Skip to content

TK'S heat pump efficiency: 15 outdoor models compared

TK'S has 15 heat pump outdoor models certified with this refrigerant group, in 29 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TK'S makes. TK'S has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
15
AHRI certifications
29
Efficiency index
48%
Typical model vs same-size, same-type peers (22 models)
Meet CEE 2025
66.7%
10 models

How TK'S compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
TK'S against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of TK'S’s own modelsTK'S is strongest on SEER2 (its typical model beats 64% of comparable models) and weakest on capacity retention at 5°F (31%).
  • TK'S
  • Middle half of its models
  • Other ranked manufacturers
TK'S

Source: AHRI Directory, NEEP · as of

Average peer percentile of TK'S’s models
RatingBeats comparable modelsRankRaw median
Efficiency index22 models scored48%Not ranked—
COP at 5°F22 models scored34%Not ranked1.83
Capacity retention at 5°F22 models scored31%Not ranked65%
HSPF222 models scored58%Not ranked9.1
SEER222 models scored64%Not ranked21.1
EER222 models scored47%Not ranked10.8
Heating capacity at 5°F22 models scored38%Not ranked12,600 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
TK'S’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • TK'S (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons259%51%69%68%
Ducted, 2.5–3 tons362%19%75%94%
Ducted, 3.5–4.5 tons264%10%96%95%
Non-ducted, up to 1.5 tons840%49%46%46%
Non-ducted, 2 tons116%13%37%16%
Non-ducted, 2.5–3 tons450%30%57%72%
Non-ducted, 3.5–4.5 tons248%22%47%61%

Every TK'S model in the market

TK'S’s 22 models with a known size and duct type, over the shape of the whole catalog.
TK'S models by size and ratingColoured: TK'S · grey shapes: all 11,475 models · lines: catalog medians by size
  • TK'S models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 22 tk's models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top TK'S models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 3 TK'S cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1T3C-30HFN1*TK'S2.5 tons28,000 Btu/h · Ducted71%1.839.220,00021.0CEE 25CEE 26Xcel3212528010Ducted, 2.5–3 tons57.4
2T2C-18HFN1TK'SAlso listed as T2C-18HFN11.5 tons18,000 Btu/h · Ducted70%2.009.813,30019.0CEE 25CEE 26Xcel3207742406Ducted, up to 1.5 tons52.0
3T3C-30HFN1*TK'S2.5 tons27,000 Btu/h · Non-ducted71%1.839.220,00023.5CEE 25CEE 26Xcel3212528009Non-ducted, 2.5–3 tons49.3

All-around best

Top 5 TK'S models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1T3C-30HFN1*TK'S2.5 tons28,000 Btu/h · Ducted71%1.839.221.011.7CEE 25CEE 26Xcel3212528010Ducted, 2.5–3 tons71.557.485.657.4
2T3C-30HFN1*TK'S2.5 tons27,000 Btu/h · Non-ducted71%1.839.223.512.2CEE 25CEE 26Xcel3212528009Non-ducted, 2.5–3 tons66.749.384.149.3
3T5C-48HFN1TK'SAlso listed as T5C-48HFN14 tons48,000 Btu/h · Ducted66%1.709.720.510.8None3207742412Ducted, 3.5–4.5 tons63.553.573.6Not a pick
4T2C-18HFN1TK'SAlso listed as T2C-18HFN11.5 tons18,000 Btu/h · Ducted70%2.009.819.012.0CEE 25CEE 26Xcel3207742406Ducted, up to 1.5 tons59.452.066.852.0
5T4C-36HFN1TK'SAlso listed as T4C-36HFN13 tons36,000 Btu/h · Ducted65%1.689.220.011.0None3207742409Ducted, 2.5–3 tons56.643.769.4Not a pick

Best model on each rating

TK'S’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FTWS-18HRDN12.18Non-ducted, up to 1.5 tons86%205807088
Capacity retention at 5°FT3C-30HFN1*71%Ducted, 2.5–3 tons55%212528010
HSPF2T5C-48HFN1Also listed as T5C-48HFN19.7Ducted, 3.5–4.5 tons95%207742412
SEER2T3C-30HFN1*21.0Ducted, 2.5–3 tons98%212528010
EER2T3C-30HFN1*12.2Non-ducted, 2.5–3 tons75%212528009
Heating capacity at 5°FT2C-18HFN1Also listed as T2C-18HFN112,900 Btu/hNon-ducted, up to 1.5 tons75%207742407

All 15 TK'S models in Explore

TK'S size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
TK'S: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons52.0(50 is the typical model of its size class)T2C-18HFN1Also listed as T2C-18HFN12 of 2 models qualify · AHRI 20774240659.4(50 is the typical model of its size class)T2C-18HFN1Also listed as T2C-18HFN12 of 2 models have all five ratings · AHRI 207742406
Ducted, 2.5–3 tons57.4(50 is the typical model of its size class)T3C-30HFN1*1 of 3 models qualify · AHRI 21252801071.5(50 is the typical model of its size class)T3C-30HFN1*3 of 3 models have all five ratings · AHRI 212528010
Ducted, 3.5–4.5 tonsNone on this board (0 of 2 models qualify)63.5(50 is the typical model of its size class)T5C-48HFN1Also listed as T5C-48HFN12 of 2 models have all five ratings · AHRI 207742412
Non-ducted, up to 1.5 tonsNone on this board (0 of 8 models qualify)52.0(50 is the typical model of its size class)T2C-18HFN1Also listed as T2C-18HFN18 of 8 models have all five ratings · AHRI 207742405
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)15.9(50 is the typical model of its size class)TWS-24HRDN1with ductless indoor unit TWS-24HRDN11 of 1 models have all five ratings · AHRI 205807089
Non-ducted, 2.5–3 tons49.3(50 is the typical model of its size class)T3C-30HFN1*1 of 4 models qualify · AHRI 21252800966.7(50 is the typical model of its size class)T3C-30HFN1*4 of 4 models have all five ratings · AHRI 212528009
Non-ducted, 3.5–4.5 tonsNone on this board (0 of 2 models qualify)48.3(50 is the typical model of its size class)T5C-48HFN1Also listed as T5C-48HFN12 of 2 models have all five ratings · AHRI 207742411

All-around board, every manufacturer

Newest TK'S certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified TK'S outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
TWS-12ODU-110TK'Swith ductless indoor unit TWS-12IDU-1101 ton12,000 Btu/h · Non-ducted1.7853%8.720.8None1214594918
T5C-48HFN1*TK'S4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7567%9.620.8CEE 25CEE 263212528017
T4C-36HFN1*TK'S3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7465%9.421.6CEE 253212528014
T3C-30HFN1*TK'S2.5 tons27,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8371%9.222.3CEE 25CEE 26Xcel3212528011
T2C-18HFN1*TK'S1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0068%10.020.0CEE 25CEE 26Xcel3212528008

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare TK'S

Manufacturers of a similar size, side by side.

TK'S includes these brand names as listed in AHRI: TK'S. Standards are checked against published thresholds; program rules beyond ratings are not checked.