- Insights
- Manufacturers
- TUTTOKOOL
Both views use the same certified data. This device remembers your choice.
TUTTOKOOL heat pump efficiency: 31 outdoor models compared
TUTTOKOOL has 31 heat pump outdoor models certified with this refrigerant group, in 126 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TUTTOKOOL makes. TUTTOKOOL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 31
- AHRI certifications
- 126
- Efficiency index
- 29%
- Typical model vs same-size, same-type peers (29 models)
- Meet CEE 2025
- 6.5%
- 2 models
How TUTTOKOOL compares with comparable models
- TUTTOKOOL
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index29 models scored | 29% | Not ranked | — |
| COP at 5°F29 models scored | 12% | Not ranked | 1.65 |
| Capacity retention at 5°F29 models scored | 20% | Not ranked | 41% |
| HSPF237 models scored | 30% | Not ranked | 7.5 |
| SEER237 models scored | 25% | Not ranked | 14.3 |
| EER237 models scored | 51% | Not ranked | 11.5 |
| Heating capacity at 5°F29 models scored | 27% | Not ranked | 17,300 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 6.5% | 2 |
| CEE 2026 Tier 1 (Split ASHP) | 6.5% | 2 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 6.5% | 2 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- TUTTOKOOL (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 3 | 24% | 5% | 21% | 22% |
| Ducted, 2 tons | 5 | 23% | 6% | 25% | 22% |
| Ducted, 2.5 to 3 tons | 9 | 30% | 18% | 28% | 25% |
| Ducted, 3.5 to 4.5 tons | 11 | 31% | 15% | 29% | 25% |
| Ducted, 5 tons and up | 3 | 33% | 7% | 37% | 39% |
| Non-ducted, up to 1.5 tons | 1 | 25% | 0% | 49% | 14% |
| Non-ducted, 2 tons | 1 | 28% | 1% | 54% | 16% |
| Non-ducted, 2.5 to 3 tons | 2 | 37% | 19% | 52% | 25% |
| Non-ducted, 3.5 to 4.5 tons | 1 | 32% | 22% | 31% | 24% |
| Non-ducted, 5 tons and up | 1 | 7% | 3% | 0% | 6% |
Every TUTTOKOOL model in the market
- TUTTOKOOL models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 179 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 354 | 1.85 | 1.89 | 2.00 | 2.40 | 2.63 |
| Ducted, 1.5 tons | 802 | 1.75 | 1.85 | 2.00 | 2.20 | 2.52 |
| Ducted, 2 tons | 791 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 758 | 1.70 | 1.80 | 1.90 | 2.10 | 2.44 |
| Ducted, 3 tons | 674 | 1.68 | 1.73 | 1.90 | 2.06 | 2.34 |
| Ducted, 3.5 tons | 662 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 373 | 1.70 | 1.80 | 1.91 | 2.02 | 2.50 |
| Ducted, 4.5 tons | 575 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 29 | 1.80 | 1.80 | 1.86 | 1.90 | 2.10 |
| Non-ducted, 0.5 tons | 774 | 1.75 | 1.80 | 1.94 | 2.09 | 2.19 |
| Non-ducted, 1 ton | 1,135 | 1.75 | 1.80 | 1.89 | 2.07 | 2.24 |
| Non-ducted, 1.5 tons | 946 | 1.75 | 1.80 | 1.87 | 2.07 | 2.20 |
| Non-ducted, 2 tons | 598 | 1.78 | 1.80 | 1.83 | 2.00 | 2.21 |
| Non-ducted, 2.5 tons | 327 | 1.75 | 1.80 | 1.84 | 1.86 | 2.02 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.80 | 1.90 | 2.00 | 2.07 |
| Non-ducted, 3.5 tons | 71 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 269 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 106 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 31 | 1.89 | 2.00 | 2.07 | 2.30 | 2.40 |
Source: AHRI Directory · as of
Top TUTTOKOOL models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TDV-V48WMN1TTUTTOKOOL | 4 tons48,000 Btu/h · Ducted | 70% | 1.80 | 9.0 | 35,000 | 17.3 | None | 2 | 215427957 | Ducted, 3.5 to 4.5 tons | 54.7 |
| 2TDV-V36WMN1TETUTTOKOOL | 3 tons36,000 Btu/h · Ducted | 70% | 1.80 | 9.2 | 28,000 | 17.7 | CEE 25CEE 26Xcel | 2 | 215427955 | Ducted, 2.5 to 3 tons | 53.2 |
| 3TDV-V36WMN1TETUTTOKOOL | 3 tons36,000 Btu/h · Non-ducted | 70% | 1.80 | 9.4 | 28,000 | 18.5 | CEE 25CEE 26Xcel | 2 | 215427956 | Non-ducted, 2.5 to 3 tons | 44.2 |
| 4TDV-V48WMN1TTUTTOKOOL | 4 tons48,000 Btu/h · Non-ducted | 70% | 1.80 | 9.2 | 35,000 | 18.2 | CEE 25CEE 26Xcel | 2 | 215427958 | Non-ducted, 3.5 to 4.5 tons | 32.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TDV-V36WMN1TETUTTOKOOL | 3 tons36,000 Btu/h · Ducted | 70% | 1.80 | 9.2 | 17.7 | 11.7 | CEE 25CEE 26Xcel | 2 | 215427955 | Ducted, 2.5 to 3 tons | 63.9 | 53.2 | 74.5 | 53.2 |
