- Insights
- Manufacturers
- ULTRA MAXI AIR
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ULTRA MAXI AIR heat pump efficiency: 4 outdoor models compared
ULTRA MAXI AIR has 4 heat pump outdoor models certified with this refrigerant group, in 4 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes ULTRA MAXI AIR makes. ULTRA MAXI AIR has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 4
- AHRI certifications
- 4
- Efficiency index
- 31%
- Typical model vs same-size, same-type peers (4 models)
- Meet CEE 2025
- 25%
- 1 model
How ULTRA MAXI AIR compares with comparable models
- ULTRA MAXI AIR
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index4 models scored | 31% | Not ranked | — |
| COP at 5°F4 models scored | 35% | Not ranked | 1.80 |
| Capacity retention at 5°F4 models scored | 7% | Not ranked | 45% |
| HSPF24 models scored | 38% | Not ranked | 8.9 |
| SEER24 models scored | 42% | Not ranked | 21.1 |
| EER24 models scored | 26% | Not ranked | 10.7 |
| Heating capacity at 5°F4 models scored | 19% | Not ranked | 5,400 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 25% | 1 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- ULTRA MAXI AIR (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 4 | 31% | 35% | 38% | 42% |
Every ULTRA MAXI AIR model in the market
- ULTRA MAXI AIR models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top ULTRA MAXI AIR models
Cold-climate picks
No ULTRA MAXI AIR model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1LSAB-18HRDN1ULTRA MAXI AIRwith ductless indoor unit LSAB-18HRDN1 | 1.5 tons18,000 Btu/h · Non-ducted | 64% | 2.18 | 8.7 | 19.0 | 10.5 | CEE 25 | 1 | 205725746 | Non-ducted, up to 1.5 tons | 34.6 | 45.2 | 23.9 | Not a pick |
| 2LSAB-12HRDN1BULTRA MAXI AIRwith ductless indoor unit LSAB-12HRDN1B | 1 ton12,000 Btu/h · Non-ducted | 40% | 1.91 | 8.7 | 20.8 | 10.3 | None | 1 | 205788536 | Non-ducted, up to 1.5 tons | 29.8 | 27.3 | 32.4 | Not a pick |
| 3LSAB-12HRDN1ULTRA MAXI AIRwith ductless indoor unit LSAB-12HRDN1Also listed as NE-T52-ULTRA12E | 1 ton12,000 Btu/h · Non-ducted | 45% | 1.68 | 9.1 | 21.4 | 10.8 | None | 1 | 205725745 | Non-ducted, up to 1.5 tons | 28.7 | 16.8 | 40.6 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | LSAB-18HRDN1 | 2.18 | Non-ducted, up to 1.5 tons | 86% | 205725746 |
| Capacity retention at 5°F | LSAB-18HRDN1 | 64% | Non-ducted, up to 1.5 tons | 21% | 205725746 |
| HSPF2 | LSAB-12HRDN1Also listed as NE-T52-ULTRA12E | 9.1 | Non-ducted, up to 1.5 tons | 46% | 205725745 |
| SEER2 | LSAB-12HRDN1Also listed as NE-T52-ULTRA12E | 21.4 | Non-ducted, up to 1.5 tons | 49% | 205725745 |
| EER2 | LSAB-12HRDN1Also listed as NE-T52-ULTRA12E | 10.8 | Non-ducted, up to 1.5 tons | 29% | 205725745 |
| Heating capacity at 5°F | LSAB-18HRDN1 | 12,050 Btu/h | Non-ducted, up to 1.5 tons | 71% | 205725746 |
ULTRA MAXI AIR size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | None on this board (0 of 4 models qualify) | 34.6(50 is the typical model of its size class)LSAB-18HRDN1with ductless indoor unit LSAB-18HRDN14 of 4 models have all five ratings · AHRI 205725746 |
Newest ULTRA MAXI AIR certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| NE-T52-ULTRA12EULTRA MAXI AIRwith ductless indoor unit NE-T52-ULTRA12I | 1 ton12,000 Btu/h · Non-ducted | 1.68 | 45% | 9.1 | 21.4 | None | 1 | 214609256 |
| LSAB-12HRDN1BULTRA MAXI AIRwith ductless indoor unit LSAB-12HRDN1B | 1 ton12,000 Btu/h · Non-ducted | 1.91 | 40% | 8.7 | 20.8 | None | 1 | 205788536 |
| LSAB-18HRDN1ULTRA MAXI AIRwith ductless indoor unit LSAB-18HRDN1 | 1.5 tons18,000 Btu/h · Non-ducted | 2.18 | 64% | 8.7 | 19.0 | CEE 25 | 1 | 205725746 |
| LSAB-12HRDN1ULTRA MAXI AIRwith ductless indoor unit LSAB-12HRDN1 | 1 ton12,000 Btu/h · Non-ducted | 1.68 | 45% | 9.1 | 21.4 | None | 1 | 205725745 |
Compare ULTRA MAXI AIR
ULTRA MAXI AIR includes these brand names as listed in AHRI: ULTRA MAXI AIR. Standards are checked against published thresholds; program rules beyond ratings are not checked.