Skip to content

ThinkAir heat pump efficiency: 4 outdoor models compared

ThinkAir has 4 heat pump outdoor models certified with this refrigerant group, in 4 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes ThinkAir makes. ThinkAir has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
4
AHRI certifications
4
Efficiency index
—
No model has all five ratings
Meet CEE 2025
0%
0 models

How ThinkAir compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
ThinkAir against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of ThinkAir’s own modelsThinkAir is strongest on HSPF2 (its typical model beats 10% of comparable models) and weakest on EER2 (1%).
  • ThinkAir
  • Middle half of its models
  • Other ranked manufacturers
ThinkAir

Source: AHRI Directory, NEEP · as of

Average peer percentile of ThinkAir’s models
RatingBeats comparable modelsRankRaw median
Efficiency index0 models scored—Not ranked—
COP at 5°F0 models scored—Not ranked—
Capacity retention at 5°F0 models scored—Not ranked—
HSPF24 models scored10%Not ranked8.0
SEER24 models scored6%Not ranked17.0
EER24 models scored1%Not ranked8.5
Heating capacity at 5°F0 models scored—Not ranked—

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
ThinkAir’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • ThinkAir (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons3——10%5%
Non-ducted, 2 tons1——8%9%

Every ThinkAir model in the market

ThinkAir’s 4 models with a known size and duct type, over the shape of the whole catalog.
ThinkAir models by size and ratingColoured: ThinkAir · grey shapes: all 11,475 models · lines: catalog medians by size
  • ThinkAir models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 4 thinkair models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top ThinkAir models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

No ThinkAir model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.

All-around best

No ThinkAir model has all five all-around ratings.

Best model on each rating

ThinkAir’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°F—————
Capacity retention at 5°F—————
HSPF2TMES18H1B8.5Non-ducted, up to 1.5 tons16%214783950
SEER2TMES24H1B17.0Non-ducted, 2 tons9%214783951
EER2TMES24H1B8.7Non-ducted, 2 tons2%214783951
Heating capacity at 5°F—————

All 4 ThinkAir models in Explore

ThinkAir size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
ThinkAir: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tonsNone on this board (0 of 3 models qualify)None on this board (0 of 3 models have all five ratings)
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models have all five ratings)

All-around board, every manufacturer

Newest ThinkAir certifications

By AHRI reference number; AHRI issues references in increasing order.
The 4 most recently certified ThinkAir outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
TMES24H1BThinkAirwith ductless indoor unit TMES24H1A2 tons22,000 Btu/h · Non-ducted——8.017.0None1214783951
TMES18H1BThinkAirwith ductless indoor unit TMES18H1A1.5 tons16,500 Btu/h · Non-ducted——8.517.0None1214783950
TMES12H220V1BThinkAirwith ductless indoor unit TMES12H220V1A1 ton11,000 Btu/h · Non-ducted——8.017.0None1213319284
TMES12H1BThinkAirwith ductless indoor unit TMES12H1A1 ton11,000 Btu/h · Non-ducted——8.017.0None1213319283

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for ThinkAir in this group.

Compare ThinkAir

Manufacturers of a similar size, side by side.

ThinkAir includes these brand names as listed in AHRI: ThinkAir. Standards are checked against published thresholds; program rules beyond ratings are not checked.