 | 213614242 |
| UTG420B-X012PH1N1HTEMPBLUEwith ductless indoor unit UTH420B-X012-H1N1H | 1 ton12,000 Btu/h · Non-ducted | 1.75 | 56% | 8.7 | 20.8 | None | 1 | 213614241 |
| UTG420B-X012PH3N1HTEMPBLUEwith ductless indoor unit UTH420B-X012-H3N1H | 1 ton12,000 Btu/h · Non-ducted | 1.81 | 66% | 9.2 | 21.4 | CEE 25CEE 26 | 1 | 213614240 |
| UTG420B-X009PH3N1HTEMPBLUEwith ductless indoor unit UTH420B-X009-H3N1H | 1 ton9,000 Btu/h · Non-ducted | 2.14 | 69% | 9.4 | 21.7 | CEE 25CEE 26 | 1 | 213614239 |
Compare TEMPBLUE
TEMPBLUE includes these brand names as listed in AHRI: TEMPBLUE. Standards are checked against published thresholds; program rules beyond ratings are not checked.