- Insights
- Manufacturers
- TUTTO KOOL
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
TUTTO KOOL heat pump efficiency: 9 outdoor models compared
TUTTO KOOL has 9 heat pump outdoor models certified with this refrigerant group, in 9 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TUTTO KOOL makes. TUTTO KOOL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 9
- AHRI certifications
- 9
- Efficiency index
- 22%
- Typical model vs same-size, same-type peers (5 models)
- Meet CEE 2025
- 33.3%
- 3 models
How TUTTO KOOL compares with comparable models
- TUTTO KOOL
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index5 models scored | 22% | Not ranked | — |
| COP at 5°F5 models scored | 22% | Not ranked | 1.80 |
| Capacity retention at 5°F5 models scored | 26% | Not ranked | 61% |
| HSPF29 models scored | 10% | Not ranked | 7.8 |
| SEER29 models scored | 24% | Not ranked | 19.0 |
| EER29 models scored | 13% | Not ranked | 9.0 |
| Heating capacity at 5°F5 models scored | 38% | Not ranked | 11,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 33.3% | 3 |
| CEE 2026 Tier 1 (Split ASHP) | 22.2% | 2 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 22.2% | 2 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- TUTTO KOOL (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 5 | 21% | 22% | 8% | 23% |
| Non-ducted, 2 tons | 2 | 25% | 26% | 12% | 26% |
| Non-ducted, 2.5–3 tons | 2 | 23% | 15% | 16% | 25% |
Every TUTTO KOOL model in the market
- TUTTO KOOL models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top TUTTO KOOL models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TK1912E5CA-OTUTTO KOOLwith ductless indoor unit TK1912E5CA-IAlso listed as TK1912E5CD-O | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.80 | 8.5 | 8,600 | 19.0 | CEE 25CEE 26Xcel | 1 | 213244555 | Non-ducted, up to 1.5 tons | 28.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TK1924E5CD-OTUTTO KOOLwith ductless indoor unit TK1924E5CD-I | 2 tons24,000 Btu/h · Non-ducted | 61% | 1.80 | 8.5 | 19.0 | 10.0 | CEE 25 | 1 | 213244557 | Non-ducted, 2 tons | 24.8 | 19.1 | 30.5 | Not a pick |
| 2TK1912E5CA-OTUTTO KOOLwith ductless indoor unit TK1912E5CA-IAlso listed as TK1912E5CD-O | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.80 | 8.5 | 19.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 213244555 | Non-ducted, up to 1.5 tons | 23.6 | 28.4 | 18.9 | 28.4 |
| 3TK1936E5CD-OTUTTO KOOLwith ductless indoor unit TK1936E5CD-I | 3 tons36,000 Btu/h · Non-ducted | 58% | 1.80 | 8.5 | 19.0 | 9.0 | None | 1 | 213244558 | Non-ducted, 2.5–3 tons | 23.4 | 17.9 | 28.8 | Not a pick |
| 4TK1918W5CD-OTUTTO KOOLwith ductless indoor unit TK1918W5CD-I | 1.5 tons18,000 Btu/h · Non-ducted | 61% | 1.80 | 7.8 | 19.0 | 9.0 | None | 1 | 206221821 | Non-ducted, up to 1.5 tons | 14.2 | 13.4 | 14.9 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | TK1924E5CD-O | 1.80 | Non-ducted, 2 tons | 26% | 213244557 |
| Capacity retention at 5°F | TK1912E5CA-OAlso listed as TK1912E5CD-O | 70% | Non-ducted, up to 1.5 tons | 46% | 213244555 |
| HSPF2 | TK1936E5CD-O | 8.5 | Non-ducted, 2.5–3 tons | 25% | 213244558 |
| SEER2 | TK1936E5CD-O | 19.0 | Non-ducted, 2.5–3 tons | 35% | 213244558 |
| EER2 | TK1924E5CD-O | 10.0 | Non-ducted, 2 tons | 25% | 213244557 |
| Heating capacity at 5°F | TK1918W5CD-O | 11,600 Btu/h | Non-ducted, up to 1.5 tons | 61% | 206221821 |
TUTTO KOOL size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 28.4(50 is the typical model of its size class)TK1912E5CA-Owith ductless indoor unit TK1912E5CA-IAlso listed as TK1912E5CD-O2 of 5 models qualify · AHRI 213244555 | 23.6(50 is the typical model of its size class)TK1912E5CA-Owith ductless indoor unit TK1912E5CA-IAlso listed as TK1912E5CD-O3 of 5 models have all five ratings · AHRI 213244555 |
| Non-ducted, 2 tons | None on this board (0 of 2 models qualify) | 24.8(50 is the typical model of its size class)TK1924E5CD-Owith ductless indoor unit TK1924E5CD-I1 of 2 models have all five ratings · AHRI 213244557 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 23.4(50 is the typical model of its size class)TK1936E5CD-Owith ductless indoor unit TK1936E5CD-I1 of 2 models have all five ratings · AHRI 213244558 |
Newest TUTTO KOOL certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TK1936E5CD-OTUTTO KOOLwith ductless indoor unit TK1936E5CD-I | 3 tons36,000 Btu/h · Non-ducted | 1.80 | 58% | 8.5 | 19.0 | None | 1 | 213244558 |
| TK1924E5CD-OTUTTO KOOLwith ductless indoor unit TK1924E5CD-I | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 61% | 8.5 | 19.0 | CEE 25 | 1 | 213244557 |
| TK1912E5CD-OTUTTO KOOLwith ductless indoor unit TK1912E5CD-I | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 213244556 |
| TK1912E5CA-OTUTTO KOOLwith ductless indoor unit TK1912E5CA-I | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 213244555 |
| TK1736W5CD-OTUTTO KOOLwith ductless indoor unit TK1736W5CD-I | 3 tons36,000 Btu/h · Non-ducted | — | — | 7.5 | 17.0 | None | 1 | 206910740 |
Compare TUTTO KOOL
TUTTO KOOL includes these brand names as listed in AHRI: TUTTO KOOL. Standards are checked against published thresholds; program rules beyond ratings are not checked.