| 2TDV-V60WMN1TTUTTOKOOL | 5 tons57,500 Btu/h · Ducted | 65% | 1.70 | 8.7 | 17.2 | 8.9 | None | 2 | 215427966 | Ducted, 5 tons and up | 58.3 | 63.8 | 52.8 | Not a pick |
| 3TDV-V48WMN1TTUTTOKOOL | 4 tons48,000 Btu/h · Ducted | 70% | 1.80 | 9.0 | 17.3 | 9.4 | None | 2 | 215427957 | Ducted, 3.5 to 4.5 tons | 53.7 | 54.7 | 52.6 | 54.7 |
| 4TDV-V36WMN1TETUTTOKOOL | 3 tons36,000 Btu/h · Non-ducted | 70% | 1.80 | 9.4 | 18.5 | 11.9 | CEE 25CEE 26Xcel | 2 | 215427956 | Non-ducted, 2.5 to 3 tons | 45.6 | 44.2 | 47.0 | 44.2 |
| 5TDV-V24WMN1TTUTTOKOOL | 2 tons24,400 Btu/h · Ducted | 63% | 1.50 | 8.9 | 17.2 | 10.8 | None | 2 | 215427962 | Ducted, 2 tons | 42.7 | 35.2 | 50.2 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | AHP5030E1000AB | 1.80 | Ducted, 2.5 to 3 tons | 29% | 212920549 |
| Capacity retention at 5°F | TDV-V60WMN1T | 65% | Ducted, 5 tons and up | 82% | 215427966 |
| HSPF2 | TDV-V60WMN1T | 8.7 | Ducted, 5 tons and up | 93% | 215427966 |
| SEER2 | TDV-V60WMN1T | 17.2 | Ducted, 5 tons and up | 92% | 215427966 |
| EER2 | AHP5042E1000A | 12.0 | Ducted, 3.5 to 4.5 tons | 82% | 214717135 |
| Heating capacity at 5°F | TDV-V60WMN1T | 39,000 Btu/h | Ducted, 5 tons and up | 86% | 215427966 |
TUTTOKOOL size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 3 models qualify) | 33.1(50 is the typical model of its size class)TDV-V18WMN1T2 of 3 models have all five ratings · AHRI 215427964 |
| Ducted, 2 tons | None on this board (0 of 5 models qualify) | 42.7(50 is the typical model of its size class)TDV-V24WMN1T4 of 5 models have all five ratings · AHRI 215427962 |
| Ducted, 2.5 to 3 tons | 53.2(50 is the typical model of its size class)TDV-V36WMN1TE1 of 9 models qualify · AHRI 215427955 | 63.9(50 is the typical model of its size class)TDV-V36WMN1TE7 of 9 models have all five ratings · AHRI 215427955 |
| Ducted, 3.5 to 4.5 tons | 54.7(50 is the typical model of its size class)TDV-V48WMN1T1 of 11 models qualify · AHRI 215427957 | 53.7(50 is the typical model of its size class)TDV-V48WMN1T7 of 11 models have all five ratings · AHRI 215427957 |
| Ducted, 5 tons and up | None on this board (0 of 3 models qualify) | 58.3(50 is the typical model of its size class)TDV-V60WMN1T3 of 3 models have all five ratings · AHRI 215427966 |
| Non-ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | 24.6(50 is the typical model of its size class)TDV-V18WMN1T1 of 1 models have all five ratings · AHRI 215427965 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 27.5(50 is the typical model of its size class)TDV-V24WMN1T1 of 1 models have all five ratings · AHRI 215427963 |
| Non-ducted, 2.5 to 3 tons | 44.2(50 is the typical model of its size class)TDV-V36WMN1TE1 of 2 models qualify · AHRI 215427956 | 45.6(50 is the typical model of its size class)TDV-V36WMN1TE2 of 2 models have all five ratings · AHRI 215427956 |
| Non-ducted, 3.5 to 4.5 tons | 32.7(50 is the typical model of its size class)TDV-V48WMN1T1 of 1 models qualify · AHRI 215427958 | 31.9(50 is the typical model of its size class)TDV-V48WMN1T1 of 1 models have all five ratings · AHRI 215427958 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 6.9(50 is the typical model of its size class)TDV-V60WMN1T1 of 1 models have all five ratings · AHRI 215427959 |
Newest TUTTOKOOL certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TDV-V60WMN1TTUTTOKOOL | 5 tons57,500 Btu/h · Ducted and mixed (multi-zone) | 1.70 | 65% | 8.7 | 17.2 | None | 2 | 215427966 |
| TDV-V18WMN1TTUTTOKOOL | 1.5 tons18,200 Btu/h · Ducted and mixed (multi-zone) | 1.45 | 62% | 9.1 | 18.2 | None | 2 | 215427965 |
| TDV-V24WMN1TTUTTOKOOL | 2 tons24,400 Btu/h · Ducted and mixed (multi-zone) | 1.65 | 67% | 9.0 | 18.0 | None | 2 | 215427963 |
| TDV-V36WMN1TTUTTOKOOL | 3 tons36,000 Btu/h · Ducted and mixed (multi-zone) | 1.80 | 53% | 8.9 | 17.9 | None | 2 | 215427961 |
| TDV-V48WMN1TTUTTOKOOL | 4 tons48,000 Btu/h · Ducted and mixed (multi-zone) | 1.80 | 70% | 9.2 | 18.2 | CEE 25CEE 26Xcel | 2 | 215427958 |
Compare TUTTOKOOL
TUTTOKOOL includes these brand names as listed in AHRI: TUTTOKOOL. Standards are checked against published thresholds; program rules beyond ratings are not checked.